Geometric feature-based multimodal image registration of contrast-enhanced cardiac CT with gated myocardial perfusion SPECT

被引:21
|
作者
Woo, Jonghye [1 ]
Slomka, Piotr J. [1 ]
Dey, Damini [1 ]
Cheng, Victor Y. [1 ]
Hong, Byung-Woo [1 ]
Ramesh, Amit [1 ]
Berman, Daniel S. [1 ]
Karlsberg, Ronald P. [1 ]
Kuo, C. -C. Jay [1 ]
Germano, Guido [1 ]
机构
[1] Cedars Sinai Med Ctr, Dept Imaging, AIM Program, Los Angeles, CA 90048 USA
关键词
multimodal image registration; myocardial perfusion SPECT; coronary CTA; EMISSION COMPUTED-TOMOGRAPHY; EJECTION FRACTION; QUANTIFICATION; VALIDATION; FUSION; SEGMENTATION; QUANTITATION; MOTION;
D O I
10.1118/1.3253301
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Cardiac computed tomography (CT) and single photon emission computed tomography (SPECT) provide clinically complementary information in the diagnosis of coronary artery disease (CAD). Fused anatomical and physiological data acquired sequentially on separate scanners can be coregistered to accurately diagnose CAD in specific coronary vessels. Methods: A fully automated registration method is presented utilizing geometric features from a reliable segmentation of gated myocardial perfusion SPECT (MPS) volumes, where regions of myocardium and blood pools are extracted and used as an anatomical mask to de-emphasize the inhomogeneities of intensity distribution caused by perfusion defects and physiological variations. A multiresolution approach is employed to represent coarse-to-fine details of both volumes. The extracted voxels from each level are aligned using a similarity measure with a piecewise constant image model and minimized using a gradient descent method. The authors then perform limited nonlinear registration of gated MPS to adjust for phase differences by automatic cardiac phase matching between CT and MPS. For phase matching, they incorporate nonlinear registration using thin-plate-spline-based warping. Rigid registration has been compared with manual alignment (n = 45) on 20 stress/rest MPS and coronary CTA data sets acquired from two different sites and five stress CT perfusion data sets. Phase matching was also compared to expert visual assessment. Results: As compared with manual alignment obtained from two expert observers, the mean and standard deviation of absolute registration errors of the proposed method for MPS were 4.3 +/- 3.5, 3.6 +/- 2.6, and 3.6 +/- 2.1 mm for translation and 2.1 +/- 3.2 degrees, 0.3 +/- 0.8 degrees, and 0.7 +/- 1.2 degrees for rotation at site A and 3.8 +/- 2.7, 4.0 +/- 2.9, and 2.2 +/- 1.8 mm for translation and 1.1 +/- 2.0 degrees, 1.6 +/- 3.1 degrees, and 1.9 +/- 3.8 degrees for rotation at site B. The results for CT perfusion were 3.0 +/- 2.9, 3.5 +/- 2.4, and 2.8 +/- 1.0 mm for translation and 3.0 +/- 2.4 degrees, 0.6 +/- 0.9 degrees, and 1.2 +/- 1.3 degrees for rotation. The registration error shows that the proposed method achieves registration accuracy of less than 1 voxel (6.4 x 6.4 x 6.4 mm) misalignment. The proposed method was robust for different initializations in the range from -80 to 70, -80 to 70, and -50 to 50 mm in the x-, y-, and z-axes, respectively. Validation results of finding best matching phase showed that best matching phases were not different by more than two phases, as visually determined. Conclusions: The authors have developed a fast and fully automated method for registration of contrast cardiac CT with gated MPS which includes nonlinear cardiac phase matching and is capable of registering these modalities with accuracy <10 mm in 87% of the cases. (C) 2009 American Association of Physicists in Medicine. [DOI: 10.1118/1.3253301]
引用
收藏
页码:5467 / 5479
页数:13
相关论文
共 50 条
  • [21] Quantitative Myocardial Perfusion with Dynamic Contrast-Enhanced Imaging in MRI and CT: Theoretical Models and Current Implementation
    Pelgrim, G. J.
    Handayani, A.
    Dijkstra, H.
    Prakken, N. H. J.
    Slart, R. H. J. A.
    Oudkerk, M.
    Van Ooijen, P. M. A.
    Vliegenthart, R.
    Sijens, P. E.
    BIOMED RESEARCH INTERNATIONAL, 2016, 2016
  • [22] Cardiac magnetic resonance BOLD and contrast-enhanced perfusion imaging for assessment of myocardial perfusion reserve: a comparison to fractional flow reserve
    Bernhardt, P.
    Manzke, R.
    Walcher, T.
    Rottbauer, W.
    Woehrle, J.
    EUROPEAN HEART JOURNAL, 2011, 32 : 370 - 370
  • [23] Accuracy of Myocardial Blood Flow Estimation From Dynamic Contrast-Enhanced Cardiac CT Compared With PET
    Alessio, Adam M.
    Bindschadler, Michael
    Busey, Janet M.
    Shuman, William P.
    Caldwell, James H.
    Branch, Kelley R.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2019, 12 (06) : e008323
  • [24] A deep-learning approach for myocardial fibrosis detection in early contrast-enhanced cardiac CT images
    Penso, Marco
    Babbaro, Mario
    Moccia, Sara
    Baggiano, Andrea
    Carerj, Maria Ludovica
    Guglielmo, Marco
    Fusini, Laura
    Mushtaq, Saima
    Andreini, Daniele
    Pepi, Mauro
    Pontone, Gianluca
    Caiani, Enrico G. G.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [25] Combining contrast-enhanced ultrasound, CT perfusion and 99mTc-Sestamibi SPECT/CT to guide diagnosis in a case of solid renal tumour
    Kalarakis, Georgios
    Brehmer, Katharina
    Svensson, Anders
    Axelsson, Rimma
    Brismar, Torkel B.
    Tzortzakakis, Antonios
    BJR CASE REPORTS, 2021, 7 (01):
  • [26] Modified dixon-based renal dynamic contrast-enhanced MRI facilitates automated registration and perfusion analysis
    de Boer, Anneloes
    Leiner, Tim
    Vink, Eva E.
    Blankestijn, Peter J.
    van den Berg, Cornelis A. T.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) : 66 - 76
  • [27] Assessment of Cardiac Lead Perforation: Comparison Among Chest Radiography, Transthoracic Echocardiography and Electrocardiography-gated Contrast-enhanced Cardiac CT
    Xiang Zhang
    Chushan Zheng
    Peiwei Wang
    Dongye Wang
    Boshui Huang
    Guozhao Li
    Huijun Hu
    Zehong Yang
    Xiaohui Duan
    Shaoxin Zheng
    Pinming Liu
    Jingfeng Wang
    Jun Shen
    European Radiology, 2019, 29 : 963 - 974
  • [28] Assessment of Cardiac Lead Perforation: Comparison Among Chest Radiography, Transthoracic Echocardiography and Electrocardiography-gated Contrast-enhanced Cardiac CT
    Zhang, Xiang
    Zheng, Chushan
    Wang, Peiwei
    Wang, Dongye
    Huang, Boshui
    Li, Guozhao
    Hu, Huijun
    Yang, Zehong
    Duan, Xiaohui
    Zheng, Shaoxin
    Liu, Pinming
    Wang, Jingfeng
    Shen, Jun
    EUROPEAN RADIOLOGY, 2019, 29 (02) : 963 - 974
  • [29] Contrast-enhanced cine cardiac MR detects impairment of coronary microvascular perfusion in patients after acute myocardial infarct
    Ricardo Loureiro
    Hiram G Bezerra
    Joalbo M Andrade
    Chun-Ho Yun
    Ammar Sarwar
    Michael Bolen
    Thomas J Brady
    Ricardo C Cury
    Journal of Cardiovascular Magnetic Resonance, 11 (Suppl 1)
  • [30] Intravenous contrast-enhanced CT can be used for CT-based attenuation correction in clinical 111In-octreotide SPECT/CT
    Klausen T.L.
    Mortensen J.
    de Nijs R.
    Andersen F.L.
    Højgaard L.
    Beyer T.
    Holm S.
    EJNMMI Physics, 2 (1) : 1 - 13