Inadvertent QRS prolongation by an optimization device-based algorithm in patients with cardiac resynchronization therapy

被引:0
|
作者
Sedlacek, Kamil [1 ,2 ]
Polasek, Rostislav [3 ]
Jansova, Helena [4 ]
Grieco, Domenico [5 ]
Kucera, Pavel [3 ]
Kautzner, Josef [4 ]
Francis, Darrel P. [6 ]
Wichterle, Dan [4 ,7 ]
机构
[1] Univ Hosp, Dept Internal Med Cardiol & Angiol 1, Hradec Kralove, Czech Republic
[2] Charles Univ Prague, Fac Med, Hradec Kralove, Czech Republic
[3] Liberec Reg Hosp, Cardiol Dept, Liberec, Czech Republic
[4] Inst Clin & Expt Med, Dept Cardiol, Prague, Czech Republic
[5] Policlin Casilino Rome, Dept Cardiovasc Sci, Rome, Italy
[6] Imperial Coll London, Hammersmith Hosp, Int Ctr Circulatory Hlth, Natl Heart & Lung Inst, London, England
[7] Charles Univ Prague, Fac Med 1, Dept Internal Cardiovasc Med 2, Prague, Czech Republic
来源
PLOS ONE | 2022年 / 17卷 / 09期
关键词
HEART-FAILURE; DELAY OPTIMIZATION; ATRIOVENTRICULAR DELAY; INTERVAL; MORTALITY;
D O I
10.1371/journal.pone.0275276
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Device-based algorithms offer the potential for automated optimization of cardiac resynchronization therapy (CRT), but the process for accepting them into clinical use is currently still ad-hoc, rather than based on pre-clinical and clinical testing of specific features of validity. We investigated how the QuickOpt-guided VV delay (VVD) programming performs against the clinical and engineering heuristic of QRS complex shortening by CRT. Methods A prospective, 2-center study enrolled 37 consecutive patients with CRT. QRS complex duration (QRSd) was assessed during intrinsic atrioventricular conduction, synchronous biventricular pacing, and biventricular pacing with QuickOpt-proposed VVD. The measurements were done manually by electronic calipers in signal-averaged and magnified 12-lead QRS complexes. Results Native QRSd was 174 +/- 22 ms. Biventricular pacing with empiric AVD and synchronous VVD resulted in QRSd 156 +/- 20 ms, a significant narrowing from the baseline QRSd by 17 +/- 27 ms, P = 0.0003. In 36 of 37 patients, the QuickOpt algorithm recommended left ventricular preexcitation with VVD of 42 +/- 18 ms (median 40 ms; interquartile range 30-55 ms, P < 0.00001). QRSd in biventricular pacing with QuickOpt-based VVD was significantly longer compared with synchronous biventricular pacing (168 +/- 25 ms vs. 156 +/- 20 ms; difference 12 +/- 11ms; P < 0.00001). This prolongation correlated with the absolute VVD value (R = 0.66, P < 0.00001). Conclusions QuickOpt algorithm systematically favours a left-preexcitation VVD which translates into a significant prolongation of the QRSd compared to synchronous biventricular pacing. There is no reason to believe that a manipulation that systematically widens QRSd should be considered to optimize physiology. Device-based CRT optimization algorithms should undergo systematic mechanistic pre-clinical evaluation in various scenarios before they are tested in large clinical studies.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Efficacy of Cardiac Resynchronization Therapy in Patients with a Relatively Narrow QRS Complex
    Wakayama, Yuji
    Fukuda, Koji
    Nakano, Makoto
    Kondo, Masateru
    Shafee, Mohamed Abdel
    Kawana, Akiko
    Hasebe, Yuhi
    Shimokawa, Hiroaki
    JOURNAL OF CARDIAC FAILURE, 2012, 18 (10) : S165 - S165
  • [42] Benefits of cardiac resynchronization therapy for heart failure patients with narrow QRS
    Furugen, Azusa
    Matsuda, Naoki
    Shiga, Tsuyoshi
    Mochida, Asako
    Ashihara, Kyomi
    Shoda, Morio
    Ishizuka, Naoko
    Haginvara, Nobuhisa
    JOURNAL OF CARDIAC FAILURE, 2008, 14 (07) : S176 - S176
  • [43] Cardiac Resynchronization Therapy in Patients With Heart Failure and Narrow QRS Complexes
    Tayal, Bhupendar
    Gorcsan, John, III
    Bax, Jeroen J.
    Risum, Niels
    Olsen, Niels Thue
    Singh, Jagmeet P.
    Abraham, William T.
    Borer, Jeffrey S.
    Dickstein, Kenneth
    Gras, Daniel
    Krum, Henry
    Brugada, Josep
    Robertson, Michele
    Ford, Ian
    Holzmeister, Johannes
    Ruschitzka, Frank
    Sogaard, Peter
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (12) : 1325 - 1333
  • [44] Fragmented QRS, a predictor of clinical events in patients on cardiac resynchronization therapy
    Martinez Milla, J.
    Garcia-Talavera, C.
    Arroyo, B.
    Camblor, A.
    Garcia-Ropero, A.
    Miracle, A.
    Benezet-Mazuecos, J.
    Rubio-Campal, J. M.
    Romero-Daza, A.
    EUROPEAN HEART JOURNAL, 2020, 41 : 798 - 798
  • [45] Cardiac resynchronization therapy in patients with a narrow QRS and evidence of LV dyssynchrony
    Taborsky, M.
    Neuzil, P.
    Schejbalova, M.
    EUROPEAN JOURNAL OF HEART FAILURE, 2007, 6 : 170 - 170
  • [46] Evolution of QRS duration in patients hyper responder to cardiac resynchronization therapy
    Castellant, P.
    Orhan, E.
    Fatemi, M.
    Etienne, Y.
    Bertault-Valls, V.
    Blanc, J. J.
    EUROPEAN HEART JOURNAL, 2009, 30 : 1005 - 1005
  • [47] QRS fragmentation as predictor for reverse remodelling in cardiac resynchronization therapy patients
    Romero Daza, A.
    Garcia Ropero, A.
    Benezet Mazuecos, J.
    Cortes, M.
    Quinones, M. A.
    Rubio, J. M.
    Sanchez-Borque, P.
    Farre, J.
    EUROPEAN HEART JOURNAL, 2014, 35 : 331 - 331
  • [48] The clinical benefit of cardiac resynchronization therapy for narrow QRS compared to broad QRS complex patients
    Yap, Lok B.
    Qadir, Faisal
    Nguyen, Son T. B.
    Ma, Soot K.
    Koh, Kokw.
    Muhammad, Zulkeflee
    Arshad, Akmal H.
    Ali, Zunida
    Daud, Azlina
    Tay, Giat S.
    Sahat, Noor A.
    Said, Amirzua A.
    Tamin, Syahidah S.
    Hussin, Azlan
    Kaur, Surinder
    Omar, Razali
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 183 : 178 - 179
  • [49] QRS-complex shortening as predictor for electromechanical restoration in heart failure patients with cardiac resynchronization therapy (Cardiac Resynchronization Therapy)
    Butter, C
    Schlegl, M
    Schurr, M
    Wellnhofer, E
    Fleck, E
    EUROPEAN HEART JOURNAL, 2002, 23 : 275 - 275
  • [50] Cardiac resynchronization therapy optimization by ultrasonic cardiac output monitoring (USCOM) device
    Siu, Chung-Wah
    Tse, Hung-Fat
    Lee, Kathy
    Chan, Hon-Wah
    Chen, Wai-Hong
    Yung, Cindy
    Lee, Stephen
    Lau, Chu-Pak
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (01): : 50 - 55