Inadvertent QRS prolongation by an optimization device-based algorithm in patients with cardiac resynchronization therapy

被引:0
|
作者
Sedlacek, Kamil [1 ,2 ]
Polasek, Rostislav [3 ]
Jansova, Helena [4 ]
Grieco, Domenico [5 ]
Kucera, Pavel [3 ]
Kautzner, Josef [4 ]
Francis, Darrel P. [6 ]
Wichterle, Dan [4 ,7 ]
机构
[1] Univ Hosp, Dept Internal Med Cardiol & Angiol 1, Hradec Kralove, Czech Republic
[2] Charles Univ Prague, Fac Med, Hradec Kralove, Czech Republic
[3] Liberec Reg Hosp, Cardiol Dept, Liberec, Czech Republic
[4] Inst Clin & Expt Med, Dept Cardiol, Prague, Czech Republic
[5] Policlin Casilino Rome, Dept Cardiovasc Sci, Rome, Italy
[6] Imperial Coll London, Hammersmith Hosp, Int Ctr Circulatory Hlth, Natl Heart & Lung Inst, London, England
[7] Charles Univ Prague, Fac Med 1, Dept Internal Cardiovasc Med 2, Prague, Czech Republic
来源
PLOS ONE | 2022年 / 17卷 / 09期
关键词
HEART-FAILURE; DELAY OPTIMIZATION; ATRIOVENTRICULAR DELAY; INTERVAL; MORTALITY;
D O I
10.1371/journal.pone.0275276
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Device-based algorithms offer the potential for automated optimization of cardiac resynchronization therapy (CRT), but the process for accepting them into clinical use is currently still ad-hoc, rather than based on pre-clinical and clinical testing of specific features of validity. We investigated how the QuickOpt-guided VV delay (VVD) programming performs against the clinical and engineering heuristic of QRS complex shortening by CRT. Methods A prospective, 2-center study enrolled 37 consecutive patients with CRT. QRS complex duration (QRSd) was assessed during intrinsic atrioventricular conduction, synchronous biventricular pacing, and biventricular pacing with QuickOpt-proposed VVD. The measurements were done manually by electronic calipers in signal-averaged and magnified 12-lead QRS complexes. Results Native QRSd was 174 +/- 22 ms. Biventricular pacing with empiric AVD and synchronous VVD resulted in QRSd 156 +/- 20 ms, a significant narrowing from the baseline QRSd by 17 +/- 27 ms, P = 0.0003. In 36 of 37 patients, the QuickOpt algorithm recommended left ventricular preexcitation with VVD of 42 +/- 18 ms (median 40 ms; interquartile range 30-55 ms, P < 0.00001). QRSd in biventricular pacing with QuickOpt-based VVD was significantly longer compared with synchronous biventricular pacing (168 +/- 25 ms vs. 156 +/- 20 ms; difference 12 +/- 11ms; P < 0.00001). This prolongation correlated with the absolute VVD value (R = 0.66, P < 0.00001). Conclusions QuickOpt algorithm systematically favours a left-preexcitation VVD which translates into a significant prolongation of the QRSd compared to synchronous biventricular pacing. There is no reason to believe that a manipulation that systematically widens QRSd should be considered to optimize physiology. Device-based CRT optimization algorithms should undergo systematic mechanistic pre-clinical evaluation in various scenarios before they are tested in large clinical studies.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Optimization of the Interventricular Delay in Cardiac Resynchronization Therapy Using the QRS Width
    Tamborero, David
    Mont, Lluis
    Sitges, Marta
    Silva, Etelvino
    Berruezo, Antonio
    Vidal, Barbara
    Delgado, Victoria
    Tolosana, Jose M.
    Godoy, Miguel
    Castel, Angeles
    Brugada, Josep
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (10): : 1407 - 1412
  • [32] QRS Duration Criteria to Select Patients for Cardiac Resynchronization Therapy Cardiac Resynchronization Therapy: 150 Is Not A Magic Number!
    Guglin, Maya
    Curtis, Anne B.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (02): : 429 - 435
  • [33] Efficacy of Cardiac Resynchronization Therapy in Patients with a Narrow QRS Complex
    Nakai, Toshiko
    Ikeya, Yukitoshi
    Mano, Hiroaki
    Kogawa, Rikitake
    Watanabe, Ryuta
    Arai, Masaru
    Aizawa, Yoshihiro
    Kurokawa, Sayaka
    Ohkubo, Kimie
    Kitano, Daisuke
    Nagashima, Koichi
    Okumura, Yasuo
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2021, 2021
  • [34] Cardiac resynchronization therapy in patients with narrow QRS: what benefits?
    Vincenti, Antonio
    GIORNALE ITALIANO DI CARDIOLOGIA, 2012, 13 (10) : 157S - 159S
  • [35] Impact of long-term optimizing atrioventricular delay using device-based algorithms on cardiac resynchronization therapy
    Yoshifumi Ikeda
    Ritsushi Kato
    Kenta Tsutsui
    Hitoshi Mori
    Daisuke Kawano
    Sayaka Tanaka
    Shintaro Nakano
    Takaaki Senbonmatsu
    Shiro Iwanaga
    Toshihiro Muramatsu
    Kazuo Matsumoto
    Heart and Vessels, 2023, 38 (2) : 216 - 227
  • [36] Impact of long-term optimizing atrioventricular delay using device-based algorithms on cardiac resynchronization therapy
    Ikeda, Yoshifumi
    Kato, Ritsushi
    Tsutsui, Kenta
    Mori, Hitoshi
    Kawano, Daisuke
    Tanaka, Sayaka
    Nakano, Shintaro
    Senbonmatsu, Takaaki
    Iwanaga, Shiro
    Muramatsu, Toshihiro
    Matsumoto, Kazuo
    HEART AND VESSELS, 2023, 38 (02) : 216 - 227
  • [37] Changes of QRS Duration After Optimization of VV Intervals by Cardiac Resynchronization Therapy
    Li, Danfang
    Wang, Dongmei
    Zang, Hongyun
    Yu, Haibo
    Han, Yaling
    CIRCULATION, 2010, 122 (02) : E233 - E233
  • [38] The effects of QRS duration and atrial pacing on atrioventricular optimization of cardiac resynchronization therapy
    Gold, Michael R.
    Niazi, Imran
    Giudici, Michael
    Yu, Yinghong
    Arcot-Krishnamurthy, Shantha
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 2A - 2A
  • [39] Changes of QRS Duration after Optimization of VV Intervals by Cardiac Resynchronization Therapy
    Li, D. F.
    Wang, D. M.
    Zang, H. Y.
    Yu, H. B.
    Han, Y. L.
    CARDIOLOGY, 2009, 114 : 27 - 27
  • [40] CHARACTERIZATION OF RESPONSE TO CARDIAC RESYNCHRONIZATION THERAPY IN PATIENTS WITH A NARROW QRS COMPLEX
    Rickard, Jack
    Cronin, Edmond
    Spragg, David
    Cheng, Alan
    Tang, Wai Hong
    Grimm, Richard
    Wilkoff, Bruce
    Varma, Niraj
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E357 - E357