Predicting pulmonary hypoplasia using the sonographic fetal lung volume to body weight ratio - how precise and accurate is it?

被引:24
|
作者
Ruano, R. [1 ]
Martinovic, J. [1 ]
Aubry, M. -C. [1 ]
Dumez, Y. [1 ]
Benachi, A. [1 ]
机构
[1] Univ Paris 05, Hop Necker Enfants Malades, AP HP, Serv Foetopathol, F-75743 Paris 15, France
关键词
congenital diaphragmatic hernia; fetal lung; prenatal diagnosis; pulmonary hypoplasia; three-dimensional ultrasound; ultrasound;
D O I
10.1002/uog.3853
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To determine the precision and accuracy of ultrasound in estimating the fetal lung to body weight ratio (ELB ratio) using two-dimensional (2D) and three-dimensional (3D) ultrasound by comparison with postmortem measurements, and to evaluate its potential to diagnose pulmonary hypoplasia. Methods Lung volumes were estimated by 3D ultrasound (rotational technique) and fetal weights were measured by 2D ultrasound (Hadlock equation) in 35 fetuses immediately before termination of Pregnancy at 15-38 weeks. Sonograpbic estimates of FLB ratio were compared with postmortem values. Based on the pathological definition of Pulmonary hypoplasia, the accuracy of sonographic estimation of the FLB ratio was analyzed. Results The mean gestational age at termination of pregnancy was 26.7 (range, 15-38) weeks. The mean ELB ratios were 0.018 (SD, 0.006) on ultrasound and 0.019 (SD, 0.007) at autopsy (P = 0.730). Bias and precision of sonograpbic FLB ratio were -0.001 and 0.003 (absolute limits, -0.007 to +0.006), respectively. Pulmonary hypoplasia was diagnosed in 12 (34.3%) cases at autopsy. The sonographic FLB ratio was significantly lower in fetuses with pulmonary hypoplasia at autopsy (median, 0.011; range, 0.004-0.014) than it was in those without pulmonary hypoplasia (median, 0.022; range, 0.013-0.045, P < 0.001). The sensitivity and specificity of the sonographic FLB ratio for diagnosing pulmonary hypoplasia were 91.7% (11/12) and 91.3% (21/23), respectively, the positive and negative predictive values were 84.6% (11/13) and 95.5% (21/22), and the accuracy was 91.4% (32/35). Conclusion FLB ratio can be estimated precisely on ultrasound examination, albeit with wide limits of agreement. The sonographically estimated FLB ratio may be useful in the prediction and diagnosis of pulmonary bypoplasia. Copyright (c) 2006 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:958 / 962
页数:5
相关论文
共 44 条
  • [41] Accurate quantification of pulmonary perfusion ratio in children with congenital heart disease using partial volume corrected 4D flow cardiac magnetic resonance
    Lagerstrand, Kerstin
    Nystrom, Anna
    Svensson, Par-Arne
    De Lange, Charlotte
    Dangardt, Frida
    FRONTIERS IN PEDIATRICS, 2024, 12
  • [42] Predicting life-threatening hemoptysis in traumatic pulmonary parenchymal injury using computed tomography semi-automated lung volume quantification
    Tang, Wen-Ruei
    Chang, Chao-Chun
    Wu, Chen-Yu
    Wang, Chih-Jung
    Yang, Tsung-Han
    Hung, Kuo-Shu
    Liu, Yi-Sheng
    Lin, Chia-Ying
    Yen, Yi-Ting
    INSIGHTS INTO IMAGING, 2024, 15 (01):
  • [43] Prenatal prediction of respiratory distress syndrome by multimodality approach using 3D lung ultrasound, lung-to-liver intensity ratio tissue histogram and pulmonary artery Doppler assessment of fetal lung maturity
    Khalifa, Yasmin Essameldin Abdalla
    Aboulghar, Mona M.
    Hamed, Soha T.
    Tomerak, Rania H.
    Asfour, Ahmed M.
    Kamal, Eman F.
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1128):
  • [44] Lecithin can be detected by volume-selected proton MR spectroscopy using a 1•5T whole body scanner:: A potentially non-invasive method for the prenatal assessment of fetal lung maturity
    Fenton, BW
    Lin, CS
    Seydel, F
    Macedonia, C
    PRENATAL DIAGNOSIS, 1998, 18 (12) : 1263 - 1266