Predicting pulmonary hypoplasia using the sonographic fetal lung volume to body weight ratio - how precise and accurate is it?

被引:24
|
作者
Ruano, R. [1 ]
Martinovic, J. [1 ]
Aubry, M. -C. [1 ]
Dumez, Y. [1 ]
Benachi, A. [1 ]
机构
[1] Univ Paris 05, Hop Necker Enfants Malades, AP HP, Serv Foetopathol, F-75743 Paris 15, France
关键词
congenital diaphragmatic hernia; fetal lung; prenatal diagnosis; pulmonary hypoplasia; three-dimensional ultrasound; ultrasound;
D O I
10.1002/uog.3853
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To determine the precision and accuracy of ultrasound in estimating the fetal lung to body weight ratio (ELB ratio) using two-dimensional (2D) and three-dimensional (3D) ultrasound by comparison with postmortem measurements, and to evaluate its potential to diagnose pulmonary hypoplasia. Methods Lung volumes were estimated by 3D ultrasound (rotational technique) and fetal weights were measured by 2D ultrasound (Hadlock equation) in 35 fetuses immediately before termination of Pregnancy at 15-38 weeks. Sonograpbic estimates of FLB ratio were compared with postmortem values. Based on the pathological definition of Pulmonary hypoplasia, the accuracy of sonographic estimation of the FLB ratio was analyzed. Results The mean gestational age at termination of pregnancy was 26.7 (range, 15-38) weeks. The mean ELB ratios were 0.018 (SD, 0.006) on ultrasound and 0.019 (SD, 0.007) at autopsy (P = 0.730). Bias and precision of sonograpbic FLB ratio were -0.001 and 0.003 (absolute limits, -0.007 to +0.006), respectively. Pulmonary hypoplasia was diagnosed in 12 (34.3%) cases at autopsy. The sonographic FLB ratio was significantly lower in fetuses with pulmonary hypoplasia at autopsy (median, 0.011; range, 0.004-0.014) than it was in those without pulmonary hypoplasia (median, 0.022; range, 0.013-0.045, P < 0.001). The sensitivity and specificity of the sonographic FLB ratio for diagnosing pulmonary hypoplasia were 91.7% (11/12) and 91.3% (21/23), respectively, the positive and negative predictive values were 84.6% (11/13) and 95.5% (21/22), and the accuracy was 91.4% (32/35). Conclusion FLB ratio can be estimated precisely on ultrasound examination, albeit with wide limits of agreement. The sonographically estimated FLB ratio may be useful in the prediction and diagnosis of pulmonary bypoplasia. Copyright (c) 2006 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:958 / 962
页数:5
相关论文
共 44 条
  • [31] Liver Function Following Extended Hepatectomy Can Be Accurately Predicted Using Remnant Liver Volume to Body Weight Ratio
    Stéphanie Truant
    Emmanuel Boleslawski
    Géraldine Sergent
    Emmanuelle Leteurtre
    Alain Duhamel
    Mohamed Hebbar
    François-René Pruvot
    World Journal of Surgery, 2015, 39 : 1193 - 1201
  • [32] Liver Function Following Extended Hepatectomy Can Be Accurately Predicted Using Remnant Liver Volume to Body Weight Ratio
    Truant, Stephanie
    Boleslawski, Emmanuel
    Sergent, Geraldine
    Leteurtre, Emmanuelle
    Duhamel, Alain
    Hebbar, Mohamed
    Pruvot, Francois-Rene
    WORLD JOURNAL OF SURGERY, 2015, 39 (05) : 1193 - 1201
  • [33] A non-invasive method to predict fetal lung maturity using fetal pulmonary artery Doppler wave acceleration time/ejection time ratio
    Schenone, Mauro
    Samson, Jacques
    Suhag, Anju
    Jenkins, Laura
    Mari, Giancarlo
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2012, 206 (01) : S170 - S170
  • [34] A Non-Invasive Method To Predict Lung Maturity Using the Impedance Ratio of the Fetal Pulmonary Artery and Ductus Arteriosus.
    Schenone, Mauro H.
    Samson, Jacques E.
    Suhag, Anju
    Jenkins, Laura
    Mari, Giancarlo
    REPRODUCTIVE SCIENCES, 2012, 19 (S3) : 249A - 250A
  • [35] Diagnostic value of congenital pulmonary airway malformation volume ratio for fetal hydrops due to congenital lung malformations: a systematic review and meta-analysis
    Pei Zhu
    Kaisheng Cheng
    Mingsheng He
    Yutong Wang
    Pengyue Shen
    Kanglin He
    Chang Xu
    Ben Zhang
    Zhenmi Liu
    Orphanet Journal of Rare Diseases, 17
  • [36] Diagnostic value of congenital pulmonary airway malformation volume ratio for fetal hydrops due to congenital lung malformations: a systematic review and meta-analysis
    Zhu, Pei
    Cheng, Kaisheng
    He, Mingsheng
    Wang, Yutong
    Shen, Pengyue
    He, Kanglin
    Xu, Chang
    Zhang, Ben
    Liu, Zhenmi
    ORPHANET JOURNAL OF RARE DISEASES, 2022, 17 (01)
  • [37] The utility of sequential testing using the ratio of surfactant to albumin and lamellar body counts in amniotic fluid for assessing fetal lung maturity
    Vicdan, K
    Var, T
    Danisman, N
    Gokmen, O
    JOURNAL OF MATERNAL-FETAL INVESTIGATION, 1996, 6 (03): : 136 - 141
  • [38] Combined measurement of fetal lung volume and pulmonary artery resistance index is more accurate for prediction of neonatal respiratory distress syndrome in preterm fetuses: a pilot study
    Laban, Mohamed
    Mansour, Ghada M.
    El-Kotb, Ahmed
    Hassanin, Alaa
    Laban, Zina
    Saleh, Abdelrahman
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2019, 32 (04): : 626 - 632
  • [39] Prenatal prediction of survival in isolated diaphragmatic hernia using observed to expected total fetal lung volume determined by magnetic resonance imaging based on either gestational age or fetal body volume
    Cannie, M.
    Jani, J.
    Meersschaert, J.
    Allegaert, K.
    Done, E.
    Marchal, G.
    Deprest, J.
    Dymarkowski, S.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 32 (05) : 633 - 639
  • [40] Novel method for estimating the total blood volume: the importance of adjustment using the ideal body weight and age for the accurate prediction of haemodilution during cardiopulmonary bypass
    Muraki, Ryosuke
    Hiraoka, Arudo
    Nagata, Kazuyuki
    Nakajima, Kosuke
    Oshita, Tomoya
    Arimichi, Masahisa
    Chikazawa, Genta
    Yoshitaka, Hidenori
    Sakaguchi, Taichi
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2018, 27 (06) : 802 - 807