Predicting pulmonary hypoplasia using the sonographic fetal lung volume to body weight ratio - how precise and accurate is it?

被引:24
|
作者
Ruano, R. [1 ]
Martinovic, J. [1 ]
Aubry, M. -C. [1 ]
Dumez, Y. [1 ]
Benachi, A. [1 ]
机构
[1] Univ Paris 05, Hop Necker Enfants Malades, AP HP, Serv Foetopathol, F-75743 Paris 15, France
关键词
congenital diaphragmatic hernia; fetal lung; prenatal diagnosis; pulmonary hypoplasia; three-dimensional ultrasound; ultrasound;
D O I
10.1002/uog.3853
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives To determine the precision and accuracy of ultrasound in estimating the fetal lung to body weight ratio (ELB ratio) using two-dimensional (2D) and three-dimensional (3D) ultrasound by comparison with postmortem measurements, and to evaluate its potential to diagnose pulmonary hypoplasia. Methods Lung volumes were estimated by 3D ultrasound (rotational technique) and fetal weights were measured by 2D ultrasound (Hadlock equation) in 35 fetuses immediately before termination of Pregnancy at 15-38 weeks. Sonograpbic estimates of FLB ratio were compared with postmortem values. Based on the pathological definition of Pulmonary hypoplasia, the accuracy of sonographic estimation of the FLB ratio was analyzed. Results The mean gestational age at termination of pregnancy was 26.7 (range, 15-38) weeks. The mean ELB ratios were 0.018 (SD, 0.006) on ultrasound and 0.019 (SD, 0.007) at autopsy (P = 0.730). Bias and precision of sonograpbic FLB ratio were -0.001 and 0.003 (absolute limits, -0.007 to +0.006), respectively. Pulmonary hypoplasia was diagnosed in 12 (34.3%) cases at autopsy. The sonographic FLB ratio was significantly lower in fetuses with pulmonary hypoplasia at autopsy (median, 0.011; range, 0.004-0.014) than it was in those without pulmonary hypoplasia (median, 0.022; range, 0.013-0.045, P < 0.001). The sensitivity and specificity of the sonographic FLB ratio for diagnosing pulmonary hypoplasia were 91.7% (11/12) and 91.3% (21/23), respectively, the positive and negative predictive values were 84.6% (11/13) and 95.5% (21/22), and the accuracy was 91.4% (32/35). Conclusion FLB ratio can be estimated precisely on ultrasound examination, albeit with wide limits of agreement. The sonographically estimated FLB ratio may be useful in the prediction and diagnosis of pulmonary bypoplasia. Copyright (c) 2006 ISUOG. Published by John Wiley & Sons, Ltd.
引用
收藏
页码:958 / 962
页数:5
相关论文
共 44 条
  • [1] Predicting neonatal deaths and pulmonary hypoplasia in isolated congenital diaphragmatic hernia using the sonographic fetal lung volume-body weight ratio
    Ruano, Rodrigo
    Aubry, Marie-Cecile
    Dumez, Yves
    Zugaib, Marcelo
    Benachi, Alexandra
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (05) : 1216 - 1219
  • [2] Pulmonary hypoplasia: Prediction with use of ratio of MR imaging-measured fetal lung volume to US-estimated fetal body weight
    Tanigaki, S
    Miyakoshi, K
    Tanaka, M
    Hattori, Y
    Matsumoto, T
    Ueno, K
    Uehara, K
    Nishimura, O
    Minegishi, K
    Ishimoto, H
    Shinmoto, H
    Ikeda, K
    Yoshimura, Y
    RADIOLOGY, 2004, 232 (03) : 767 - 772
  • [3] Prenatal sonographic chest and lung measurements for predicting severe pulmonary hypoplasia
    Merz, E
    Miric-Tesanic, D
    Bahlmann, F
    Weber, G
    Hallermann, C
    PRENATAL DIAGNOSIS, 1999, 19 (07) : 614 - 619
  • [4] Predicting pulmonary hypoplasia: assessment of lung volume or lung function or both?
    Wladimiroff, JW
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1998, 11 (03) : 164 - 166
  • [5] Fetal body volume: Use at MR imaging to quantify relative lung volume in fetuses suspected of having pulmonary hypoplasia
    Cannie, Mieke
    Jani, Jacques C.
    De Keyzer, Frederik
    Devlieger, Roland
    Van Schoubroeck, Dominique
    Witters, Ingrid
    Marchal, Guy
    Dymarkowski, Steven
    Deprest, Jan A.
    RADIOLOGY, 2006, 241 (03) : 847 - 853
  • [6] Predicting severe pulmonary hypoplasia in lower urinary tract obstruction using fetal lung area
    Ruano, Rodrigo
    Dunn, Timothy N.
    Blumenfeld, Yair J.
    de la Penha, Maria Carmen L. M.
    Koh, Chester J.
    Angelo, Joseph
    Grimm, Paul
    Hintz, Susan R.
    Roth, David R.
    Welty, Stephen
    Braun, Michael C.
    Belfort, Michael A.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (01) : S102 - S102
  • [7] Predicting Fetal Lung Maturity Using the Fetal Pulmonary Artery Doppler Wave Acceleration/Ejection Time Ratio
    Schenone, Mauro H.
    Samson, Jacques E.
    Jenkins, Laura
    Suhag, Anju
    Mari, Giancarlo
    FETAL DIAGNOSIS AND THERAPY, 2014, 36 (03) : 208 - 214
  • [8] The accuracy of sonographic fetal weight estimation in cases of breech presentation-how accurate we are?
    Melamed, Nir
    Yogev, Yariv
    Mashiach, Reuven
    Meizner, Israel
    Pardo, Joseph
    Ben-Haroush, Avi
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2011, 204 : S277 - S277
  • [9] Prenatal sonographic chest and lung measurements for predicting severe pulmonary hypoplasia in left-sided congenital diaphragmatic hernia
    Nakata, M
    Sase, M
    Anno, K
    Sumie, M
    Hasegawa, K
    Nakamura, Y
    Kato, H
    EARLY HUMAN DEVELOPMENT, 2003, 72 (01) : 75 - 81
  • [10] Fetal lung-to-liver signal intensity ratio at MR imaging: Development of a normal scale and possible gy role in predicting pulmonary hypoplasia in utero
    Brewerton, L
    Chari, RS
    Liang, YY
    Bhargava, R
    RADIOLOGY, 2005, 235 (03) : 1005 - 1010