Dry powder inhalers: Particle size and patient-satisfaction

被引:2
|
作者
Jindal, S. K. [1 ]
Pandey, K. K. [2 ,3 ]
Bose, P. P. [4 ,5 ]
机构
[1] Post Grad Inst Med Educ & Res, Dept Pulm Med, Jindal Clin, Chandigarh, India
[2] Yashoda Super Special Hosp, Dept Pulmonol, Ghaziabad, Uttar Pradesh, India
[3] Galaxy Hosp & Inst Pulmonol, Dept Pulmonol, Delhi, India
[4] President Saans Fdn, Delhi, India
[5] Natl Heart Inst, Delhi, India
关键词
Asthma; chronic obstructive pulmonary disease; dry powder inhaler; inhalational devices; mouthfeel; particle size; patient education;
D O I
10.4103/ijrc.ijrc_57_19
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Inhalational route is the cornerstone for drug delivery in asthma. Dry powder inhalers efficiently deliver drug particles to lungs depending on patients' breath actuation and without using propellants. Drug delivery in lungs is dependent primarily on particle size distribution of the formulation. Several studies have proved that drug particles 1-3 mu m in size provide optimum efficacy with minimum adverse events. Particles >3 mu m are deposited in the oropharynx and those <1 mu m are exhaled. However, these fine particles might not be felt in the mouth due to which patients may feel that appropriate amount of drug was not dispensed. This perception may negatively influence patient satisfaction and confidence on the device. The patient education on the absence of mouthfeel is thus essential. Treating physicians should provide optimum patient counseling and education addressing the importance of particle size for desired clinical effects.
引用
收藏
页码:14 / 18
页数:5
相关论文
共 50 条
  • [41] Protein deposition from dry powder inhalers: Fine particle multiplets as performance modifiers
    Lucas, P
    Anderson, K
    Staniforth, JN
    PHARMACEUTICAL RESEARCH, 1998, 15 (04) : 562 - 569
  • [42] Protein Deposition from Dry Powder Inhalers: Fine Particle Multiplets as Performance Modifiers
    Paul Lucas
    Kerry Anderson
    John N. Staniforth
    Pharmaceutical Research, 1998, 15 : 562 - 569
  • [43] Dry Powder Inhalers for Delivery of Synthetic Biomolecules
    Omidian, Hossein
    Nokhodchi, Ali
    Babanejad, Niloofar
    PHARMACEUTICALS, 2025, 18 (02)
  • [44] Determining patient-satisfaction as part of quality management in hospital
    Klotz, T
    Zumbe, J
    Velmans, R
    Engelmann, U
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1996, 121 (28-29) : 889 - 895
  • [45] The effect of medical education on students' patient-satisfaction ratings
    Klamen, DL
    Williams, RG
    ACADEMIC MEDICINE, 1997, 72 (01) : 57 - 61
  • [46] Dry Powder Inhalers: From Bench to Bedside
    Chrystyn, Henry
    Azouz, Wahida
    Tarsin, Walid
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2023, 36 (06) : 324 - 335
  • [47] Towards the optimisation and adaptation of dry powder inhalers
    Cui, Y.
    Schmalfuss, S.
    Zellnitz, S.
    Sommerfeld, M.
    Urbanetz, N.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2014, 470 (1-2) : 120 - 132
  • [48] Dry-powder inhalers in acute asthma
    Selroos, Olof
    THERAPEUTIC DELIVERY, 2014, 5 (01) : 69 - 81
  • [49] Influence of carrier on the performance of dry powder inhalers
    Saint-Lorant, G.
    Leterme, P.
    Gayot, A.
    Flament, M. P.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2007, 334 (1-2) : 85 - 91
  • [50] Are outcomes the same with all dry powder inhalers?
    Thomas, M