Dry powder inhalers: Particle size and patient-satisfaction

被引:2
|
作者
Jindal, S. K. [1 ]
Pandey, K. K. [2 ,3 ]
Bose, P. P. [4 ,5 ]
机构
[1] Post Grad Inst Med Educ & Res, Dept Pulm Med, Jindal Clin, Chandigarh, India
[2] Yashoda Super Special Hosp, Dept Pulmonol, Ghaziabad, Uttar Pradesh, India
[3] Galaxy Hosp & Inst Pulmonol, Dept Pulmonol, Delhi, India
[4] President Saans Fdn, Delhi, India
[5] Natl Heart Inst, Delhi, India
关键词
Asthma; chronic obstructive pulmonary disease; dry powder inhaler; inhalational devices; mouthfeel; particle size; patient education;
D O I
10.4103/ijrc.ijrc_57_19
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Inhalational route is the cornerstone for drug delivery in asthma. Dry powder inhalers efficiently deliver drug particles to lungs depending on patients' breath actuation and without using propellants. Drug delivery in lungs is dependent primarily on particle size distribution of the formulation. Several studies have proved that drug particles 1-3 mu m in size provide optimum efficacy with minimum adverse events. Particles >3 mu m are deposited in the oropharynx and those <1 mu m are exhaled. However, these fine particles might not be felt in the mouth due to which patients may feel that appropriate amount of drug was not dispensed. This perception may negatively influence patient satisfaction and confidence on the device. The patient education on the absence of mouthfeel is thus essential. Treating physicians should provide optimum patient counseling and education addressing the importance of particle size for desired clinical effects.
引用
收藏
页码:14 / 18
页数:5
相关论文
共 50 条
  • [21] Dimensions of patient-satisfaction, patient evaluation of orthodontic care
    Milani, MS
    Meerschaert, V
    Prahl-Andersen, B
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 380 - 380
  • [22] Understanding Dry Powder Inhalers: Key Technical and Patient Preference Attributes
    Mark L. Levy
    Will Carroll
    José L. Izquierdo Alonso
    Claus Keller
    Federico Lavorini
    Lauri Lehtimäki
    Advances in Therapy, 2019, 36 : 2547 - 2557
  • [23] Understanding Dry Powder Inhalers: Key Technical and Patient Preference Attributes
    Levy, Mark L.
    Carroll, Will
    Izquierdo Alonso, Jose L.
    Keller, Claus
    Lavorini, Federico
    Lehtimaki, Lauri
    ADVANCES IN THERAPY, 2019, 36 (10) : 2547 - 2557
  • [24] Single particle friction on blister packaging materials used in dry powder inhalers
    Bunker, Matthew J.
    Davies, Martyn C.
    Chen, Xinyong
    James, Michael B.
    Roberts, Clive J.
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 29 (05) : 405 - 413
  • [25] Use of dry powder inhalers in COPD
    Wilson, D. S.
    Gillion, M. S.
    Rees, P. J.
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2007, 61 (12) : 2005 - 2008
  • [26] Formulation considerations for dry powder inhalers
    Cordts, Eike
    Steckel, Hartwig
    THERAPEUTIC DELIVERY, 2014, 5 (06) : 675 - 689
  • [27] Dry powder inhalers of antitubercular drugs
    Nainwal, Nidhi
    Sharma, Yuwanshi
    Jakhmola, Vikash
    TUBERCULOSIS, 2022, 135
  • [28] Dry powder inhalers and the risk of error
    Terzano, Claudio
    RESPIRATION, 2008, 75 (01) : 14 - 15
  • [29] EFFECTIVENESS AND ACCEPTANCE OF DRY POWDER INHALERS
    KOHLER, D
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1995, 120 (41) : 1401 - 1404
  • [30] Formation of particles for dry powder inhalers
    Gradon, Leon
    Sosnowski, Tomasz R.
    ADVANCED POWDER TECHNOLOGY, 2014, 25 (01) : 43 - 55