Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics

被引:23
|
作者
Chea, Michel [1 ]
Fezzani, Karen [1 ]
Jacob, Julian [1 ]
Cuttat, Marguerite [2 ]
Croise, Mathilde [1 ]
Simon, Jean-Marc [1 ]
Feuvret, Loic [1 ]
Valery, Charles-Ambroise [2 ]
Maingon, Philippe [1 ]
Benadjaoud, Mohamed-Amine [3 ]
Jenny, Catherine [1 ]
机构
[1] Sorbonne Univ, Dept Radiat Oncol, Pitie Salpetriere Hosp, AP HP, 47-83 Blvd Hop, F-75651 Paris 13, France
[2] Sorbonne Univ, Neurosurg Dept, Pitie Salpetriere Hosp, AP HP, Paris, France
[3] PSE SANTE SERAMED, Radiat Protect & Nucl Safety Inst, Fontenay Aux Roses, France
关键词
Stereotactic radiosurgery; Multiple brain metastases; Single-isocenter; Gammaknife; Gradient index; Dose fall-off; Target volume effect; STEREOTACTIC RADIOSURGERY; VMAT; INDEX; PLANS;
D O I
10.1186/s13014-021-01766-w
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To compare linac-based mono-isocentric radiosurgery with Brainlab Elements Multiple Brain Mets (MBM) SRS and the Gamma Knife using a specific statistical method and to analyze the dosimetric impact of the target volume geometric characteristics. A dose fall-off analysis allowed to evaluate the Gradient Index relevancy for the dose spillage characterization. Material and methods Treatments were planned on twenty patients with three to nine brain metastases with MBM 2.0 and GammaPlan 11.0. Ninety-five metastases ranging from 0.02 to 9.61 cc were included. Paddick Index (PI), Gradient Index (GI), dose fall-off, volume of healthy brain receiving more than 12 Gy (V-12Gy) and DVH were used for the plan comparison according to target volume, major axis diameter and Sphericity Index (SI). The multivariate regression approach allowed to analyze the impact of each geometric characteristic keeping all the others unchanged. A parallel study was led to evaluate the impact of the isodose line (IDL) prescription on the MBM plan quality. Results For mono-isocentric linac-based radiosurgery, the IDL around 70-75% was the best compromise found. For both techniques, the GI and the dose fall-off decreased with the target volume. In comparison, PI was slightly improved with MBM for targets < 1 cc or SI > 0.78. GI was improved with GP for targets < 2.5 cc. The V-12Gy was higher with MBM for lesions > 0.4 cc or SI < 0.84 and exceeded 10 cc for targets > 5 cc against 6.5 cc with GP. The presence of OAR close to the PTV had no impact on the dose fall off values. The dose fall-off was higher for volumes < 3.8 cc with GP which had the sharpest dose fall-off in the infero-superior direction up to 30%/mm. The mean beam-on time was 94 min with GP against 13 min with MBM. Conclusions The dose fall-off and the V-12Gy were more relevant indicators than the GI for the low dose spillage assessment. Both evaluated techniques have comparable plan qualities with a slightly improved selectivity with MBM for smaller lesions but with a healthy tissues sparing slightly favorable to GP at the expense of a considerably longer irradiation time. However, a higher healthy tissue exposure must be considered for large volumes in MBM plans.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Dosimetric Impact of Patient Rotational Setup Errors with Frameless Single-Isocenter, Multi-Target Volumetric Modulated Arc Radiosurgery for Multiple Brain Metastases
    Clark, G. M.
    Fiveash, J. B.
    Prendergast, B. M.
    Willey, C. W.
    Spencer, S. A.
    Thomas, E. M.
    Guthrie, B. L.
    Popple, R. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S888 - S888
  • [22] FEASIBILITY OF SINGLE-ISOCENTER VOLUMETRIC MODULATED ARC RADIOSURGERY FOR TREATMENT OF MULTIPLE BRAIN METASTASES
    Clark, Grant M.
    Popple, Richard A.
    Young, P. Edward
    Fiveash, John B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (01): : 296 - 302
  • [23] Single isocenter dynamic conformal arcs-based radiosurgery for brain metastases: Dosimetric comparison with Cyberknife and clinical investigation
    Oshiro, Yoshiko
    Mizumoto, Masashi
    Kato, Yuichi
    Tsuchida, Yukihiro
    Tsuboi, Koji
    Sakae, Takeji
    Sakurai, Hideyuki
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2024, 29
  • [24] Restricted single isocenter for multiple targets dynamic conformal arc (RSIMT DCA) technique for brain stereotactic radiosurgery (SRS) planning
    Chang, Jenghwa
    Wernicke, A. Gabriella
    Pannullo, Susan C.
    JOURNAL OF RADIOSURGERY AND SBRT, 2018, 5 (02): : 145 - 156
  • [25] Plan comparison of volumetric modulated arc therapy with gamma knife radiosurgery for multiple brain metastases
    Nomoto, A. K.
    Sakumi, A.
    Takahashi, W.
    Igaki, H.
    Iwai, Y.
    Yoda, K.
    Nakagawa, K.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S220 - S221
  • [26] Dosimetric Comparison Between Single Isocenter Brain Metastases Treatment Using Dynamic Conformal Arcs (Elements) and VMAT (RapidARC)
    Venencia, C.
    Morais Cardozo, R.
    Almada, M.
    Rivelli, G.
    Garrigo, E.
    Castro Pena, P.
    MEDICAL PHYSICS, 2017, 44 (06) : 2970 - 2971
  • [27] A Novel Algorithm for Rapid Generation of Single Isocenter Dynamic Conformal Arc Plans for Simultaneous Treatment of Multiple Brain Metastases
    Maurer, J.
    Wiant, D. B.
    Liu, H.
    Manning, M.
    Sintay, B. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E695 - E695
  • [28] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Raza, Giorgio Hamid
    Capone, Luca
    Tini, Paolo
    Giraffa, Martina
    Gentile, Piercarlo
    Minniti, Giuseppe
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [29] Single-isocenter multiple-target stereotactic radiosurgery for multiple brain metastases: dosimetric evaluation of two automated treatment planning systems
    Giorgio Hamid Raza
    Luca Capone
    Paolo Tini
    Martina Giraffa
    Piercarlo Gentile
    Giuseppe Minniti
    Radiation Oncology, 17
  • [30] Effects of Multileaf Collimator Design an Function When Using an Optimized Dynamic Conformal Arc Approach for Stereotactic Radiosurgery Treatment of Multiple Brain Metastases With a Single Isocenter: A Planning Study
    Taylor, Michael
    Williams, Jamone
    Gleason, John F.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (08)