Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics

被引:23
|
作者
Chea, Michel [1 ]
Fezzani, Karen [1 ]
Jacob, Julian [1 ]
Cuttat, Marguerite [2 ]
Croise, Mathilde [1 ]
Simon, Jean-Marc [1 ]
Feuvret, Loic [1 ]
Valery, Charles-Ambroise [2 ]
Maingon, Philippe [1 ]
Benadjaoud, Mohamed-Amine [3 ]
Jenny, Catherine [1 ]
机构
[1] Sorbonne Univ, Dept Radiat Oncol, Pitie Salpetriere Hosp, AP HP, 47-83 Blvd Hop, F-75651 Paris 13, France
[2] Sorbonne Univ, Neurosurg Dept, Pitie Salpetriere Hosp, AP HP, Paris, France
[3] PSE SANTE SERAMED, Radiat Protect & Nucl Safety Inst, Fontenay Aux Roses, France
关键词
Stereotactic radiosurgery; Multiple brain metastases; Single-isocenter; Gammaknife; Gradient index; Dose fall-off; Target volume effect; STEREOTACTIC RADIOSURGERY; VMAT; INDEX; PLANS;
D O I
10.1186/s13014-021-01766-w
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose To compare linac-based mono-isocentric radiosurgery with Brainlab Elements Multiple Brain Mets (MBM) SRS and the Gamma Knife using a specific statistical method and to analyze the dosimetric impact of the target volume geometric characteristics. A dose fall-off analysis allowed to evaluate the Gradient Index relevancy for the dose spillage characterization. Material and methods Treatments were planned on twenty patients with three to nine brain metastases with MBM 2.0 and GammaPlan 11.0. Ninety-five metastases ranging from 0.02 to 9.61 cc were included. Paddick Index (PI), Gradient Index (GI), dose fall-off, volume of healthy brain receiving more than 12 Gy (V-12Gy) and DVH were used for the plan comparison according to target volume, major axis diameter and Sphericity Index (SI). The multivariate regression approach allowed to analyze the impact of each geometric characteristic keeping all the others unchanged. A parallel study was led to evaluate the impact of the isodose line (IDL) prescription on the MBM plan quality. Results For mono-isocentric linac-based radiosurgery, the IDL around 70-75% was the best compromise found. For both techniques, the GI and the dose fall-off decreased with the target volume. In comparison, PI was slightly improved with MBM for targets < 1 cc or SI > 0.78. GI was improved with GP for targets < 2.5 cc. The V-12Gy was higher with MBM for lesions > 0.4 cc or SI < 0.84 and exceeded 10 cc for targets > 5 cc against 6.5 cc with GP. The presence of OAR close to the PTV had no impact on the dose fall off values. The dose fall-off was higher for volumes < 3.8 cc with GP which had the sharpest dose fall-off in the infero-superior direction up to 30%/mm. The mean beam-on time was 94 min with GP against 13 min with MBM. Conclusions The dose fall-off and the V-12Gy were more relevant indicators than the GI for the low dose spillage assessment. Both evaluated techniques have comparable plan qualities with a slightly improved selectivity with MBM for smaller lesions but with a healthy tissues sparing slightly favorable to GP at the expense of a considerably longer irradiation time. However, a higher healthy tissue exposure must be considered for large volumes in MBM plans.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Dosimetric study between a single isocenter dynamic conformal arc therapy technique and Gamma Knife radiosurgery for multiple brain metastases treatment: impact of target volume geometrical characteristics
    Michel Chea
    Karen Fezzani
    Julian Jacob
    Marguerite Cuttat
    Mathilde Croisé
    Jean-Marc Simon
    Loïc Feuvret
    Charles-Ambroise Valery
    Philippe Maingon
    Mohamed-Amine Benadjaoud
    Catherine Jenny
    Radiation Oncology, 16
  • [2] Dosimetric Study of Automatic Brain Metastases Planning in Comparison with Conventional Multi-Isocenter Dynamic Conformal Arc Therapy and Gamma Knife Radiosurgery for Multiple Brain Metastases
    Mori, Yoshimasa
    Kaneda, Naoki
    Hagiwara, Masahiro
    Ishiguchi, Tuneo
    CUREUS, 2016, 8 (11):
  • [3] A Treatment Planning Strategy of Single Isocenter Multiple Target Stereotactic Radiosurgery for Multiple Brain Metastases Using Dynamic Conformal Arc Technique
    Kim, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E335 - E336
  • [4] Single Isocenter Radiosurgery for the Simultaneous Treatment of Multiple Brain Metastases: Volumetric Modulated Arc Therapy Or Dynamic Conformal Arc?
    Maurer, J.
    Sintay, B.
    Manning, M.
    Wiant, D.
    Liu, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3580 - 3580
  • [5] Dosimetric Comparison Between a Single Isocenter Dynamic Conformal Arc Treatment Technique and the CyberKnife System for Multiple Brain Metastases SRS
    Liu, J.
    Wang, L.
    Chen, X.
    Lin, T.
    Ma, C.
    MEDICAL PHYSICS, 2022, 49 (06) : E961 - E961
  • [6] Simultaneous stereotactic Radiosurgery of multiple Metastases with "single-isocenter dynamic conformal arc" Therapy
    Bodensohn, R.
    Kaempfel, A. -L
    Fleischmann, D. F.
    Hofmaier, J.
    Hadi, I
    Garny, S.
    Reiner, M.
    Corradini, S.
    Forbrig, R.
    Thon, N.
    Belka, C.
    Niyazi, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2020, 196 (SUPPL 1) : S126 - S127
  • [7] Stereotactic radiosurgery with single-isocenter dynamic arc therapy of multiple brain metastases
    Bodensohn, R.
    Kaempfel, A.
    Fleischmann, D. F.
    Hofmaier, J.
    Hadi, I.
    Garny, S.
    Reiner, M.
    Corradini, S.
    Forbrig, R.
    Thon, N.
    Belka, C.
    Niyazi, M.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S470 - S471
  • [8] Dosimetric Comparison of Volumetric-Modulated Arc Therapy and Dynamic Conformal Arc Therapy in Three-fraction Single-isocenter Stereotactic Radiosurgery for Multiple Brain Metastases
    Turkkan, Gorkem
    Bilici, Nazli
    Sertel, Huseyin
    Tavli, Busra
    Ozkirim, Muge
    Fayda, Merdan
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2022, 37 (01): : 67 - 73
  • [9] Volumetric Arc Therapy (RapidArc) vs Gamma Knife Radiosurgery for Multiple Brain Metastases: Not Only a Dosimetric Issue
    Fiorentino, Alba
    Levra, Niccolo Giaj
    Mazzola, Rosario
    Fersino, Sergio
    Ricchetti, Francesco
    Alongi, Filippo
    NEUROSURGERY, 2015, 77 (02) : E310 - E310
  • [10] Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA)
    Huang, Yimei
    Chin, Karen
    Robbins, Jared R.
    Kim, Jinkoo
    Li, Haisen
    Amro, Hanan
    Chetty, Indrin J.
    Gordon, James
    Ryu, Samuel
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) : 128 - 132