Estimating junction temperature of high-flux white LEDs

被引:21
|
作者
Narendran, N [1 ]
Gu, Y [1 ]
Hosseinzadeh, R [1 ]
机构
[1] Rensselaer Polytech Inst, Lighting Res Ctr, Troy, NY 12180 USA
关键词
D O I
10.1117/12.537628
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Performance of white light LEDs has improved significantly over the past few years. White LEDs are typically created by incorporating a layer of phosphor over the GaN-based blue emitter. Heat at the p-n junction seems to be the major factor that influences light output degradation in these devices. In an earlier paper, the principal authors of this manuscript demonstrated that the junction temperature of white LEDs could be measured from the (W/B) ratio, where W represents the total radiant energy of the white LED spectrum, and B represents the radiant energy within the blue emission peak. In that earlier study, the concept was verified using commercially available 5-mm type white LEDs. The goal of the study presented here was to evaluate whether the (W/B) ratio could be used to estimate junction temperature of new high-flux white LEDs. The results show that (W/B) ratio is proportional to the junction temperature of the high-flux white LED; however, the proportionality constants are different for the different white LED types.
引用
收藏
页码:158 / 160
页数:3
相关论文
共 50 条
  • [41] HIGH-FLUX SOLAR EXPERIMENTAL FACILITIES
    MARSHALL, BW
    MULHOLLAND, GP
    BROWN, CT
    HAYS, R
    HIGH TEMPERATURE SCIENCE, 1980, 13 (1-4): : 5 - 20
  • [42] UREA KINETICS IN HIGH-FLUX HEMODIALYSIS
    PROBST, W
    FIKLOCKI, C
    BINSWANGER, U
    KIDNEY INTERNATIONAL, 1991, 39 (06) : 1329 - 1329
  • [43] IMPORTANCE OF ENDOTOXINS IN HIGH-FLUX DIALYSIS
    SMOLLICH, BP
    FALKENHAGEN, D
    SCHNEIDEWIND, J
    MITZNER, S
    KLINKMANN, H
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1991, 6 : 83 - 85
  • [44] High-Flux Irradiation of Open Samples
    J. Casta
    R. Gwozdz
    P. Katrik
    F. Grass
    Journal of Radioanalytical and Nuclear Chemistry, 2000, 244 : 349 - 354
  • [45] The NIST high-flux backscattering spectrometer
    R.M. Dimeo
    Z. Chowdhuri
    A. Meyer
    P.M. Gehring
    D.A. Neumann
    Applied Physics A, 2002, 74 : s311 - s313
  • [46] High-flux magnetorheology at elevated temperatures
    Ocalan, Murat
    McKinley, Gareth H.
    RHEOLOGICA ACTA, 2013, 52 (07) : 623 - 641
  • [47] HIGH-FLUX GRAPHITE RESISTANCE HEATERS
    BABBE, E
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1967, 10 (01): : 145 - &
  • [48] VANCOMYCIN PHARMACOKINETICS IN HIGH-FLUX HEMODIALYSIS
    BARTH, RH
    DEVINCENZO, N
    ZARA, AC
    BERLYNE, GM
    CLINICAL RESEARCH, 1990, 38 (02): : A339 - A339
  • [49] HIGH-FLUX (HF) HEMODIALYSIS (HD)
    ACCHIARDO, S
    BURK, L
    BANNISTER, D
    KIDNEY INTERNATIONAL, 1987, 31 (01) : 226 - 226
  • [50] RAY TRACING OF A HIGH-FLUX BEAMLINE
    BAHRDT, J
    SCHWENTNER, N
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 216 (1-2): : 237 - 239