Performance of white light LEDs has improved significantly over the past few years. White LEDs are typically created by incorporating a layer of phosphor over the GaN-based blue emitter. Heat at the p-n junction seems to be the major factor that influences light output degradation in these devices. In an earlier paper, the principal authors of this manuscript demonstrated that the junction temperature of white LEDs could be measured from the (W/B) ratio, where W represents the total radiant energy of the white LED spectrum, and B represents the radiant energy within the blue emission peak. In that earlier study, the concept was verified using commercially available 5-mm type white LEDs. The goal of the study presented here was to evaluate whether the (W/B) ratio could be used to estimate junction temperature of new high-flux white LEDs. The results show that (W/B) ratio is proportional to the junction temperature of the high-flux white LED; however, the proportionality constants are different for the different white LED types.
引用
收藏
页码:158 / 160
页数:3
相关论文
共 50 条
  • [21] BIOCOMPATIBILITY OF HIGH-FLUX MEMBRANES
    PUTZ, D
    BARNAS, U
    LUGER, A
    MAYER, G
    WOLOSZCZUK, W
    GRAF, H
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1992, 15 (08): : 456 - 460
  • [22] Warning of high-flux hemodialysis
    Takenaka, T
    Kobayashi, K
    Suzuki, H
    RENAL FAILURE, 2001, 23 (06) : 819 - 825
  • [23] THE HIGH-FLUX BEAMLINE AT THE ESRF
    BOSECKE, P
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01): : 438 - 441
  • [24] HIGH-FLUX BREMSSTRAHLUNG SOURCE
    LABRIE, JP
    FUNK, LW
    GOWANS, S
    MCKEOWN, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 242 (03): : 359 - 363
  • [25] High-flux MFI membranes
    Hedlund, J
    Sterte, J
    Anthonis, M
    Bons, AJ
    Carstensen, B
    Corcoran, N
    Cox, D
    Deckman, H
    De Gijnst, W
    de Moor, PP
    Lai, F
    McHenry, J
    Mortier, W
    Reinoso, J
    MICROPOROUS AND MESOPOROUS MATERIALS, 2002, 52 (03) : 179 - 189
  • [26] Double high-flux Hemodiafiltration
    Von Albertini, Beat
    HEMODIAFILTRATION, 2007, 158 : 161 - 168
  • [27] β-trace protein is highly removed during haemodialysis with high-flux and super high-flux membranes
    Donadio, Carlo
    Tognotti, Danika
    Caponi, Laura
    Paolicchi, Aldo
    BMC NEPHROLOGY, 2017, 18
  • [28] β-trace protein is highly removed during haemodialysis with high-flux and super high-flux membranes
    Carlo Donadio
    Danika Tognotti
    Laura Caponi
    Aldo Paolicchi
    BMC Nephrology, 18
  • [29] Development of a High-Flux Solar Simulator for Experimental Testing of High-Temperature Applications
    Milanese, Marco
    Colangelo, Gianpiero
    de Risi, Arturo
    ENERGIES, 2021, 14 (11)
  • [30] All high-flux membranes are equal but some high-flux membranes are less equal than others
    Vanholder, Raymond
    Pedrini, Luciano A.
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2008, 23 (05) : 1481 - 1483