A Simple and Disposable Sampler for Inhalable Aerosol

被引:11
|
作者
L'Orange, Christian [1 ]
Anderson, Kimberly [1 ]
Sleeth, Darrah [2 ]
Anthony, T. Renee [3 ]
Volckens, John [1 ]
机构
[1] Colorado State Univ, Dept Mech Engn, Ft Collins, CO 80526 USA
[2] Univ Utah, Dept Family & Prevent Med, Salt Lake City, UT 84108 USA
[3] Univ Iowa, Dept Occupat & Environm Hlth, 145 Riverside Dr, Iowa City, IA 52242 USA
来源
ANNALS OF OCCUPATIONAL HYGIENE | 2016年 / 60卷 / 02期
关键词
air pollution; exposure; low cost; particulate matter; sampling efficiency; wall deposits; AIR MOVEMENT ENVIRONMENTS; RESPIRATORY SYMPTOMS; AUTOMOBILE WORKERS; WIND SPEEDS; DISEASE; PERFORMANCE; BURDEN; DUST; RISK; EFFICIENCY;
D O I
10.1093/annhyg/mev065
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The state-of-the-art for personal sampling for inhalable aerosol hazards is constrained by issues of sampler cost and complexity; these issues have limited the adoption and use of some samplers by practicing hygienists. Thus, despite the known health effects of inhalable aerosol hazards, personal exposures are routinely assessed for only a small fraction of the at-risk workforce. To address the limitations of current technologies for inhalable aerosol sampling, a disposable inhalable aerosol sampler was developed and evaluated in the laboratory. The new sampler is designed to be less expensive and simpler to use than existing technologies. The sampler incorporates a lightweight internal capsule fused to the sampling filter. This capsule-filter assembly allows for the inclusion of particles deposited on the internal walls and inlet, thus minimizing the need to wash or wipe the interior sampling cassette when conducting gravimetric analyses. Sampling efficiency and wall losses were tested in a low-velocity wind tunnel with particles ranging from 9.5 to 89.5 mu m. The results were compared to the proposed low-velocity inhalability criterion as well as published data on the IOM sampler. Filter weight stability and time-to-equilibrium were evaluated as these factors affect the practicality of a design. Preliminary testing of the new sampler showed good agreement with both the IOM and the proposed low-velocity inhalability curve. The capsule and filter assemblies reached equilibrium within 25h of manufacturing when conditioned at elevated temperatures. After reaching equilibrium, the capsule-filter assemblies were stable within 0.01mg.
引用
收藏
页码:150 / 160
页数:11
相关论文
共 50 条
  • [41] Respirable aerosol sampler accuracy measurement
    Bartley, D.L., 1600, Publ by Pergamon Press Inc, Tarrytown, NY, United States (25):
  • [42] An in vitro analysis of pulmonary deliverability of inhalable solutions and inhalable aerosol products dispersed in ventilator circuit
    Okamoto, Hirokazu
    Takeda, Yuri
    Okuda, Tomoyuki
    AEROSOL SCIENCE AND TECHNOLOGY, 2025, 59 (04) : 388 - 401
  • [43] Laboratory Study of Selected Personal Inhalable Aerosol Samplers
    Gorner, Peter
    Simon, Xavier
    Wrobel, Richard
    Kauffer, Edmond
    Witschger, Olivier
    ANNALS OF OCCUPATIONAL HYGIENE, 2010, 54 (02): : 165 - 187
  • [44] DISPOSABLE AEROSOL TISSUE ADHESIVE SPRAY
    MATSUMOTO, T
    HARDAWAY, RM
    PANI, KC
    MARGETIS, PM
    ARCHIVES OF SURGERY, 1967, 95 (04) : 685 - +
  • [45] Design and Computational Fluid Dynamics Investigation of a Personal, High Flow Inhalable Sampler
    Anthony, T. Renee
    Landazuri, Andrea C.
    Van Dyke, Mike
    Volckens, John
    ANNALS OF OCCUPATIONAL HYGIENE, 2010, 54 (04): : 427 - 442
  • [46] A Simple Sampler for the Horseshoe Estimator
    Makalic, Enes
    Schmidt, Daniel F.
    IEEE SIGNAL PROCESSING LETTERS, 2016, 23 (01) : 179 - 182
  • [47] SIMPLE WATER AND PLANKTON SAMPLER
    BLAKAR, IA
    FRESHWATER BIOLOGY, 1978, 8 (06) : 533 - &
  • [48] A SIMPLE AND EFFICIENT DRIFT SAMPLER
    FIELDDODGSON, MS
    NEW ZEALAND JOURNAL OF MARINE AND FRESHWATER RESEARCH, 1985, 19 (02) : 167 - 172
  • [49] A SIMPLE AUTOMATIC SAMPLER FOR WATER
    WILKINSON, R
    BRIGGS, R
    CHEMISTRY & INDUSTRY, 1953, (34) : 886 - 887
  • [50] Comparison of a simplified and full-size mannequin for the evaluation of inhalable sampler performance
    Kennedy, NJ
    Tatyan, K
    Hinds, WC
    AEROSOL SCIENCE AND TECHNOLOGY, 2001, 35 (01) : 564 - 568