A Simple and Disposable Sampler for Inhalable Aerosol

被引:11
|
作者
L'Orange, Christian [1 ]
Anderson, Kimberly [1 ]
Sleeth, Darrah [2 ]
Anthony, T. Renee [3 ]
Volckens, John [1 ]
机构
[1] Colorado State Univ, Dept Mech Engn, Ft Collins, CO 80526 USA
[2] Univ Utah, Dept Family & Prevent Med, Salt Lake City, UT 84108 USA
[3] Univ Iowa, Dept Occupat & Environm Hlth, 145 Riverside Dr, Iowa City, IA 52242 USA
来源
ANNALS OF OCCUPATIONAL HYGIENE | 2016年 / 60卷 / 02期
关键词
air pollution; exposure; low cost; particulate matter; sampling efficiency; wall deposits; AIR MOVEMENT ENVIRONMENTS; RESPIRATORY SYMPTOMS; AUTOMOBILE WORKERS; WIND SPEEDS; DISEASE; PERFORMANCE; BURDEN; DUST; RISK; EFFICIENCY;
D O I
10.1093/annhyg/mev065
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
The state-of-the-art for personal sampling for inhalable aerosol hazards is constrained by issues of sampler cost and complexity; these issues have limited the adoption and use of some samplers by practicing hygienists. Thus, despite the known health effects of inhalable aerosol hazards, personal exposures are routinely assessed for only a small fraction of the at-risk workforce. To address the limitations of current technologies for inhalable aerosol sampling, a disposable inhalable aerosol sampler was developed and evaluated in the laboratory. The new sampler is designed to be less expensive and simpler to use than existing technologies. The sampler incorporates a lightweight internal capsule fused to the sampling filter. This capsule-filter assembly allows for the inclusion of particles deposited on the internal walls and inlet, thus minimizing the need to wash or wipe the interior sampling cassette when conducting gravimetric analyses. Sampling efficiency and wall losses were tested in a low-velocity wind tunnel with particles ranging from 9.5 to 89.5 mu m. The results were compared to the proposed low-velocity inhalability criterion as well as published data on the IOM sampler. Filter weight stability and time-to-equilibrium were evaluated as these factors affect the practicality of a design. Preliminary testing of the new sampler showed good agreement with both the IOM and the proposed low-velocity inhalability curve. The capsule and filter assemblies reached equilibrium within 25h of manufacturing when conditioned at elevated temperatures. After reaching equilibrium, the capsule-filter assemblies were stable within 0.01mg.
引用
收藏
页码:150 / 160
页数:11
相关论文
共 50 条
  • [1] Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery
    Lee, Eun Gyung
    Grimson, Peter J.
    Chisholm, William P.
    Kashon, Michael L.
    He, Xinjian
    L'Orange, Christian
    Volckens, John
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2019, 16 (03) : 250 - 257
  • [2] Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler
    Stewart, Justin
    Sleeth, Darrah K.
    Handy, Rod G.
    Pahler, Leon F.
    Anthony, T. Renee
    Volckens, John
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (03) : 207 - 213
  • [3] Evaluation of a 25-mm disposable sampler relative to the inhalable aerosol convention
    Ben Borsh, F.
    Sleeth, Darrah K.
    Handy, Rod G.
    Pahler, Leon F.
    Andrews, Ronnee
    Ashley, Kevin
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2019, 16 (09) : 634 - 642
  • [4] Lung Deposition Sampler for Inhalable Aerosol
    Clark, Philip
    Koehler, Kirsten
    Volckens, John
    INHALED PARTICLES X, 2009, 151
  • [5] Inhalable aerosol selector for the CIP 10 personal aerosol sampler
    Gorner, P.
    Wrobel, R.
    Roger, F.
    Fabries, J.-F.
    Journal of Aerosol Science, 1999, 30 (Suppl. 1)
  • [6] Performance characteristics of the button personal inhalable aerosol sampler
    Aizenberg, V
    Grinshpun, SA
    Willeke, K
    Smith, J
    Baron, PA
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 2000, 61 (03): : 398 - 404
  • [7] Improvements to the design and performance of an ambient inhalable aerosol sampler
    Upton, S.L.
    Mark, D.
    Hall, D.J.
    Journal of Aerosol Science, 1992, 23 (SUPPL 1)
  • [8] A collaborative European study of personal inhalable aerosol sampler performance
    Kenny, LC
    Aitken, R
    Chalmers, C
    Fabries, JF
    GonzalezFernandez, E
    Kromhout, H
    Liden, G
    Mark, D
    Riediger, G
    Prodi, V
    ANNALS OF OCCUPATIONAL HYGIENE, 1997, 41 (02): : 135 - 153
  • [9] High efficiency CIP 10-I personal inhalable aerosol sampler
    Gorner, P.
    Wrobel, R.
    Simon, X.
    INHALED PARTICLES X, 2009, 151
  • [10] High efficiency CIP 10-I personal inhalable aerosol sampler
    Gorner, P.
    Wrobel, R.
    Simon, X.
    INHALED PARTICLES X, 2009, 151