Evaluation of a 25-mm disposable sampler relative to the inhalable aerosol convention

被引:2
|
作者
Ben Borsh, F. [1 ]
Sleeth, Darrah K. [1 ]
Handy, Rod G. [1 ]
Pahler, Leon F. [1 ]
Andrews, Ronnee [2 ]
Ashley, Kevin [3 ]
机构
[1] Univ Utah, Rocky Mt Ctr Occupat & Environm Hlth, Dept Family & Prevent Med, Salt Lake City, UT 84108 USA
[2] NIOSH, Div Appl Res & Technol, Cincinnati, OH 45226 USA
[3] Ashley Analyt Associates, Amado, AZ USA
关键词
Aerosol sampler; closed-faced cassette; inhalable particulate matter; IOM sampler; wind tunnel; PARTICULATE MATTER; CLOSED-FACE; AIR; PERFORMANCE; EFFICIENCY; CASSETTES; EXPOSURE;
D O I
10.1080/15459624.2019.1632463
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An ideal inhalable aerosol sampler for occupational exposure monitoring would have a sampling efficiency that perfectly matches the inhalable particulate matter (IPM) criterion. Two common aerosol samplers in use worldwide are the closed-face cassette (CFC) and the Institute of Occupational Medicine (IOM) sampler. However, the CFC is known to under-sample, with near zero sampling efficiency for particles >30 mu m, whereas the IOM, considered by many to be the "gold standard" in inhalable samplers, has been shown to over-sample particles >60 mu m. A new sampler in development incorporates characteristics of both the CFC and the IOM. Like the CFC, it would be disposable, have a simple design, and is intended to be oriented at a 45 degrees downward angle. Like the IOM, the new sampler has a 15-mm inlet diameter and incorporates a 25-mm filter cassette with a protruding lip. The IOM is oriented at 0 degrees to the horizontal, so it is hypothesized that orienting the new sampler at similar to 45 degrees downward angle will reduce oversampling of larger particles. In comparison, the CFC's inlet diameter is 4 mm; increasing the size of the inlet should allow the new sampler to have an increased efficiency relative to the CFC for all particles. A unique characteristic of the new sampler is the incorporation of a one-piece capsule-style filter that mimics the IOM's cassette but is made of disposable material. Seven different sizes of alumina particles (mean aerodynamic diameters from 4.9-62.4 mu m) were tested (total = 124 samples collected). For each test, six samplers were placed on a manikin located inside a wind tunnel operated at 0.2 m/sec. Results indicated that the new sampler improved on the CFC for smaller particles, providing a larger range for which it matches the IPM criterion, up to 44.3 mu m. However, the efficiency was significantly lower in comparison to the IPM criterion for particle sizes above 60 mu m. Overall, the new sampler showed promise, but additional modifications may help improve sampling efficiency for larger particles.
引用
收藏
页码:634 / 642
页数:9
相关论文
共 6 条
  • [1] A Simple and Disposable Sampler for Inhalable Aerosol
    L'Orange, Christian
    Anderson, Kimberly
    Sleeth, Darrah
    Anthony, T. Renee
    Volckens, John
    ANNALS OF OCCUPATIONAL HYGIENE, 2016, 60 (02): : 150 - 160
  • [2] Performance evaluation of disposable inhalable aerosol sampler at a copper electrorefinery
    Lee, Eun Gyung
    Grimson, Peter J.
    Chisholm, William P.
    Kashon, Michael L.
    He, Xinjian
    L'Orange, Christian
    Volckens, John
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2019, 16 (03) : 250 - 257
  • [3] Assessment of increased sampling pump flow rates in a disposable, inhalable aerosol sampler
    Stewart, Justin
    Sleeth, Darrah K.
    Handy, Rod G.
    Pahler, Leon F.
    Anthony, T. Renee
    Volckens, John
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2017, 14 (03) : 207 - 213
  • [4] Evaluation of the use of an SKC button inhalable aerosol sampler with a Grimm aerosol monitor to determine air concentrations of subtilisin
    Cross, Jason B.
    Larson, Rodney R.
    Pahler, Leon F.
    Sleeth, Darrah K.
    JOURNAL OF CHEMICAL HEALTH & SAFETY, 2014, 21 (06): : 4 - 13
  • [5] Intersampler Field Comparison of Respicon®, IOM, and Closed-Face 25-mm Personal Aerosol Samplers During Primary Production of Aluminium
    Skaugset, Nils Petter
    Ellingsen, Dag G.
    Noto, Hilde
    Jordbekken, Lars
    Thomassen, Yngvar
    ANNALS OF OCCUPATIONAL HYGIENE, 2013, 57 (08): : 1054 - 1064
  • [6] Nerve regeneration across a 25-mm gap bridged by a polyglycolic acid collagen tube: A histological and electrophysiological evaluation of regenerated nerves
    Kiyotani, T
    Teramachi, M
    Takimoto, Y
    Nakamura, T
    Shimizu, Y
    Endo, K
    BRAIN RESEARCH, 1996, 740 (1-2) : 66 - 74