Safety of smartwatches and their chargers in patients with cardiac implantable electronic devices

被引:6
|
作者
Tzeis, Stylianos [1 ]
Asvestas, Dimitrios [1 ]
Moraitis, Nektarios [2 ]
Vardas, Emmanuel P. [1 ]
Mililis, Panagiotis [3 ]
Letsas, Konstantinos [3 ]
Kouvelas, Konstantinos [1 ]
Nikita, Konstantina S. [2 ]
Vardas, Panos [1 ]
机构
[1] Mitera Gen Hosp, Dept Cardiol, Hygeia Grp, Erithrou Stavrou 6, Athens, Greece
[2] Natl Tech Univ Athens, Sch Elect & Comp Engn, Athens, Greece
[3] Evangelismos Gen Hosp, Dept Cardiol, Electrophysiol Lab, Athens, Greece
来源
EUROPACE | 2021年 / 23卷 / 01期
关键词
Electromagnetic interference; Smartwatch; Cardiac implantable electronic device;
D O I
10.1093/europace/euaa220
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Cardiac implantable electronic devices (CIEDs) are susceptible to electromagnetic interference (EMI). Smartwatches and their chargers could be a possible source of EMI. We sought to assess whether the latest generation smartwatches and their chargers interfere with proper CIED function. Methods and results We included consecutive CIED recipients in two centres. We tested two latest generation smartwatches (Apple Watch and Samsung Galaxy Watch) and their charging cables for potential EMI. The testing was performed under continuous electrocardiogram recording and real-time device telemetry, with nominal and 'worst-case' settings. In vitro magnetic field measurements were performed to assess the emissions from the tested devices, initially in contact with the probe and then at a distance of 10 cm and 20 cm. In total, 171 patients with CIEDs (71.3% pacemakers-28.7% implantable cardioverter-defibrillators) from five manufacturers were enrolled (63.2% males, 74.8 +/- 11.4 years), resulting in 684 EMI tests. No EMI was identified in any patient either under nominal or 'worst-case scenario' programming. The peak magnetic flux density emitted by the smartwatches was similar to the background noise level (0.81 mu T) even when in contact with the measuring probe. The respective values for the chargers were 4.696 mu T and 4.299 mu T for the Samsung and Apple chargers, respectively, which fell at the background noise level when placed at 20 cm and 10 cm, respectively. Conclusion Two latest generation smartwatches and their chargers resulted in no EMI in CIED recipients. The absence of EMI in conjunction with the extremely low intensity of magnetic fields emitted by these devices support the safety of their use by CIED patients.
引用
收藏
页码:99 / 103
页数:5
相关论文
共 50 条
  • [21] Sudden cardiac arrest in patients with cardiac implantable electronic devices
    Sharifzadehgan, A.
    Bougouin, W.
    Narayanan, K.
    Dumas, F.
    Waldmann, V.
    Gandjbakhch, E.
    Aissaoui, N.
    Algalarrondo, V.
    Extramiana, F.
    Lellouche, N.
    Cariou, A.
    Jouven, X.
    Marijon, E.
    [J]. EUROPEAN HEART JOURNAL, 2018, 39 : 213 - 213
  • [22] Cardiac Implantable Electronic Devices
    Al-Khatib, Sana M.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2024, 390 (05): : 442 - 454
  • [23] Perioperative management of patients with cardiac implantable electronic devices
    Kim, Minsu
    Kwon, Chang Hee
    [J]. KOREAN JOURNAL OF ANESTHESIOLOGY, 2024, 77 (03) : 306 - 315
  • [24] Management of Radiotherapy Patients with Cardiac Implantable Electronic Devices
    Miften, Moyed
    Mihailidis, D.
    Kry, S.
    Miften, M.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3240 - 3240
  • [25] Perioperative management of patients with cardiac implantable electronic devices
    Stone, M. E.
    Salter, B.
    Fischer, A.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 : 16 - 26
  • [26] Use of Implantable Electronic Devices in Patients With Cardiac Amyloidosis
    John, Roy M.
    Stern, David L.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2020, 36 (03) : 408 - 415
  • [27] Perioperative Assessment of Patients With Cardiac Implantable Electronic Devices
    Castillo, Javier G.
    Silvay, George
    Viles-Gonzalez, Juan
    [J]. MOUNT SINAI JOURNAL OF MEDICINE, 2012, 79 (01): : 25 - 33
  • [28] Perioperative management of patients with cardiac implantable electronic devices
    Bryant, H. C.
    Roberts, P. R.
    Diprose, P.
    [J]. BJA EDUCATION, 2016, 16 (11) : 388 - 396
  • [29] Radiation therapy in patients with cardiac implantable electronic devices
    Niedziela, Jacek T.
    Blamek, Slawomir
    Gadula-Gacek, Elibieta
    Gorol, Jaroslaw
    Kurek, Anna
    Witek, Mateusz
    Wojtaszczyk, Adam
    Plaza, Przemyslaw
    Miszczyk, Leszek
    Gasior, Mariusz
    Tajstra, Mateusz
    [J]. KARDIOLOGIA POLSKA, 2021, 79 (02) : 156 - 160
  • [30] Endoscopic Electrosurgery in Patients with Cardiac Implantable Electronic Devices
    Baeg, Myong Ki
    Kim, Sang-Woo
    Ko, Sun-Hye
    Lee, Yoon Bum
    Hwang, Seawon
    Lee, Bong-Woo
    Choi, Hye Jin
    Park, Jae Myung
    Lee, In-Seok
    Oh, Yong-Seog
    Choi, Myung-Gyu
    [J]. CLINICAL ENDOSCOPY, 2016, 49 (02) : 176 - 181