Measurement Errors Related to Contact Angle Analysis of Hydrogel and Silicone Hydrogel Contact Lenses

被引:44
|
作者
Read, Michael L. [1 ]
Morgan, Philip B. [1 ]
Maldonado-Codina, Carole [1 ]
机构
[1] Univ Manchester, Fac Life Sci, Manchester, Lancs, England
基金
英国医学研究理事会;
关键词
contact angle; contact lens; hydrogel; silicone hydrogel; measurement error; coefficient of repeatability; BACTERIAL ADHESION; WETTABILITY; WEAR; WORN;
D O I
10.1002/jbm.b.31442
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work sought to undertake a comprehensive investigation of the measurement errors associated with contact angle assessment of curved hydrogel contact lens surfaces. The contact angle coefficient of repeatability (COR) associated with three measurement conditions (image analysis COR, intralens COR, and interlens COR) was determined by measuring the contact angles (using both sessile drop and captive bubble methods) for three silicone hydrogel lenses (senofilcon A, balafilcon A, lotrafilcon A) and one conventional hydrogel lens (etafilcon A). Image analysis COR values were about 2 degrees, whereas intralens COR values (95% confidence intervals) ranged from 4.0 degrees (3.3 degrees, 4.7 degrees) (lotrafilcon A, captive bubble) to 10.2 degrees (8.4 degrees, 12.1 degrees) (senofilcon A, sessile drop). Interlens COR values ranged from 4.5 degrees (3.7 degrees, 5.2 degrees) (lotrafilcon A, captive bubble) to 16.5 degrees (13.6 degrees, 19.4 degrees) (senofilcon A, sessile drop). Measurement error associated with image analysis was shown to be small as an absolute measure, although proportionally more significant for lenses with low contact angle. Sessile drop contact angles were typically less repeatable than captive bubble contact angles. For sessile drop measures, repeatability was poorer with the silicone hydrogel lenses when compared with the conventional hydrogel lens; this phenomenon was not observed for the captive bubble method, suggesting that methodological factors related to the sessile drop technique (such as surface dehydration and blotting) may play a role in the increased variability of contact angle measurements observed with silicone hydrogel contact lenses. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 91B: 662-668, 2009
引用
收藏
页码:662 / 668
页数:7
相关论文
共 50 条
  • [1] Dynamic Contact Angle Analysis of Silicone Hydrogel Contact Lenses
    Read, Michael Leonard
    Morgan, Philip Bruce
    Kelly, Jeremiah Michael
    Maldonado-Codina, Carole
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2011, 26 (01) : 85 - 99
  • [2] Are Silicone Hydrogel Contact Lenses More Comfortable Than Hydrogel Contact Lenses?
    Guillon, Michel
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 86 - 92
  • [3] Analysis of Lipid Extraction From Hydrogel and Silicone Hydrogel Contact Lenses
    Pucker, A. D.
    Thangavelu, M.
    Nichols, J. J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] The effect of hydrogel and silicone hydrogel contact lenses on the measurement of intraocular pressure with rebound tonometry
    Zeri, Fabrizio
    Calcatelli, Paolo
    Donini, Bernardo
    Lupelli, Luigi
    Zarrilli, Luciana
    Swann, Peter G.
    CONTACT LENS & ANTERIOR EYE, 2011, 34 (06): : 260 - 265
  • [5] Comparison of Silicone Hydrogel and Hydrogel Daily Disposable Contact Lenses
    Diec, Jennie
    Tilia, Daniel
    Thomas, Varghese
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S167 - S172
  • [6] Contact Lens Lipid Spoliation of Hydrogel and Silicone Hydrogel Lenses
    Maissa, Cecile
    Guillon, Michel
    Cockshott, Nik
    Garofalo, Renee J.
    Lemp, Jessie M.
    Boclair, Joseph W.
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (09) : 1071 - 1083
  • [7] In Vitro Lipid Deposition on Hydrogel and Silicone Hydrogel Contact Lenses
    Pucker, Andrew D.
    Thangavelu, Mirunalni
    Nichols, Jason J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6334 - 6340
  • [8] Measuring the Modulus of Silicone Hydrogel Contact Lenses
    Horst, Caleb R.
    Brodland, Benjamin
    Jones, Lyndon W.
    Brodland, G. Wayne
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (10) : 1468 - 1476
  • [9] Commemorating the Discovery of Silicone Hydrogel Contact Lenses
    Fonn, Desmond
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 1 - 1
  • [10] Transport of Phospholipid in Silicone Hydrogel Contact Lenses
    Pitt, William G.
    Jack, Daniel R.
    Zhao, Yibei
    Nelson, Jared L.
    Pruitt, John D.
    JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2012, 23 (1-4) : 527 - 541