The Malleable Implant Salvage Technique: Infection Outcomes after Mulcahy Salvage Procedure and Replacement of Infected Inflatable Penile Prosthesis with Malleable Prosthesis

被引:54
|
作者
Gross, Martin S. [1 ]
Phillips, Elizabeth A. [1 ]
Balen, Alejandra [1 ]
Eid, J. Francois [2 ]
Yang, Christopher [3 ]
Simon, Ross [3 ]
Martinez, Daniel [3 ]
Carrion, Rafael [3 ]
Perito, Paul [4 ]
Levine, Laurence [5 ]
Greenfield, Jason [6 ]
Munarriz, Ricardo [1 ]
机构
[1] Boston Univ, Med Ctr, Boston, MA 02118 USA
[2] Adv Urol Care, New York, NY USA
[3] USF Morsani Coll Med, Tampa, FL USA
[4] Perito Urol, Coral Gables, FL USA
[5] Rush Med Coll, Chicago, IL 60612 USA
[6] Urol Associates North Texas, Arlington, TX USA
来源
JOURNAL OF UROLOGY | 2016年 / 195卷 / 03期
关键词
penile prosthesis; salvage therapy; infection; erectile dysfunction; ERECTILE DYSFUNCTION; MANAGEMENT;
D O I
10.1016/j.juro.2015.08.091
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Since its introduction in 1996 Mulcahy salvage has significantly improved outcomes for the removal and replacement of infected inflatable penile prostheses. Long-term followup data of Mulcahy salvage show an infection-free rate of 82%. A multicenter retrospective analysis of the malleable implant salvage technique was conducted to assess infection outcomes and the feasibility of conversion from malleable device back to inflatable penile prosthesis. Materials and Methods: This is a retrospective, institutional review board exempt, multi-institution study of 58 patients who underwent Mulcahy salvage with inflatable penile prosthesis removal and replacement with malleable prosthesis. Patient operative notes and charts were extensively reviewed to compile study data. Results: Between 2002 and 2014 a total of 58 patients underwent infected inflatable penile prosthesis removal and replacement with a malleable prosthesis via Mulcahy salvage. Of these patients 54 (93%) have remained infection-free postoperatively. Average patient age was 56.4 years and average operative time was 148 minutes. Postoperative followup (as of May 2015) ranged from 1 month to 84 months. Of the 54 patients 37 retained the malleable prosthesis and 17 (31%) subsequently underwent replacement with an inflatable penile prosthesis. This occurred on average 6.7 months after Mulcahy salvage. Four patients had persistent infection after Mulcahy salvage with the malleable prosthesis and underwent explantation. Conclusions: This retrospective analysis of Mulcahy salvage procedure and replacement of inflatable penile prosthesis with malleable prosthesis shows a high infection-free rate. Additionally, 17 of the 54 patients who remained infection-free were able to successfully undergo subsequent removal of the malleable prosthesis and replacement with an inflatable penile prosthesis. Further prospective studies are needed to compare salvage with malleable vs inflatable penile prosthesis.
引用
收藏
页码:694 / 697
页数:4
相关论文
共 50 条
  • [21] Prevention of infection in revision of penile prostheses by using antibiotic coated prosthesis and Mulcahy salvage protocol
    Wilson, SK
    Henry, GD
    Delk, JR
    Cleves, MA
    JOURNAL OF UROLOGY, 2003, 169 (04): : 325 - 325
  • [22] Clinical Experience with Malleable Penile Implantation for Salvaging Inflatable Implant Infection
    Hsu, G. L.
    Chueh, J.
    JOURNAL OF SEXUAL MEDICINE, 2024, 21
  • [23] SALVAGE REPLACEMENT OF PENILE PROSTHESIS WITH NORMAL SALINE WASHOUT
    Masson, P.
    Eid, J. F.
    JOURNAL OF SEXUAL MEDICINE, 2012, 9 : 191 - 192
  • [24] IMMEDIATE SALVAGE WITH INFLATABLE PENILE PROSTHESIS IN AN INFECTED FIELD: A CONTEMPORARY MULTI-INSTITUTIONAL COHORT
    Jiang, D.
    Barnard, J.
    Choi, E.
    Furr, J.
    Lentz, A.
    van Renterghem, K.
    Selph, P.
    Yafi, F. A.
    JOURNAL OF SEXUAL MEDICINE, 2022, 19 (04): : S64 - S64
  • [25] IMMEDIATE SALVAGE WITH INFLATABLE PENILE PROSTHESIS IN AN INFECTED FIELD: A CONTEMPORARY MULTI-INSTITUTIONAL COHORT
    Jiang, Daniel
    Barnard, John
    Choi, Edward
    Furr, James
    Lentz, Aaron
    van Renterghem, Koenraad
    Selph, Patrick
    Yafi, Faysal A.
    JOURNAL OF UROLOGY, 2021, 206 : E985 - E985
  • [26] IMMEDIATE SALVAGE WITH INFLATABLE PENILE PROSTHESIS IN AN INFECTED FIELD: A CONTEMPORARY MULTI-INSTITUTIONAL COHORT
    Jiang, D.
    Barnard, J.
    Choi, E.
    Furr, J.
    Lentz, A.
    van Renterghem, K.
    Selph, P.
    Yafi, F. A.
    JOURNAL OF SEXUAL MEDICINE, 2022, 19 (05): : S190 - S191
  • [27] Malleable Implant Substitution for the Management of Penile Prosthesis Pump Erosion: A Pilot Study
    Koehler, Tobias
    Modder, Joshua K.
    Dupree, James M.
    Bush, Nicol C.
    McVary, Kevin T.
    JOURNAL OF SEXUAL MEDICINE, 2009, 6 (05): : 1474 - 1478
  • [28] INFLATABLE PENILE PROSTHESIS AND SALVAGE PROTOCOL FOR MECHANICAL FAILURE: IS IT REALLY NECESSARY?
    Bartley, Jamie
    Zimmerman, W. Britt
    Dhabuwala, Chirpryia
    JOURNAL OF SEXUAL MEDICINE, 2012, 9 : 61 - 61
  • [29] Inflatable Penile Prosthesis and Salvage Protocol for Mechanical Failure: Is It Really Necessary?
    Bartley, Jamie
    Zimmerman, W. Britt
    Dhabuwala, Chirpriya B.
    JOURNAL OF SEXUAL MEDICINE, 2012, 9 (08): : 2175 - 2181
  • [30] The importance of the malleable implant salvage technique (MIST) in modern prosthetic urology
    Tatem, Alex