4D Respiratory Motion-Compensated Image Reconstruction of Free-Breathing Radial MR Data With Very High Undersampling

被引:70
|
作者
Rank, Christopher M. [1 ]
Heusser, Thorsten [1 ]
Buzan, Maria T. A. [2 ,3 ,4 ]
Wetscherek, Andreas [1 ]
Freitag, Martin T. [5 ]
Dinkel, Julien [3 ,6 ,7 ]
Kachelriess, Marc [1 ]
机构
[1] German Canc Res Ctr, Med Phys Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[2] Iuliu Hatieganu Univ Med & Pharm, Dept Pneumol, Hasdeu Str 6, Cluj Napoca 400371, Romania
[3] Univ Heidelberg Hosp, Dept Diagnost & Intervent Radiol Nucl Med, Amalienstr 5, D-69126 Heidelberg, Germany
[4] Univ Heidelberg Hosp, Dept Diagnost & Intervent Radiol, Neuenheimer Feld 110, D-69120 Heidelberg, Germany
[5] German Canc Res Ctr, Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[6] TLRC, German Ctr Lung Res DZL, Neuenheimer Feld 430, D-69120 Heidelberg, Germany
[7] Ludwig Maximilians Univ Hosp Munich, Inst Clin Radiol, Marchioninistrasse 15, D-81377 Munich, Germany
关键词
4D MRI; respiratory motion compensation; joint estimation; undersampling; radial sampling; K-T FOCUSS; GENERALIZED RECONSTRUCTION; COMBINATION; STRATEGIES; CT; REGULARIZATION; REGISTRATION; INVERSION; FRAMEWORK; REDUCTION;
D O I
10.1002/mrm.26206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop four-dimensional (4D) respiratory timeresolved MRI based on free-breathing acquisition of radial MR data with very high undersampling. Methods: We propose the 4D joint motion-compensated highdimensional total variation (4D joint MoCo-HDTV) algorithm, which alternates between motion-compensated image reconstruction and artifact-robust motion estimation at multiple resolution levels. The algorithm is applied to radial MR data of the thorax and upper abdomen of 12 free-breathing subjects with acquisition times between 37 and 41 s and undersampling factors of 16.8. Resulting images are compared with compressed sensing-based 4D motion-adaptive spatio-temporal regularization (MASTeR) and 4D high-dimensional total variation (HDTV) reconstructions. Results: For all subjects, 4D joint MoCo-HDTV achieves higher similarity in terms of normalized mutual information and cross-correlation than 4D MASTeR and 4D HDTV when compared with reference 4D gated gridding reconstructions with 8.4 +/- 1.1 times longer acquisition times. In a qualitative assessment of artifact level and image sharpness by two radiologists, 4D joint MoCo-HDTV reveals higher scores (P < 0.05) than 4D HDTV and 4D MASTeR at the same undersampling factor and the reference 4D gated gridding reconstructions, respectively. Conclusions: 4D joint MoCo-HDTV enables time-resolved image reconstruction of free-breathing radial MR data with undersampling factors of 16.8 while achieving low-streak arti-fact levels and high image sharpness. (C) 2016 International Society for Magnetic Resonance in Medicine
引用
下载
收藏
页码:1170 / 1183
页数:14
相关论文
共 50 条
  • [31] An iterative image reconstruction algorithm for 4D PET/CT incorporating respiratory motion correction
    Lamare, F.
    Ledesma-Carbayo, M.
    Kontaxakis, G.
    Santos, A.
    Jarritt, P.
    Mawlawi, O.
    Le Rest, C. Cheze
    Visvikis, D.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S147 - S147
  • [32] Evaluation of a 4D PET image reconstruction method with respiratory motion compensation in a patient study
    Chen, Si
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [33] MULTIRESOLUTION RECONSTRUCTION OF REAL-TIME MRI WITH MOTION COMPENSATED COMPRESSED SENSING: APPLICATION TO 2D FREE-BREATHING CARDIAC MRI
    Royuela-del-Val, J.
    Usman, M.
    Cordero-Grande, L.
    Martin-Fernandez, M.
    Simmross-Wattenberg, F.
    Prieto, C.
    Alberola-Lopez, C.
    2016 IEEE 13TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2016, : 506 - 509
  • [34] A normative database of free-breathing thoracic 4D dynamic MRI images and associated regional respiratory parameters of healthy children
    Tong, Yubing
    Udupa, Jayaram K.
    McDonough, Joseph M.
    Wu, Caiyun
    Akhtar, Yusuf
    Xie, Lipeng
    Alnoury, Mostafa
    Hosseini, Mahdie
    Tong, Leihui
    Gogel, Samantha
    Biko, David M.
    Mayer, Oscar H.
    Anari, Jason B.
    Torigian, Drew A.
    Cahill, Patrick J.
    IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, MEDICAL IMAGING 2024, 2024, 12931
  • [35] Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction
    Stehning, C
    Börnert, P
    Nehrke, K
    Eggers, H
    Stuber, M
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 476 - 480
  • [36] Dosimetric impact of motion in free-breathing and gated lung radiotherapy: A 4D Monte Carlo study of intrafraction and interfraction effects
    Seco, Joao
    Sharp, Greg C.
    Wu, Ziji
    Gierga, David
    Buettner, Florian
    Paganetti, Harald
    MEDICAL PHYSICS, 2008, 35 (01) : 356 - 366
  • [37] Joint estimation of respiratory motion and PET image in 4D PET reconstruction with modeling attenuation map deformation induced by respiratory motion
    Chen, Si
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [38] Free-breathing 3D whole-heart coronary mra using respiratory motion-resolved sparse reconstruction
    Davide Piccini
    Li Feng
    Gabriele Bonanno
    Simone Coppo
    Jérôme Yerly
    Ruth P Lim
    Juerg Schwitter
    Daniel K Sodickson
    Ricardo Otazo
    Matthias Stuber
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [39] Estimating the 4D respiratory lung motion by spatiotemporal registration and super-resolution image reconstruction
    Wu, Guorong
    Wang, Qian
    Lian, Jun
    Shen, Dinggang
    MEDICAL PHYSICS, 2013, 40 (03)
  • [40] Evaluation of a new 4D PET image reconstruction method with respiratory motion compensation in a CHO study
    Chen, Si
    Tsui, Benjamin
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52