4D Respiratory Motion-Compensated Image Reconstruction of Free-Breathing Radial MR Data With Very High Undersampling

被引:70
|
作者
Rank, Christopher M. [1 ]
Heusser, Thorsten [1 ]
Buzan, Maria T. A. [2 ,3 ,4 ]
Wetscherek, Andreas [1 ]
Freitag, Martin T. [5 ]
Dinkel, Julien [3 ,6 ,7 ]
Kachelriess, Marc [1 ]
机构
[1] German Canc Res Ctr, Med Phys Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[2] Iuliu Hatieganu Univ Med & Pharm, Dept Pneumol, Hasdeu Str 6, Cluj Napoca 400371, Romania
[3] Univ Heidelberg Hosp, Dept Diagnost & Intervent Radiol Nucl Med, Amalienstr 5, D-69126 Heidelberg, Germany
[4] Univ Heidelberg Hosp, Dept Diagnost & Intervent Radiol, Neuenheimer Feld 110, D-69120 Heidelberg, Germany
[5] German Canc Res Ctr, Radiol, Neuenheimer Feld 280, D-69120 Heidelberg, Germany
[6] TLRC, German Ctr Lung Res DZL, Neuenheimer Feld 430, D-69120 Heidelberg, Germany
[7] Ludwig Maximilians Univ Hosp Munich, Inst Clin Radiol, Marchioninistrasse 15, D-81377 Munich, Germany
关键词
4D MRI; respiratory motion compensation; joint estimation; undersampling; radial sampling; K-T FOCUSS; GENERALIZED RECONSTRUCTION; COMBINATION; STRATEGIES; CT; REGULARIZATION; REGISTRATION; INVERSION; FRAMEWORK; REDUCTION;
D O I
10.1002/mrm.26206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop four-dimensional (4D) respiratory timeresolved MRI based on free-breathing acquisition of radial MR data with very high undersampling. Methods: We propose the 4D joint motion-compensated highdimensional total variation (4D joint MoCo-HDTV) algorithm, which alternates between motion-compensated image reconstruction and artifact-robust motion estimation at multiple resolution levels. The algorithm is applied to radial MR data of the thorax and upper abdomen of 12 free-breathing subjects with acquisition times between 37 and 41 s and undersampling factors of 16.8. Resulting images are compared with compressed sensing-based 4D motion-adaptive spatio-temporal regularization (MASTeR) and 4D high-dimensional total variation (HDTV) reconstructions. Results: For all subjects, 4D joint MoCo-HDTV achieves higher similarity in terms of normalized mutual information and cross-correlation than 4D MASTeR and 4D HDTV when compared with reference 4D gated gridding reconstructions with 8.4 +/- 1.1 times longer acquisition times. In a qualitative assessment of artifact level and image sharpness by two radiologists, 4D joint MoCo-HDTV reveals higher scores (P < 0.05) than 4D HDTV and 4D MASTeR at the same undersampling factor and the reference 4D gated gridding reconstructions, respectively. Conclusions: 4D joint MoCo-HDTV enables time-resolved image reconstruction of free-breathing radial MR data with undersampling factors of 16.8 while achieving low-streak arti-fact levels and high image sharpness. (C) 2016 International Society for Magnetic Resonance in Medicine
引用
下载
收藏
页码:1170 / 1183
页数:14
相关论文
共 50 条
  • [1] Motion-Compensated Fully 4D PET Reconstruction using PET Data Supersets
    Verhaeghe, J.
    Gravel, P.
    Mio, R.
    Fukasawa, R.
    Rosa-Neto, P.
    Soucy, J. -P.
    Thompson, C. J.
    Reader, A. J.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3000 - +
  • [2] Fully 4D motion-compensated reconstruction of cardiac SPECT images
    Gravier, Erwan
    Yang, Yongyi
    King, Michael A.
    Jin, Mingwu
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (18): : 4603 - 4619
  • [3] Motion-compensated fully 4D reconstruction of gated cardiac sequences
    Gravier, E
    Yang, YY
    COMPUTATIONAL IMAGING III, 2005, 5674 : 305 - 315
  • [4] Motion-Compensated Free-Breathing 3D MRI for MR Simulation Using Rotating Stack-Of-Stars Acquisition
    Zhou, Z.
    Han, F.
    Gao, Y.
    Cao, M.
    Steinberg, M.
    Lee, P.
    Raldow, A.
    Low, D.
    Yang, Y.
    Hu, P.
    MEDICAL PHYSICS, 2017, 44 (06) : 3049 - 3049
  • [5] Auto-labeling of respiratory time points in free-breathing thoracic dynamic MR image acquisitions for 4D image construction
    Sun, Changjian
    Udupa, Jayaram K.
    Tong, Yubing
    Wu, Caiyun
    Guo, Shuxu
    McDonough, Joseph M.
    Torigian, Drew A.
    Campbell, Robert M.
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [6] Motion compensated reconstruction from free breathing 2D radial cardiac MRI data
    André Fischer
    Anne Menini
    Aurelien Bustin
    Kevin M Johnson
    Christopher J Francois
    Anja C Brau
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [7] Sliding motion compensated low-rank plus sparse (SMC-LS) reconstruction for high spatiotemporal free-breathing liver 4D DCE-MRI
    Qiu, Wenyuan
    Li, Dongxiao
    Jin, Xinyu
    Liu, Fan
    Nguyen, Thanh D.
    Prince, Martin R.
    Wang, Yi
    Spincemaille, Pascal
    MAGNETIC RESONANCE IMAGING, 2019, 58 : 56 - 66
  • [8] High quality 4D cone-beam CT reconstruction using motion-compensated total variation regularization
    Zhang, Hua
    Ma, Jianhua
    Bian, Zhaoying
    Zeng, Dong
    Feng, Qianjin
    Chen, Wufan
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (08): : 3313 - 3329
  • [9] Analysis of free breathing motion using artifact reduced 4D CT image data
    Ehrhardt, Jan
    Werner, Rene
    Frenzel, Thorsten
    Lu, Wei
    Low, Daniel
    Handels, Heinz
    MEDICAL IMAGING 2007: IMAGE PROCESSING, PTS 1-3, 2007, 6512
  • [10] Motion artifact reducing reconstruction of 4D CT image data for the analysis of respiratory dynamics
    Werner, R.
    Ehrhardt, J.
    Frenzel, T.
    Saering, D.
    Lu, W.
    Low, D.
    Handels, H.
    METHODS OF INFORMATION IN MEDICINE, 2007, 46 (03) : 254 - 260