Design Charts for Combined Chilled Ceiling Displacement Ventilation System

被引:0
|
作者
Ghaddar, Nesreen [1 ,2 ]
Ghali, Kamel [3 ]
Saadeh, Ralph [1 ]
Keblawi, Amer [1 ]
机构
[1] Amer Univ Beirut, Dept Mech Engn, Beirut, Lebanon
[2] Amer Univ Beirut, Dept Mech Engn, Beirut, Lebanon
[3] Beirut Arab Univ, Beirut, Lebanon
来源
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper proposes operational design charts for combined chilled ceiling (CC) displacement ventilation (DV) hybrid air conditioning system (CC/DV). The design charts were developed by performing a large number of simulations using a simplified transport plume multi-layer model of the CC/DV conditioned space. The simulation model results were validated by conducting a series of experiments that showed good agreement with the predictions of the simplified model of the stratification height, the CC load, and the room air vertical temperature gradient. The proposed design charts, like any chart in the literature, are based on the important parameter of the ratio of the CC cooling load to the total load (R), the thermal comfort represented by the temperature gradient (dT/dZ), and the amount of displaced air parameter (P = (Q/<(m)over dot>)). The design chart parameters include the temperature ranges of the supply air temperature and the chilled ceiling for any R in the feasible design regions where dT/dZ is less than 2.5 K/m and with the facility to read of the stratification height H and insure that it is above 1.2 m. The stratification height was selected as an additional criterion to the thermal comfort because in humid warm climates, designing the CC/DV system for a high stratification height might be quite costly. The CC/DV design charts have shown that R can be met by different P = (Q/<(m)over dot>) for different air supply temperature and chilled ceiling temperatures and that the stratification height is strongly correlated to P = (Q/<(m)over dot>) compared to air and ceiling temperatures. Two correlations were developed at high predictability for the stratification height and vertical temperature gradient dependence on room height and system operational parameters.
引用
下载
收藏
页码:574 / +
页数:2
相关论文
共 50 条
  • [21] Energy Saving Using Mixed Air in Rooms Conditioned by Chilled Ceiling Displacement Ventilation System
    Chakroun, W.
    Ghali, K.
    Ghaddar, N.
    ASHRAE TRANSACTIONS 2011, VOL 117, PT 2, 2011, 117 : 67 - 75
  • [22] Assessment age of air and thermal comfort in a classroom by adopting displacement ventilation with chilled ceiling system
    Shbeeb, Ali Aedan
    Mahdi, Ala'a Abbas
    Hussein, Ahmed Kadhim
    JOURNAL OF ENGINEERING RESEARCH, 2021, 9
  • [23] A critical review on the performance and design of combined cooled ceiling and displacement ventilation systems
    Novoselac, A
    Srebric, J
    ENERGY AND BUILDINGS, 2002, 34 (05) : 497 - 509
  • [24] An Energy Efficient Air Conditioning System using Displacement Ventilation and Chilled Ceiling for Modern Office Buildings
    Parameshwaran, R.
    Karunakaran, R.
    Muthumariappan, S.
    Bipasha, S.
    INTERNATIONAL JOURNAL OF VENTILATION, 2010, 9 (01) : 25 - 44
  • [25] A two-step approach to solve the issue of dew condensation for displacement ventilation and chilled ceiling system
    Tian, Yuchen
    Guo, Shaopeng
    Jin, Guang
    Pang, Yunji
    Wang, Xiaotong
    Wu, Wenfei
    Zhao, Jun
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 6527 - 6531
  • [26] NUMERICAL STUDY ON THERMAL INDOOR ENVIRONMENT OF AN OFFICE WITH HYBRID SYSTEM OF CHILLED CEILING PANEL AND DISPLACEMENT VENTILATION
    Zhao, Lei
    Feng, Yannan
    Yuan, Feng
    Zhang, Peidong
    ACRA 2009: PROCEEDINGS OF THE 4TH ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, 2009, : 547 - 552
  • [27] Investigation of Thermal Comfort in a Space Conditioned by Liquid Desiccant Membrane Chilled Ceiling/Displacement Ventilation System
    Seblany, Racha
    Ghaddar, Nesreen
    Ghali, Kamel
    Ismail, Nagham
    Simonetti, Marco
    Vincenzo, Fracastoro Giovanni
    Virgone, Joseph
    Zoughaib, Assaad
    THIRD INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN - MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2018, : 85 - 94
  • [28] Experimental evaluation of a solar thermoelectric cooled ceiling combined with displacement ventilation system
    Liu, ZhongBing
    Zhang, Ling
    Gong, GuangCai
    ENERGY CONVERSION AND MANAGEMENT, 2014, 87 : 559 - 565
  • [29] Application and Analysis Chilling Ceiling Combined with Displacement Ventilation System in Office Buildings
    Wang Ling
    Qi Weiyang
    Liu Richao
    He Shunjun
    MATERIALS SCIENCE AND ENGINEERING APPLICATIONS, PTS 1-3, 2011, 160-162 : 294 - 300