Assessment age of air and thermal comfort in a classroom by adopting displacement ventilation with chilled ceiling system

被引:0
|
作者
Shbeeb, Ali Aedan [1 ]
Mahdi, Ala'a Abbas [1 ]
Hussein, Ahmed Kadhim [1 ]
机构
[1] Univ Babylon, Coll Engn, Babylon, Iraq
来源
关键词
chilled ceiling; age of air; displacement ventilation; air-exchange efficiency; CFD; QUALITY;
D O I
10.36909/jer.v9iICRIE.11679
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study aims to investigate the effect of the cooling load ratio covered by the chilled ceiling on the age of air and comfort level in a classroom in a hot and dry climate in Iraq-Hilla city. Air age, air exchange efficiency, and concentrations of pollutants in a classroom are investigated numerically by used AIRPAK software under displacement ventilation combined with a chilled ceiling system. Four cases are studied at different values of the cooling load covered by the chilled ceiling (0%, 25%, 50%, 80%) with respect to total classroom cooling load. Cooling load removes by chilled ceiling varied from (0 to 84.5 W/m(2)) based on the classroom area, and its temperature varied between (17.5-22.5 degrees C). The displacement ventilation airflow rate was kept at 0.3m(3)/s, and the air temperature supply varied between (19.5-24.5 degrees C) depend on the amount of cooling load covered by displacement ventilation. The results showed that the mean local air age increasing with height. The room mean air age increase and air exchange efficiency reduce with increasing load portion, which treated by the chilled ceiling. Increasing the portion of the load treated by chilled ceiling tends to improve comfort levels.
引用
下载
收藏
页数:15
相关论文
共 50 条
  • [1] Combining chilled ceiling, displacement ventilation and desiccant dehumidification for indoor air quality and thermal comfort
    Hao, XL
    Zhang, GQ
    Chen, YM
    Zou, SH
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1248 - 1253
  • [2] Investigation of Thermal Comfort in a Space Conditioned by Liquid Desiccant Membrane Chilled Ceiling/Displacement Ventilation System
    Seblany, Racha
    Ghaddar, Nesreen
    Ghali, Kamel
    Ismail, Nagham
    Simonetti, Marco
    Vincenzo, Fracastoro Giovanni
    Virgone, Joseph
    Zoughaib, Assaad
    THIRD INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN - MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2018, : 85 - 94
  • [3] Thermal comfort in chilled ceiling and displacement ventilation environments: Vertical radiant temperature asymmetry effects
    Hodder, SG
    Loveday, DL
    Parsons, KC
    Taki, AH
    ENERGY AND BUILDINGS, 1998, 27 (02) : 167 - 173
  • [4] Evaporative cooler improves transient thermal comfort in chilled ceiling displacement ventilation conditioned space
    Ghaddar, Nesreen
    Ghali, Kamel
    Chakroun, Walid
    ENERGY AND BUILDINGS, 2013, 61 : 51 - 60
  • [5] Indoor thermal environment in rooms with combined air conditioning system of displacement ventilation and chilled ceiling panel
    School of Muni. and Eviron. Eng., Xi'an Univ. of Arch. and Tech, Xi'an 710055, China
    Xi'an Jianzhu Keji Daxue Xuebao, 2007, 4 (558-562):
  • [6] NUMERICAL INVESTIGATION OF OFFICE ROOM VENTILATION BY ADOPTING DISPLACEMENT VENTILATION AND CHILLED CEILING SYSTEM IN A HOT AND DRY CLIMATE
    Shbeeb, Ali A.
    Mahdi, Ala'a A.
    Hussein, Ahmed K.
    JOURNAL OF ENGINEERING SCIENCE AND TECHNOLOGY, 2022, 17 (04): : 2958 - 2982
  • [7] Numerical Comparison of Thermal Comfort and Air Age Between Two Combined Ventilation Systems with Chilled Ceiling Considering Occupant Density
    Nayyef, Dhuha Radhi
    Mahdi, Ala'a Abbas
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2023, 41 (01) : 213 - 223
  • [8] Ceiling displacement ventilation system in an experimental theatre: A method to optimize thermal comfort
    Wan, Fujing
    Liu, Sujie
    Zhang, Huan
    Zheng, Wandong
    INDOOR AND BUILT ENVIRONMENT, 2023, 32 (03) : 521 - 541
  • [9] Room air stratification in combined chilled ceiling and displacement ventilation systems
    Schiavon, Stefano
    Bauman, Fred
    Tully, Brad
    Rimmer, Julian
    HVAC&R RESEARCH, 2012, 18 (1-2): : 147 - 159
  • [10] A combined system of chilled ceiling, displacement ventilation and desiccant dehumidification
    Hao, Xiaoli
    Zhang, Guoqiang
    Chen, Youming
    Zou, Shenghua
    Moschandreas, Demetrios. J.
    BUILDING AND ENVIRONMENT, 2007, 42 (09) : 3298 - 3308