Assessment age of air and thermal comfort in a classroom by adopting displacement ventilation with chilled ceiling system

被引:0
|
作者
Shbeeb, Ali Aedan [1 ]
Mahdi, Ala'a Abbas [1 ]
Hussein, Ahmed Kadhim [1 ]
机构
[1] Univ Babylon, Coll Engn, Babylon, Iraq
来源
关键词
chilled ceiling; age of air; displacement ventilation; air-exchange efficiency; CFD; QUALITY;
D O I
10.36909/jer.v9iICRIE.11679
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This study aims to investigate the effect of the cooling load ratio covered by the chilled ceiling on the age of air and comfort level in a classroom in a hot and dry climate in Iraq-Hilla city. Air age, air exchange efficiency, and concentrations of pollutants in a classroom are investigated numerically by used AIRPAK software under displacement ventilation combined with a chilled ceiling system. Four cases are studied at different values of the cooling load covered by the chilled ceiling (0%, 25%, 50%, 80%) with respect to total classroom cooling load. Cooling load removes by chilled ceiling varied from (0 to 84.5 W/m(2)) based on the classroom area, and its temperature varied between (17.5-22.5 degrees C). The displacement ventilation airflow rate was kept at 0.3m(3)/s, and the air temperature supply varied between (19.5-24.5 degrees C) depend on the amount of cooling load covered by displacement ventilation. The results showed that the mean local air age increasing with height. The room mean air age increase and air exchange efficiency reduce with increasing load portion, which treated by the chilled ceiling. Increasing the portion of the load treated by chilled ceiling tends to improve comfort levels.
引用
下载
收藏
页数:15
相关论文
共 50 条
  • [31] Optimized Operation of Combined Chilled Ceiling Displacement Ventilation System Using Genetic Algorithm
    Mossolly, Mounir
    Ghaddar, Nesreen
    Ghali, Kamel
    Jensen, Lars
    ASHRAE TRANSACTIONS 2008, VOL 114, PT 2, 2008, 114 : 541 - +
  • [32] Investigating the Performance of Ceiling Mounted Personalized Ventilation System Assisted by Chair Fans: Assessment of Thermal Comfort and Indoor Air Quality
    El Fil, Bachir
    Ghaddar, Nesreen
    Ghali, Kamel
    SECOND INTERNATIONAL CONFERENCE ON EFFICIENT BUILDING DESIGN: MATERIALS AND HVAC EQUIPMENT TECHNOLOGIES, 2016, : 138 - 145
  • [33] Thermal comfort study on vertical air temperature gradient with displacement ventilation system in the tropics
    Cheong, KWD
    Yu, WJ
    Sekhar, SC
    Tham, KW
    Kosonen, R
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 249 - 253
  • [34] Influence of the ventilation system on thermal comfort of the chilled panel system in heating mode
    Tian, Zhe
    Ding, Yan
    Wang, Shuo
    Yin, Xinglei
    Wang, Menglei
    ENERGY AND BUILDINGS, 2010, 42 (12) : 2360 - 2364
  • [35] Performance Comparison of Conventional and Chilled Ceiling/Displacement Ventilation Systems in Kuwait
    Bahman, Ammar
    Saade, Ralph
    Chakroun, Walid
    Ghali, Kamel
    Ghaddar, Nesreen
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 1, 2009, 115 : 587 - +
  • [36] A nodal model for displacement ventilation and chilled ceiling systems in office spaces
    Rees, SJ
    Haves, P
    BUILDING AND ENVIRONMENT, 2001, 36 (06) : 753 - 762
  • [37] Simplified Model of Contaminant Dispersion in Rooms Conditioned by Chilled-Ceiling Displacement Ventilation System
    Kanaan, M.
    Ghaddar, N.
    Ghali, K.
    HVAC&R RESEARCH, 2010, 16 (06): : 765 - 783
  • [38] Optimized Strategy for Combined Liquid Desiccant Dehumidification Membrane with Chilled Ceiling and Displacement Ventilation System
    Muslmani, Mohamad
    Ghaddar, Nesreen
    Ghali, Kamel
    6TH INTERNATIONAL CONFERENCE ON ENERGY RESEARCH AND DEVELOPMENT, 2016, : 25 - 32
  • [39] Optimizing performance of ceiling-mounted personalized ventilation system assisted by chair fans: Assessment of thermal comfort and indoor air quality
    El-Fil, Bachir
    Ghaddar, Nesreen
    Ghali, Kamel
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (04) : 412 - 430
  • [40] Study on Thermal Comfort and Indoor Air Quality in the Classroom with System Air-conditioner and Ventilation System for Cooling Loads
    Noh, Kwang-Chul
    Jang, Jae-Soo
    Oh, Myung-Do
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2006, 30 (01) : 57 - 66