Dosimetric accuracy of the ITP™ inverse treatment planning system

被引:8
|
作者
Olch, AJ [1 ]
机构
[1] Childrens Hosp Los Angeles, Radiat Oncol Program, Los Angeles, CA 90027 USA
关键词
Intensity Modulated Radiation Therapy; inverse treatment planning; dosimetry;
D O I
10.1118/1.1513162
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The dosimetric accuracy of the ITP(TM) system for intensity modulated radiation therapy was determined for 19 patient plans. Treatments were given with a Varian 2100C and a 120-leaf multileaf collimator using step and shoot delivery. Both absolute dose, determined by an ionization chamber, and relative dose, determined by film, were assessed. It was found that absolute dose agreement was within 0.1% +/- 1.5%, isodoses in the high dose-low gradient region were within 1.7% +/- 2%, and the distance to agreement for isodoses between 20% and 90% was 1.4 mm +/- 1mm. This agreement is at least as good as that found for standard wedged fields in most treatment planning systems. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:2484 / 2488
页数:5
相关论文
共 50 条
  • [1] Dosimetric verification of a clinical inverse treatment planning system
    Xing, L
    Findley, D
    Ma, L
    Ma, CM
    Forster, K
    Boyer, AL
    [J]. RADIOLOGY, 1998, 209P : 397 - 397
  • [2] Dosimetric verification of a commercial inverse treatment planning system
    Lei, X
    Curran, B
    Hill, R
    Holmes, T
    Ma, LJ
    Forster, KM
    Boyer, AL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (02): : 463 - 478
  • [3] Dosimetric evaluation of a commercial inverse treatment planning system: UAB experience
    Duan, J
    Brezovich, IA
    Pareek, PN
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 1162 - 1164
  • [4] Dosimetric effects of a repositioning head frame system and treatment planning system dose calculation accuracy
    Ferrer, Carlos
    Huertas, Concepcion
    Plaza, Rodrigo
    Aza, Zulima
    Corredoira, Eva
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (06): : 124 - 132
  • [5] RadCalc for Independent Dosimetric Validation of Plans Generated in Accuracy Precision Treatment Planning System
    Romaguera, T.
    Alvarez, D.
    George, S.
    Mishra, V.
    Gutierrez, A.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E310 - E310
  • [6] An Update On the Dosimetric Accuracy of Different Treatment Planning System Algorithms in the IROC Lung Phantom
    Kry, S.
    Molineu, A.
    Alvarez, P.
    Followill, D.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3293 - 3293
  • [7] EVALUATION OF THE DOSIMETRIC ACCURACY OF COUCH MODELING FOR RADIOTHERAPY TREATMENT PLANNING
    Tillikainen, L.
    Kauppinen, J.
    Torsti, T.
    Van Esch, A.
    Huyskens, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S408 - S409
  • [8] DOSIMETRIC MEASUREMENTS OF CHARGED-PARTICLE TREATMENT PLANNING ACCURACY
    COLLIER, JM
    CHEN, GTY
    LYMAN, JT
    PITLUCK, S
    [J]. MEDICAL PHYSICS, 1982, 9 (04) : 623 - 623
  • [9] The effect of dose calculation accuracy on inverse treatment planning
    Jeraj, R
    Keall, PJ
    Siebers, JV
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (03): : 391 - 407
  • [10] Dosimetric Accuracy of an HDR Brachytherapy Treatment Planning System for Different Irradiation Lengths with Monte Carlo Simulation
    Acun Bucht, Hediye
    Bozkurt, Ahmet
    Kemikler, Gonul
    [J]. TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (01): : 36 - 44