The effect of dose calculation accuracy on inverse treatment planning

被引:80
|
作者
Jeraj, R [1 ]
Keall, PJ
Siebers, JV
机构
[1] Jozef Stefan Inst, Ljubljana, Slovenia
[2] Univ Wisconsin, Dept Med Phys, Madison, WI USA
[3] Virginia Commonwealth Univ, Virginia Hosp, Coll Med, Dept Radiat Oncol, Richmond, VA USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2002年 / 47卷 / 03期
关键词
D O I
10.1088/0031-9155/47/3/303
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The effect of dose calculation accuracy during inverse treatment planning for intensity modulated radiotherapy (IMRT) was studied in this work. Three dose calculation methods were compared: Monte Carlo, superposition and pencil beam. These algorithms were used to calculate beamlets, which were subsequently used by a simulated annealing algorithm to determine beamlet weights which comprised the optimal solution to the objective function. Three different cases (lung, prostate and head and neck) were investigated and several different objective functions were tested for their effect on inverse treatment planning. It is shown that the use of inaccurate dose calculation introduces two errors in a treatment plan, a systematic error and a convergence error. The systematic error is present because of the inaccuracy of the dose calculation algorithm. The convergence error appears because the optimal intensity distribution for inaccurate beamlets differs from the optimal solution for the accurate beamlets. While the systematic error for superposition was found to be similar to1 % of D-max in the tumour and slightly larger outside, the error for the pencil beam method is typically similar to5 % of D-max and is rather insensitive to the given objectives. On the other hand, the convergence error was found to be very sensitive to the objective function, is only slightly correlated to the systematic error and should be determined for each case individually. Our results suggest that because of the large systematic and convergence errors, inverse treatment planning systems based on pencil beam algorithms alone should be upgraded either to superposition or Monte Carlo based dose calculations.
引用
收藏
页码:391 / 407
页数:17
相关论文
共 50 条
  • [1] Effect of Incomplete or Incorrect Beam Data On Treatment Planning Dose Calculation Accuracy
    Benson, C.
    Alaei, P.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E558 - E558
  • [2] The effect of statistical uncertainty on inverse treatment planning based on Monte Carlo dose calculation
    Jeraj, R
    Keall, P
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (12): : 3601 - 3613
  • [3] Errors in inverse treatment planning based on inaccurate dose calculation
    Jeraj, R
    Keall, P
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 548 - 550
  • [4] A FILTERED BACKPROJECTION DOSE CALCULATION METHOD FOR INVERSE TREATMENT PLANNING
    HOLMES, T
    MACKIE, TR
    [J]. MEDICAL PHYSICS, 1994, 21 (02) : 303 - 313
  • [5] Investigation of Dose Calculation Accuracy in VMAT Planning for SBRT Lung Treatment
    Rao, M.
    Wu, J.
    Cao, D.
    Ye, J.
    Chen, F.
    Wong, T.
    Mehta, V.
    Shepard, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S774 - S774
  • [6] Evaluation of Treatment Planning Dose Calculation Accuracy at the Interface of Prosthetic Devices
    Paulu, D.
    Alaei, P.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3823 - 3823
  • [7] The influence of dose matrix and voxel dimensions for the dose calculation on inverse treatment planning for stereotactic radiosurgery
    Platoni, K
    Lefkopoulos, D
    Grandjean, P
    Keraudy, K
    [J]. USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 57 - 59
  • [8] Accuracy evaluation of dose calculation of ISOgray treatment planning system in wedged treatment fields
    Raghavi, S.
    Sadoughi, H. R.
    Ravari, M. E.
    Mansoury, M. A. Tajik
    Behmadi, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2020, 22 (02): : 303 - 308
  • [9] Experimental evaluation of the accuracy of skin dose calculation for a commercial treatment planning system
    Court, Laurence E.
    Tishler, Roy B.
    Allen, Aaron M.
    Xiang, Hong
    Makrigiorgos, Mike
    Chin, Lee
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2008, 9 (01): : 29 - 35
  • [10] Accuracy of Dose Calculation Algorithms in MultiPlan Treatment Planning System in Presence of Heterogeneities
    Moignier, C.
    Huet, C.
    Barraux, V.
    Loiseau, C.
    Sebe-Mercier, K.
    Batalla, A.
    Makovicka, L.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 372 - 372