Improved donor safety in high-volume apheresis collections

被引:5
|
作者
Vassallo, Ralph R. [1 ]
Bravo, Marjorie D. [1 ]
Kamel, Hany [1 ]
机构
[1] Blood Syst Inc, 6210 E Oak St, Scottsdale, AZ 85268 USA
关键词
BLOOD-VOLUME; PREDICTION;
D O I
10.1111/trf.13897
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Separators use 1960s sex-based nomograms to estimate apheresis donor blood volume and to calculate the 15% maximum extracorporeal and collection volumes. As US body habitus changes, proportional overestimation of the maximum safe collection volume may become clinically significant with large-volume collections. We correlated 2 years of vasovagal reaction (VVR) data with 148,416 Trima apheresis procedure parameters to identify trends. STUDY DESIGN AND METHODS: Only platelet/plasma with or without red blood cell (RBC) procedures yielded collection volumes of at least 900 mL with no saline replacement. Vasovagal events of any severity were correlated by sex with actual collection volume and donor estimated blood volume (EBV). We performed multivariable analysis incorporating the factors that influence VVR rates to assess the significance of EBV and collection volume. RESULTS: VVR rates nearly doubled in male donors who had collection volumes greater than 1050 mL. No reaction threshold could be identified in female donors. This was confirmed in multivariable analysis that included donor sex, age, donation experience, draw time, and reporting location. CONCLUSION: Limiting apheresis collections to the lesser of 1050 mL or 15% EBV may reduce VVR rates. Further confirmation of this finding by other collection centers is desirable.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 50 条
  • [41] HIGH-VOLUME MANUFACTURING FOR COMPOSITES
    不详
    MATERIALS WORLD, 1993, 1 (11) : 606 - 606
  • [42] High-volume haemofiltration for sepsis
    Borthwick, Emma M. J.
    Hill, Christopher J.
    Rabindranath, Kannaiyan S.
    Maxwell, Alexander P.
    McAuley, Danny F.
    Blackwood, Bronagh
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2013, (01):
  • [43] Improved survival for extremity soft tissue sarcoma treated in high-volume facilities
    Abarca, Tyler
    Gao, Yubo
    Monga, Varun
    Tanas, Munir R.
    Milhem, Mohammed M.
    Miller, Benjamin J.
    JOURNAL OF SURGICAL ONCOLOGY, 2018, 117 (07) : 1479 - 1486
  • [44] Development of high-volume fly ash concrete with improved interfacial transition zone
    Xiao, Tianyu
    Liang, Xiangzhou
    Du, Sen
    JOURNAL OF BUILDING ENGINEERING, 2024, 87
  • [45] ACADEMIC AND HIGH-VOLUME HOSPITALS ARE ASSOCIATED WITH IMPROVED OUTCOMES IN THE MANAGEMENT OF RETROPERITONEAL SARCOMA
    Yih, Jessica
    Maurice, Matthew
    Abouassaly, Robert
    Ammori, John
    JOURNAL OF UROLOGY, 2017, 197 (04): : E931 - E932
  • [46] DEVELOPMENT OF AN IMPROVED HIGH-VOLUME SAMPLING ARRANGEMENT FOR THE TSI AERODYNAMIC PARTICLE SIZER
    BALL, MHE
    MITCHELL, JP
    JOURNAL OF AEROSOL SCIENCE, 1990, 21 : S649 - S652
  • [47] Improved outcome in patients with soft tissue sarcoma treated at high-volume centers
    Nature Clinical Practice Oncology, 2007, 4 (9): : 504 - 505
  • [48] SAFETY OF HIGH-VOLUME PLASMA EXCHANGE IN PEDIATRIC PATIENTS WITH ACUTE LIVER FAILURE
    Walker, Amanda
    Slowik, Joella
    Smith, Kevin
    Levenbrown, Yosef
    CRITICAL CARE MEDICINE, 2024, 52
  • [49] High-volume carburizing technology
    Whitbeck, RG
    Cabadas, EJ
    Lucas, RS
    Mack, CM
    Turner, FG
    Herring, DH
    Greene, JM
    ADVANCED MATERIALS & PROCESSES, 1999, 155 (04): : H21 - H26
  • [50] HIGH-VOLUME LEARNS TO FLEX
    MASON, F
    MANUFACTURING ENGINEERING, 1995, 114 (04): : 53 - &