Improved donor safety in high-volume apheresis collections

被引:5
|
作者
Vassallo, Ralph R. [1 ]
Bravo, Marjorie D. [1 ]
Kamel, Hany [1 ]
机构
[1] Blood Syst Inc, 6210 E Oak St, Scottsdale, AZ 85268 USA
关键词
BLOOD-VOLUME; PREDICTION;
D O I
10.1111/trf.13897
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Separators use 1960s sex-based nomograms to estimate apheresis donor blood volume and to calculate the 15% maximum extracorporeal and collection volumes. As US body habitus changes, proportional overestimation of the maximum safe collection volume may become clinically significant with large-volume collections. We correlated 2 years of vasovagal reaction (VVR) data with 148,416 Trima apheresis procedure parameters to identify trends. STUDY DESIGN AND METHODS: Only platelet/plasma with or without red blood cell (RBC) procedures yielded collection volumes of at least 900 mL with no saline replacement. Vasovagal events of any severity were correlated by sex with actual collection volume and donor estimated blood volume (EBV). We performed multivariable analysis incorporating the factors that influence VVR rates to assess the significance of EBV and collection volume. RESULTS: VVR rates nearly doubled in male donors who had collection volumes greater than 1050 mL. No reaction threshold could be identified in female donors. This was confirmed in multivariable analysis that included donor sex, age, donation experience, draw time, and reporting location. CONCLUSION: Limiting apheresis collections to the lesser of 1050 mL or 15% EBV may reduce VVR rates. Further confirmation of this finding by other collection centers is desirable.
引用
收藏
页码:319 / 324
页数:6
相关论文
共 50 条
  • [31] Pioneering the Perinatal Safety Nurse Role at a High-Volume, High-Acuity Hospital
    Rodriguez, Ciaranais
    Hernandez, Jacqueline
    Greenfield, Lindsay
    Lewandowski, Julianna
    JOGNN-JOURNAL OF OBSTETRIC GYNECOLOGIC AND NEONATAL NURSING, 2024, 53 (04): : S58 - S58
  • [32] Disparities in Access to High-Volume Surgeons Within High-Volume Hospitals for Hysterectomy Reply
    Knisely, Anne
    Wright, Jason D.
    OBSTETRICS AND GYNECOLOGY, 2021, 138 (05): : 820 - 820
  • [33] RELIABILITY OF HIGH-VOLUME PRODUCTS
    HALE, PW
    CME-CHARTERED MECHANICAL ENGINEER, 1987, 34 (11): : 42 - 43
  • [34] CULTIVATE HIGH-VOLUME CONSUMER
    BARKER, SM
    TROST, JF
    HARVARD BUSINESS REVIEW, 1973, 51 (02) : 118 - 122
  • [35] HIGH-VOLUME URETHANE APPLICATION
    SCHRANTZ, J
    INDUSTRIAL FINISHING, 1979, 55 (01): : 18 - 21
  • [36] Implementation of Robotic Approach for Living Donor Nephrectomy in a High-Volume Laparoscopic Centre.
    Papadakis, G.
    Kostakis, I. D.
    Kumar, A.
    Kotecha, P.
    Gogalniceanu, P.
    Mamode, N.
    Olsburgh, J.
    Challacombe, B.
    Kessaris, N.
    Loukopoulos, I.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2022, 22 : 799 - 799
  • [38] High-volume photovoltaic plant
    Ashley, S
    MECHANICAL ENGINEERING, 1996, 118 (04) : 12 - 12
  • [39] THE HIGH-VOLUME PRINTER OPTION
    FOLEY, MJ
    DATAMATION, 1989, 35 (20): : 59 - 60
  • [40] THE USE OF HIGH-VOLUME TESTING INSTRUMENTATION TO SELECT FIBERS FOR IMPROVED YARN QUALITY
    LLOYD, SA
    ROGERS, CD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1986, 191 : 14 - CELL