Measurement of axial dispersion coefficient in a packed bed using X-ray

被引:3
|
作者
Basavaraj, MG [1 ]
Gupta, GS [1 ]
机构
[1] Indian Inst Sci, Dept Met, Bangalore 560012, Karnataka, India
关键词
dispersion; porous media; x-ray absorption; imaging; concentration;
D O I
10.1081/AMP-120016091
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Dispersion of the liquid in a porous media is of great importance in many areas of engineering and has been studied by several researchers so far. A new experimental method has been developed to measure the dispersion coefficient. X-ray absorption technique provides a better understanding of dispersion that characterizes the mixing phenomenon in the packed beds. This is because the method is non-invasive and also it gives tracer concentration data at every point within the bed. The axial dispersion in a cylindrical bed of non-porous and non-wetting spherical particles has been measured for the flow of water. Aqueous barium chloride solution has been used a as tracer. X-ray images, recorded on a videocassette, have been analyzed using an image processing software to extract the local interstitial velocity and concentration data in the bed. Local dispersion coefficient has been determined with the help of aforementioned data. By using these data, the overall dispersion coefficient in a packed bed can also be estimated.
引用
收藏
页码:683 / 692
页数:10
相关论文
共 50 条
  • [41] New calibration technique for X-ray absorption studies in single and multiphase flows in packed bed
    Basavaraj, MG
    Gupta, GS
    ISIJ INTERNATIONAL, 2004, 44 (01) : 50 - 58
  • [42] X-ray computed tomography for the representation of chromatographic structure at the individual bead and packed bed scales
    Johnson, Thomas
    Shearing, Paul
    Peter, Levison
    Bracewell, Daniel
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [43] X-ray computed tomography of packed bed chromatography columns for three dimensional imaging and analysis
    Johnson, T. F.
    Levison, P. R.
    Shearing, P. R.
    Bracewella, D. G.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1487 : 108 - 115
  • [44] X-RAY MICROSCOPY USING COMPUTERIZED AXIAL-TOMOGRAPHY
    ELLIOTT, JC
    DOVER, SD
    JOURNAL OF MICROSCOPY-OXFORD, 1985, 138 (JUN): : 329 - 331
  • [45] Effect of X-ray μCT Resolution on the Computation of Permeability and Dispersion Coefficient for Granular Soils
    Ortega-Ramirez, Miriam Patricia
    Oxarango, Laurent
    TRANSPORT IN POROUS MEDIA, 2021, 137 (02) : 307 - 326
  • [46] Measurement of X-ray beam emittance using crystal optics at an X-ray undulator beamline
    Kohmura, Y
    Suzuki, Y
    Awaji, M
    Tanaka, T
    Hara, T
    Goto, S
    Ishikawa, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 452 (1-2): : 343 - 350
  • [47] Erratum: Determination of total x-ray absorption coefficient using non-resonant x-ray emission
    A. J. Achkar
    T. Z. Regier
    E. J. Monkman
    K. M. Shen
    D. G. Hawthorn
    Scientific Reports, 3
  • [48] In-situ Measurement of Solute Partition Coefficient in Fe-Cr-Ni-Mo Alloys by Using X-ray Imaging and X-ray Florescence Analysis
    Uwabe, Iori
    Dobara, Kento
    Morishita, Kohei
    Nagira, Tomoya
    Yasuda, Hideyuki
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 2017, 103 (12): : 12 - 21
  • [49] X-ray tube with axial focusing
    Kuznetsov V.L.
    Skomorokhov D.S.
    Filatov A.L.
    Bulletin of the Russian Academy of Sciences: Physics, 2008, 72 (4) : 489 - 491
  • [50] Semiconductor interface studies using X-ray anomalous dispersion
    Poverkhnost Fiz Khim Mekh, 3-4 (242-249):