Measurement of axial dispersion coefficient in a packed bed using X-ray

被引:3
|
作者
Basavaraj, MG [1 ]
Gupta, GS [1 ]
机构
[1] Indian Inst Sci, Dept Met, Bangalore 560012, Karnataka, India
关键词
dispersion; porous media; x-ray absorption; imaging; concentration;
D O I
10.1081/AMP-120016091
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Dispersion of the liquid in a porous media is of great importance in many areas of engineering and has been studied by several researchers so far. A new experimental method has been developed to measure the dispersion coefficient. X-ray absorption technique provides a better understanding of dispersion that characterizes the mixing phenomenon in the packed beds. This is because the method is non-invasive and also it gives tracer concentration data at every point within the bed. The axial dispersion in a cylindrical bed of non-porous and non-wetting spherical particles has been measured for the flow of water. Aqueous barium chloride solution has been used a as tracer. X-ray images, recorded on a videocassette, have been analyzed using an image processing software to extract the local interstitial velocity and concentration data in the bed. Local dispersion coefficient has been determined with the help of aforementioned data. By using these data, the overall dispersion coefficient in a packed bed can also be estimated.
引用
收藏
页码:683 / 692
页数:10
相关论文
共 50 条
  • [31] MEASUREMENT OF THE TEMPERATURE-COEFFICIENT OF LINEAR EXPANSION ON AN X-RAY SPECTROMETER
    LISOIVAN, VI
    MEASUREMENT TECHNIQUES USSR, 1986, 29 (10): : 961 - 963
  • [32] MEASUREMENT OF X-RAY QUALITY USING TLD
    BUSHONG, SC
    GRAY, PM
    PRASAD, N
    GLAZE, SA
    HEALTH PHYSICS, 1974, 26 (04): : 358 - 360
  • [33] Determination of total x-ray absorption coefficient using non-resonant x-ray emission
    Achkar, A. J.
    Regier, T. Z.
    Monkman, E. J.
    Shen, K. M.
    Hawthorn, D. G.
    SCIENTIFIC REPORTS, 2011, 1
  • [34] Determination of total x-ray absorption coefficient using non-resonant x-ray emission
    A. J. Achkar
    T. Z. Regier
    E. J. Monkman
    K. M. Shen
    D. G. Hawthorn
    Scientific Reports, 1
  • [35] Measurement of X-ray mass attenuation coefficient of nickel around the K-edge using synchrotron radiation based X-ray absorption study
    Roy, Bunty Rani
    Rajput, Parasmani
    Jha, S. N.
    Rao, A. S. Nageswara
    RADIATION PHYSICS AND CHEMISTRY, 2015, 114 : 38 - 42
  • [36] Near K-edge measurement of the X-ray attenuation coefficient of heavy elements using a tuneable X-ray source based on an electron LINAC
    Materna, T
    Jolie, J
    Mondelaers, W
    Masschaele, B
    RADIATION PHYSICS AND CHEMISTRY, 2000, 59 (5-6) : 449 - 457
  • [37] X-RAY EXTENDED-RANGE TECHNIQUE FOR PRECISION MEASUREMENT OF THE X-RAY MASS ATTENUATION COEFFICIENT AND IM(F) FOR MOLYBDENUM USING SYNCHROTRON RADIATION
    de Jonge, M. D.
    Tran, C. Q.
    Barnea, Z.
    Dhal, B. B.
    Cookson, D. J.
    Chantler, C. T.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2002, 58 : C82 - C82
  • [38] X-ray extended-range technique for precision measurement of the X-ray mass attenuation coefficient and Im(f) for copper using synchrotron radiation
    Chantler, CT
    Tran, CQ
    Paterson, D
    Cookson, D
    Barnea, Z
    PHYSICS LETTERS A, 2001, 286 (05) : 338 - 346
  • [39] AXIAL DISPERSION COEFFICIENT MEASUREMENT IN 2-PHASE FLOW
    GOMEZPLATA, A
    BROWN, RW
    AICHE JOURNAL, 1968, 14 (04) : 657 - +
  • [40] Measurement of liquid holdup and axial dispersion in trickle bed reactors using radiotracer technique
    Pant, HJ
    Saroha, AK
    Nigam, KDP
    NUKLEONIKA, 2000, 45 (04) : 235 - 241