In Vivo Tumor Grading of Prostate Cancer Using Quantitative 111In-Capromab Pendetide SPECT/CT

被引:16
|
作者
Seo, Youngho [1 ,2 ,3 ,4 ]
Aparici, Carina Mari [1 ,5 ]
Cooperberg, Matthew R. [5 ,6 ]
Konety, Badrinath R. [5 ,6 ]
Hawkins, Randall A. [1 ,2 ,3 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Joint Grad Grp Bioengn, San Francisco, CA 94143 USA
[3] Univ Calif Berkeley, Joint Grad Grp Bioengn, Berkeley, CA 94720 USA
[4] Univ Calif San Francisco, Helen Diller Family Comprehens Canc Ctr, Dept Radiat Oncol, San Francisco, CA 94143 USA
[5] San Francisco VA Med Ctr, San Francisco, CA USA
[6] Univ Calif San Francisco, Dept Urol, San Francisco, CA 94143 USA
关键词
prostate cancer; capromab pendetide; SPECT; SPECT/CT; quantification; tracer quantification; quantitative SPECT; prostate-specific membrane antigen (PSMA); MEMBRANE ANTIGEN; ATTENUATION CORRECTION; RADICAL PROSTATECTOMY; FOLLOW-UP; PET; VALIDATION; SIMULATION;
D O I
10.2967/jnumed.109.067108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed an in vivo method to quantify antibody uptake using In-111-capromab pendetide SPECT combined with CT (SPECT/CT). Our goal was to evaluate this method for potential grading of prostate tumors. Methods: Our phantom experiments focused on the robustness of an advanced iterative reconstruction algorithm that involves corrections for photon attenuation, scatter, and geometric blurring caused by radionuclide collimators. The conversion factors between image values and tracer concentrations (in Bq/mL) were calculated from a uniform phantom filled with an aqueous solution of (InCl3)-In-111 using the same acquisition protocol and reconstruction parameters as for patient studies. In addition, the spatial resolution of the reconstructed images was measured from a point source phantom. The measured spatial resolution was modeled into a point-spread function, and the point-spread function was implemented in a deconvolution-based partial-volume-error correction algorithm. The recovery capability to correctly estimate true tracer concentrations was tested using prostatelike and bladderlike lesion phantoms fitted in the modified National Electrical Manufacturers Association/International Electrotechnical Commission body phantom. Patients with biopsy-proven prostate cancer (n = 10) who underwent prostatectomy were prospectively enrolled in the preoperative SPECT/CT studies at the San Francisco Veterans Affairs Medical Center. The CT portion of SPECT/CT was used to generate CT-based attenuation maps and as an anatomic localization tool for clinical interpretation. Pathologic Gleason grades were compared with in vivo antibody uptake value (AUV) normalized by injected dose, effective half-life, and injection-scan time difference. AUVs were calculated in each lobe of the prostate gland with cylindric volumes of interest having dimensions of 1.5 cm in both diameter and height. Results: Reconstructed SPECT images further corrected by the deconvolution-based partial-volume-error correction could recover tracer concentrations up to 90% of true values in measurements of phantom volumes as small as 7.77 mL. From patient studies, there was a statistically significant correlation (rho = 0.71, P = 0.033) between higher AUVs (from either left or right lobe) and higher components of pathologic Gleason scores. Conclusion: Our results strongly indicate potential for noninvasive prostate tumor grading using quantitative In-111-capromab pendetide SPECT/CT.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [1] Direct comparison of 111In-Capromab Pendetide SPECT/CT and MRI in the evaluation of existing and recurrent prostate cancer
    Rieter, William
    Gordon, Leonie
    Hardie, Andrew
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [2] Diagnostic Performance of In-111 Capromab Pendetide SPECT/CT in Localized and Metastatic Prostate Cancer
    Rieter, William J.
    Keane, Thomas E.
    Ahlman, Mark A.
    Ellis, Clayton T.
    Spicer, Kenneth M.
    Gordon, Leonie L.
    CLINICAL NUCLEAR MEDICINE, 2011, 36 (10) : 872 - 878
  • [3] Utilization of 111In-Capromab pendetide SPECT-CT for detecting seminal vesicle invasion with recurrent prostate cancer after primary in situ therapy
    Kimura, Masaki
    Tsivian, Matvey
    Mouraviev, Vladimir
    Mayes, Janice M.
    Price, Marva M.
    Bannister, Michael C.
    Madden, John F.
    Wong, Terence Z.
    Polascik, Thomas J.
    INTERNATIONAL JOURNAL OF UROLOGY, 2009, 16 (12) : 971 - 975
  • [4] Use of 111In-Capromab Pendetide Immunoscintigraphy to Image Localized Prostate Cancer Foci Within the Prostate Gland
    Mouraviev, Vladimir
    Madden, John F.
    Broadwater, Gloria
    Mayes, Janice M.
    Burchette, James L.
    Schneider, Frank
    Smith, Jill
    Tsivian, Matvey
    Wong, Terence
    Polascik, Thomas J.
    JOURNAL OF UROLOGY, 2009, 182 (03): : 938 - 947
  • [5] CORRELATION OF INDIUM-111 CAPROMAB PENDETIDE SPECT/CT TO SOFT TISSUE HISTOPATHOLOGY IN PROSTATE CANCER
    Rieter, William
    Deem, Samuel
    Gordon, Leonie
    Keane, Thomas
    JOURNAL OF UROLOGY, 2011, 185 (04): : E925 - E925
  • [6] Use of 111In-Capromab Pendetide Immunoscintigraphy to Image Localized Prostate Cancer Foci Within the Prostate Gland EDITORIAL COMMENT
    Bander, Neil H.
    JOURNAL OF UROLOGY, 2009, 182 (03): : 947 - 948
  • [7] Use of local 111In-capromab pendetide scan results to predict outcome after salvage radiotherapy for prostate cancer
    Koontz, Bridget F.
    Mouraviev, Vladimir
    Johnson, Jeffrey L.
    Mayes, Janice
    Chen, Stephanie H.
    Wong, Terence Z.
    Anscher, Mitchell S.
    Sun, Leon
    Moul, Judd
    Polascik, Thomas J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (02): : 358 - 361
  • [8] Detection of Recurrent Prostate Carcinoma with anti-1-Amino-3-18F-Fluorocyclobutane-1-Carboxylic Acid PET/CT and 111In-Capromab Pendetide SPECT/CT
    Schuster, David M.
    Savir-Baruch, Bital
    Nieh, Peter T.
    Master, Viraj A.
    Halkar, Raghuveer K.
    Rossi, Peter J.
    Lewis, Melinda M.
    Nye, Jonathon A.
    Yu, Weiping
    Bowman, F. DuBois
    Goodman, Mark M.
    RADIOLOGY, 2011, 259 (03) : 852 - 861
  • [9] 111In-capromab pendetide -: The evolution of prostate specific membrane antigen and the nuclear imaging of its 111In-labelled murine antibody in the evaluation of prostate cancer
    Plut, EM
    Hinkle, GH
    BIODRUGS, 2000, 13 (06) : 437 - 447
  • [10] Prostate cancer treatment guided by capromab pendetide/CT imaging
    Sodee, DB
    Resnick, MI
    Faulhaber, PF
    Maclennan, GT
    Ellis, RJ
    Nelson, AD
    Lee, ZH
    Devlin, A
    Bakale, G
    JOURNAL OF UROLOGY, 2003, 169 (04): : 464 - 465