In Vivo Tumor Grading of Prostate Cancer Using Quantitative 111In-Capromab Pendetide SPECT/CT

被引:16
|
作者
Seo, Youngho [1 ,2 ,3 ,4 ]
Aparici, Carina Mari [1 ,5 ]
Cooperberg, Matthew R. [5 ,6 ]
Konety, Badrinath R. [5 ,6 ]
Hawkins, Randall A. [1 ,2 ,3 ]
机构
[1] Univ Calif San Francisco, Dept Radiol & Biomed Imaging, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Joint Grad Grp Bioengn, San Francisco, CA 94143 USA
[3] Univ Calif Berkeley, Joint Grad Grp Bioengn, Berkeley, CA 94720 USA
[4] Univ Calif San Francisco, Helen Diller Family Comprehens Canc Ctr, Dept Radiat Oncol, San Francisco, CA 94143 USA
[5] San Francisco VA Med Ctr, San Francisco, CA USA
[6] Univ Calif San Francisco, Dept Urol, San Francisco, CA 94143 USA
关键词
prostate cancer; capromab pendetide; SPECT; SPECT/CT; quantification; tracer quantification; quantitative SPECT; prostate-specific membrane antigen (PSMA); MEMBRANE ANTIGEN; ATTENUATION CORRECTION; RADICAL PROSTATECTOMY; FOLLOW-UP; PET; VALIDATION; SIMULATION;
D O I
10.2967/jnumed.109.067108
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We have developed an in vivo method to quantify antibody uptake using In-111-capromab pendetide SPECT combined with CT (SPECT/CT). Our goal was to evaluate this method for potential grading of prostate tumors. Methods: Our phantom experiments focused on the robustness of an advanced iterative reconstruction algorithm that involves corrections for photon attenuation, scatter, and geometric blurring caused by radionuclide collimators. The conversion factors between image values and tracer concentrations (in Bq/mL) were calculated from a uniform phantom filled with an aqueous solution of (InCl3)-In-111 using the same acquisition protocol and reconstruction parameters as for patient studies. In addition, the spatial resolution of the reconstructed images was measured from a point source phantom. The measured spatial resolution was modeled into a point-spread function, and the point-spread function was implemented in a deconvolution-based partial-volume-error correction algorithm. The recovery capability to correctly estimate true tracer concentrations was tested using prostatelike and bladderlike lesion phantoms fitted in the modified National Electrical Manufacturers Association/International Electrotechnical Commission body phantom. Patients with biopsy-proven prostate cancer (n = 10) who underwent prostatectomy were prospectively enrolled in the preoperative SPECT/CT studies at the San Francisco Veterans Affairs Medical Center. The CT portion of SPECT/CT was used to generate CT-based attenuation maps and as an anatomic localization tool for clinical interpretation. Pathologic Gleason grades were compared with in vivo antibody uptake value (AUV) normalized by injected dose, effective half-life, and injection-scan time difference. AUVs were calculated in each lobe of the prostate gland with cylindric volumes of interest having dimensions of 1.5 cm in both diameter and height. Results: Reconstructed SPECT images further corrected by the deconvolution-based partial-volume-error correction could recover tracer concentrations up to 90% of true values in measurements of phantom volumes as small as 7.77 mL. From patient studies, there was a statistically significant correlation (rho = 0.71, P = 0.033) between higher AUVs (from either left or right lobe) and higher components of pathologic Gleason scores. Conclusion: Our results strongly indicate potential for noninvasive prostate tumor grading using quantitative In-111-capromab pendetide SPECT/CT.
引用
收藏
页码:31 / 36
页数:6
相关论文
共 50 条
  • [21] Improved performance of SPECT-CT In-111 capromab pendetide by correlation with diffusion-weighted magnetic resonance imaging for identifying metastatic pelvic lymphadenopathy in prostate cancer
    Andrew D. Hardie
    William J. Rieter
    Marques L. Bradshaw
    Leonie L. Gordon
    Matthew A. Young
    Thomas E. Keane
    World Journal of Urology, 2013, 31 : 1327 - 1332
  • [22] 111Indium-capromab pendetide in the evaluation of patients with residual or recurrent prostate cancer after radical prostatectomy
    Kahn, D
    Williams, RD
    Manyak, MJ
    Haseman, MK
    Seldin, DW
    Libertino, JA
    Maguire, RT
    JOURNAL OF UROLOGY, 1998, 159 (06): : 2041 - 2046
  • [23] Improvement in Dose Escalation to Intraprostatic Lesion Identified with MpMRI Compared to SPECT/CT Capromab Pendetide for Prostate Seed Implantation
    Muenkel, J.
    Ellis, R.
    Traughber, B.
    Ponsky, L.
    Xu, Z.
    Podder, T.
    MEDICAL PHYSICS, 2019, 46 (06) : E577 - E577
  • [24] 111In-Capromab PendetideThe Evolution of Prostate Specific Membrane Antigen and the Nuclear Imaging of its 111In-Labelled Murine Antibody in the Evaluation of Prostate Cancer
    Edward M. Plut
    George H. Hinkle
    BioDrugs, 2000, 13 : 437 - 447
  • [25] Possible false-positive metastatic prostate cancer on an In-111 capromab pendetide scan as a result of a pelvic kidney
    Valliappan, S
    Joyce, JM
    Myers, DT
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (12) : 984 - 985
  • [26] IMAGE-GUIDED RADIOTHERAPY FOR PROSTATE CANCER: A PROSPECTIVE TRIAL OF CONCOMITANT BOOST USING INDIUM-111-CAPROMAB PENDETIDE (PROSTASCINT) IMAGING
    Wong, William W.
    Schild, Steven E.
    Vora, Sujay A.
    Ezzell, Gary A.
    Nguyen, Ba D.
    Ram, Panol C.
    Roarke, Michael C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (04): : E423 - E429
  • [27] 111indium-capromab pendetide in evaluation of patients with residual or recurrent prostate cancer after radical prostatectomy -: Comment
    Seltzer, M
    Naitoh, J
    JOURNAL OF UROLOGY, 1998, 159 (06): : 2046 - 2046
  • [28] Central abdominal uptake of indium-111 capromab pendetide (ProstaScint) predicts for poor prognosis in patients with prostate cancer
    Haseman, Michael K.
    Rosenthal, Seth A.
    Kipper, Samuel L.
    Trout, J. Richard
    Manyak, Michael J.
    UROLOGY, 2007, 70 (02) : 303 - 308
  • [29] Long-term follow-up of 111In-capromab pendetide (ProstaScint) scan as pretreatment assessment in patients who undergo salvage radiotherapy for rising prostate-specific antigen after radical prostatectomy for prostate cancer
    Nagda, Suneel N.
    Morideen, Najeeb
    Lo, Simon S.
    Khan, Usman
    Dillehay, Gary
    Wagner, Robert
    Campbell, Steven
    Flanigan, Robert
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 67 (03): : 834 - 840
  • [30] Radioimmunoscintigraphy with In-111-labeled capromab pendetide predicts prostate cancer response to salvage radiotherapy after failed radical prostatectomy
    Kahn, D
    Williams, RD
    Haseman, MK
    Reed, NL
    Miller, SJ
    Gerstbrein, J
    JOURNAL OF CLINICAL ONCOLOGY, 1998, 16 (01) : 284 - 289