Diagnostic Performance of In-111 Capromab Pendetide SPECT/CT in Localized and Metastatic Prostate Cancer

被引:18
|
作者
Rieter, William J. [3 ]
Keane, Thomas E. [2 ]
Ahlman, Mark A. [1 ]
Ellis, Clayton T. [3 ]
Spicer, Kenneth M. [1 ]
Gordon, Leonie L. [1 ]
机构
[1] Med Univ S Carolina, Dept Radiol, Charleston, SC 29425 USA
[2] Med Univ S Carolina, Dept Urol, Charleston, SC 29425 USA
[3] Med Univ S Carolina, Coll Med, Charleston, SC 29425 USA
关键词
prostate cancer; In-111 capromab pendetide; monoclonal antibody; SPECT/CT; MEMBRANE ANTIGEN-EXPRESSION; SALVAGE RADIOTHERAPY; RADIATION-THERAPY; (111)INDIUM-CAPROMAB PENDETIDE; INDIUM-111-CAPROMAB PENDETIDE; MONOCLONAL-ANTIBODIES; RADICAL PROSTATECTOMY; RADIOIMMUNOSCINTIGRAPHY; PROSTASCINT; PREDICTS;
D O I
10.1097/RLU.0b013e318219ae29
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine the diagnostic performance of In-111 capromab pendetide single photon emission computed tomography/computed tomography (SPECT/CT), in the prostate gland, seminal vesicles, and lymph nodes via correlation to a gold standard of histopathology. Materials and Methods: In this study, we retrospectively reviewed all In-111 capromab pendetide SPECT/CT acquired at our institution for dedicated histopathology within a 4-month period. Statistical measures of performance were calculated in terms of glandular, seminal vesicle, and lymph node activity. The accuracies of glandular and seminal vesicle activity were then correlated to the indices of risk, including the stage, Gleason score, and prostate-specific antigen level, as well as the treatment history. Results: Of the 200 scans meeting the criteria of our study, 197 had prostate gland histopathology, 94 had bilateral seminal vesicle histopathology, and 5 had a total of 43 resected lymph nodes for comparison. The overall accuracies of the scan results were determined to be 77.7% (area under the receiver operating characteristic curve [AUC] = 0.539) for the gland, 67.0% (AUC = 0.510) for the seminal vesicles, and 93.0% (AUC = 0.787) for lymph nodes. For glandular activity alone, scan accuracy was found to significantly improve with increasing Gleason score (P < 0.0001), and in a setting prior to treatment (P < 0.0005). No statistically significant differences were found between different scan groups with regards to seminal vesicle activity. Conclusions: The results of this study provide substantiating evidence In-111 capromab pendetide can be used to accurately diagnose lymph node metastases from primary cancers of the prostate; however, they also suggest the test may have limited utility in diagnosing tumors within the prostate gland and seminal vesicles.
引用
收藏
页码:872 / 878
页数:7
相关论文
共 50 条
  • [1] Improved performance of SPECT-CT In-111 capromab pendetide by correlation with diffusion-weighted magnetic resonance imaging for identifying metastatic pelvic lymphadenopathy in prostate cancer
    Hardie, Andrew D.
    Rieter, William J.
    Bradshaw, Marques L.
    Gordon, Leonie L.
    Young, Matthew A.
    Keane, Thomas E.
    WORLD JOURNAL OF UROLOGY, 2013, 31 (06) : 1327 - 1332
  • [2] Improved performance of SPECT-CT In-111 capromab pendetide by correlation with diffusion-weighted magnetic resonance imaging for identifying metastatic pelvic lymphadenopathy in prostate cancer
    Andrew D. Hardie
    William J. Rieter
    Marques L. Bradshaw
    Leonie L. Gordon
    Matthew A. Young
    Thomas E. Keane
    World Journal of Urology, 2013, 31 : 1327 - 1332
  • [3] In Vivo Tumor Grading of Prostate Cancer Using Quantitative 111In-Capromab Pendetide SPECT/CT
    Seo, Youngho
    Aparici, Carina Mari
    Cooperberg, Matthew R.
    Konety, Badrinath R.
    Hawkins, Randall A.
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (01) : 31 - 36
  • [4] Possible false-positive metastatic prostate cancer on an In-111 capromab pendetide scan as a result of a pelvic kidney
    Valliappan, S
    Joyce, JM
    Myers, DT
    CLINICAL NUCLEAR MEDICINE, 1999, 24 (12) : 984 - 985
  • [5] CORRELATION OF INDIUM-111 CAPROMAB PENDETIDE SPECT/CT TO SOFT TISSUE HISTOPATHOLOGY IN PROSTATE CANCER
    Rieter, William
    Deem, Samuel
    Gordon, Leonie
    Keane, Thomas
    JOURNAL OF UROLOGY, 2011, 185 (04): : E925 - E925
  • [6] Direct comparison of 111In-Capromab Pendetide SPECT/CT and MRI in the evaluation of existing and recurrent prostate cancer
    Rieter, William
    Gordon, Leonie
    Hardie, Andrew
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [7] Use of 111In-Capromab Pendetide Immunoscintigraphy to Image Localized Prostate Cancer Foci Within the Prostate Gland
    Mouraviev, Vladimir
    Madden, John F.
    Broadwater, Gloria
    Mayes, Janice M.
    Burchette, James L.
    Schneider, Frank
    Smith, Jill
    Tsivian, Matvey
    Wong, Terence
    Polascik, Thomas J.
    JOURNAL OF UROLOGY, 2009, 182 (03): : 938 - 947
  • [8] Indium-111 capromab pendetide (ProstaScint) imaging to detect recurrent and metastatic prostate cancer
    Petronis, JD
    Regan, F
    Lin, K
    CLINICAL NUCLEAR MEDICINE, 1998, 23 (10) : 672 - 677
  • [9] Prostate cancer treatment guided by capromab pendetide/CT imaging
    Sodee, DB
    Resnick, MI
    Faulhaber, PF
    Maclennan, GT
    Ellis, RJ
    Nelson, AD
    Lee, ZH
    Devlin, A
    Bakale, G
    JOURNAL OF UROLOGY, 2003, 169 (04): : 464 - 465
  • [10] Indium-111 capromab pendetide in the management of recurrent prostate cancer
    Manyak, Michael J.
    EXPERT REVIEW OF ANTICANCER THERAPY, 2008, 8 (02) : 175 - 181