Acoustic inspection of bond strength of steel-reinforced mortar after exposure to elevated temperatures

被引:18
|
作者
Chiang, CH
Tsai, CL
Kan, YC
机构
[1] Chaoyang Univ Technol, Dept Construct Engn, Taichung 413, Taiwan
[2] Natl Yunlin Univ Sci & Technol, Dept Construct Engn, Touliu 640, Yunlin, Taiwan
关键词
acoustic inspection; bond strength; concrete; steel reinforcement;
D O I
10.1016/S0041-624X(99)00088-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In order to evaluate the bond strength between the reinforcement and concrete after fire damage, a combination of acoustic through-transmission and pull-out tests were used. Previous studies have shown a 25% decrease in the ultrasonic pulse velocity at 90% of the maximum load at room temperature. The specimens were kept in the oven at an elevated temperature for 1, 2, or 3 h. They were then removed and cooled to room temperature. Inspection was conducted using a high-power ultrasonic pulse velocity system while a pull-out load was applied. The correlation between preheated temperature, acoustic wave velocity, and the applied load was analyzed. Initial results show that bond strength and pulse velocity decreased substantially as the temperature or the heating time increased. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:534 / 536
页数:3
相关论文
共 50 条
  • [41] Thermal behavior and mechanical properties of geopolymer mortar after exposure to elevated temperatures
    Zhang, Hai Yan
    Kodur, Venkatesh
    Wu, Bo
    Cao, Liang
    Wang, Fan
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 109 : 17 - 24
  • [42] Mechanical properties and bond strength degradation of GFRP and steel rebars at elevated temperatures
    Ozkal, Fatih Mehmet
    Polat, Mehmet
    Yagan, Mahmud
    Ozturk, Muhammed Orhan
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 184 : 45 - 57
  • [43] Behaviour of stainless steel bolts after exposure to elevated temperatures
    Hu, Ying
    Tang, Sheng-Lin
    George, Adomako Kumi
    Tao, Zhong
    Wang, Xing-Qiang
    Huu-Tai Thai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 157 : 371 - 385
  • [44] Splitting strength of GGBFS concrete incorporating with steel fiber and polypropylene fiber after exposure to elevated temperatures
    Gao, Danying
    Yan, Dongming
    Li, Xiangyu
    FIRE SAFETY JOURNAL, 2012, 54 : 67 - 73
  • [45] Flexural stiffness of RC beams with high-strength steel bars after exposure to elevated temperatures
    Zhao, Jun
    Jiang, Yibo
    Cai, Gaochuang
    Deng, Xiangsheng
    Si Larbi, Amir
    STRUCTURAL CONCRETE, 2024, 25 (05) : 3081 - 3102
  • [46] Experimental study on the bond behavior between steel and reinforced concrete in steel-reinforced concrete beams
    Shao, Yong-Jian
    Yao, Jiang-Feng
    Xi'an Jianzhu Keji Daxue Xuebao/Journal of Xi'an University of Architecture & Technology, 2002, 34 (02):
  • [47] Residual strength of steel fibre reinforced rubberised UHPC under elevated temperatures
    Lyu, Xin
    Elchalakani, Mohamed
    Ahmed, Tanvir
    Sadakkathulla, Mohamed Ali
    Youssf, Osama
    JOURNAL OF BUILDING ENGINEERING, 2023, 76
  • [48] Performance of Steel-Reinforced Concrete Beam-to-Column Joints after Exposure to Fire
    Song, Tian-Yi
    Han, Lin-Hai
    Tao, Zhong
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (10)
  • [49] Residual bond behavior of high strength concrete-filled square steel tube after elevated temperatures
    Chen, Zongping
    Liu, Xiang
    Zhou, Wenxiang
    STEEL AND COMPOSITE STRUCTURES, 2018, 27 (04): : 509 - 523
  • [50] Performance of Steel-Reinforced Concrete Column after Exposure to Fire: FEA Model and Experiments
    Han, Lin-Hai
    Zhou, Kan
    Tan, Qing-Hua
    Song, Tian-Yi
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (09)