Acoustic inspection of bond strength of steel-reinforced mortar after exposure to elevated temperatures

被引:18
|
作者
Chiang, CH
Tsai, CL
Kan, YC
机构
[1] Chaoyang Univ Technol, Dept Construct Engn, Taichung 413, Taiwan
[2] Natl Yunlin Univ Sci & Technol, Dept Construct Engn, Touliu 640, Yunlin, Taiwan
关键词
acoustic inspection; bond strength; concrete; steel reinforcement;
D O I
10.1016/S0041-624X(99)00088-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In order to evaluate the bond strength between the reinforcement and concrete after fire damage, a combination of acoustic through-transmission and pull-out tests were used. Previous studies have shown a 25% decrease in the ultrasonic pulse velocity at 90% of the maximum load at room temperature. The specimens were kept in the oven at an elevated temperature for 1, 2, or 3 h. They were then removed and cooled to room temperature. Inspection was conducted using a high-power ultrasonic pulse velocity system while a pull-out load was applied. The correlation between preheated temperature, acoustic wave velocity, and the applied load was analyzed. Initial results show that bond strength and pulse velocity decreased substantially as the temperature or the heating time increased. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:534 / 536
页数:3
相关论文
共 50 条
  • [21] Compressive behavior of steel-reinforced concrete-filled square steel tubular stub columns after exposure to elevated temperature
    Yang, Xia
    Tang, Chao
    Chen, Yu
    Qiao, Tian-Yang
    ENGINEERING STRUCTURES, 2020, 204 (204)
  • [22] Self-Healing of SMA and Steel-Reinforced Mortar with Microcapsules
    Arce, Gabriel A.
    Hassan, Marwa M.
    Mohammad, Louay N.
    Rupnow, Tyson
    JOURNAL OF MATERIALS IN CIVIL ENGINEERING, 2019, 31 (02)
  • [23] Bond behavior between high-strength grout and rebar after exposure to elevated temperatures
    Liu, Lianglin
    Sun, Wenjuan
    Xiao, Jianzhuang
    Li, Weihua
    Jian, Luying
    Zhang, Qing
    STRUCTURES, 2024, 69
  • [24] Tests on the Steel–Concrete Bond Strength in Steel Reinforced Concrete (SRC) Columns After Fire Exposure
    Wei-Hua Wang
    Lin-Hai Han
    Qing-Hua Tan
    Zhong Tao
    Fire Technology, 2017, 53 : 917 - 945
  • [25] Shear behavior of steel reinforced recycled aggregate concrete beams after exposure to elevated temperatures
    Pan, Zuanfeng
    Zheng, Wei
    Xiao, Jianzhuang
    Chen, Zongping
    Chen, Yuliang
    Xu, Jinjun
    JOURNAL OF BUILDING ENGINEERING, 2022, 48
  • [26] Fracture behaviour of steel fibre reinforced recycled aggregate concrete after exposure to elevated temperatures
    Chen, G. M.
    Yang, H.
    Lin, Cj.
    Chen, J. F.
    He, Y. H.
    Zhang, H. Z.
    CONSTRUCTION AND BUILDING MATERIALS, 2016, 128 : 272 - 286
  • [27] Shear behavior of steel reinforced recycled aggregate concrete beams after exposure to elevated temperatures
    Pan, Zuanfeng
    Zheng, Wei
    Xiao, Jianzhuang
    Chen, Zongping
    Chen, Yuliang
    Xu, Jinjun
    JOURNAL OF BUILDING ENGINEERING, 2022, 48
  • [28] Compressive behavior of steel fiber reinforced recycled aggregate concrete after exposure to elevated temperatures
    Chen, G. M.
    He, Y. H.
    Yang, H.
    Chen, J. F.
    Guo, Y. C.
    CONSTRUCTION AND BUILDING MATERIALS, 2014, 71 : 1 - 15
  • [29] Bond-slip performance of water cooling steel-reinforced high-strength concrete after high temperature
    Pang, Shaohua
    Huang, Yuming
    Chen, Zongping
    Ye, Peihuan
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 19
  • [30] ACOUSTIC EMISSION AND BOND DEGRADATION IN REINFORCED CONCRETE DUE TO ELEVATED TEMPERATURES.
    Royles, R.
    Morley, P.D.