Acoustic inspection of bond strength of steel-reinforced mortar after exposure to elevated temperatures

被引:18
|
作者
Chiang, CH
Tsai, CL
Kan, YC
机构
[1] Chaoyang Univ Technol, Dept Construct Engn, Taichung 413, Taiwan
[2] Natl Yunlin Univ Sci & Technol, Dept Construct Engn, Touliu 640, Yunlin, Taiwan
关键词
acoustic inspection; bond strength; concrete; steel reinforcement;
D O I
10.1016/S0041-624X(99)00088-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
In order to evaluate the bond strength between the reinforcement and concrete after fire damage, a combination of acoustic through-transmission and pull-out tests were used. Previous studies have shown a 25% decrease in the ultrasonic pulse velocity at 90% of the maximum load at room temperature. The specimens were kept in the oven at an elevated temperature for 1, 2, or 3 h. They were then removed and cooled to room temperature. Inspection was conducted using a high-power ultrasonic pulse velocity system while a pull-out load was applied. The correlation between preheated temperature, acoustic wave velocity, and the applied load was analyzed. Initial results show that bond strength and pulse velocity decreased substantially as the temperature or the heating time increased. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:534 / 536
页数:3
相关论文
共 50 条
  • [1] Tensile and bond properties and strength degradation mechanism of geopolymer mortar after exposure to elevated temperatures
    Zhang, Haiyan
    Cao, Liang
    Wu, Bo
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2016, 48 (12): : 128 - 134
  • [2] Acoustic inspection of bond strength between mortar and reinforcement
    Chiang, CH
    Kan, YC
    Tang, CK
    Su, CS
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 17A AND 17B, 1998, : 1551 - 1556
  • [3] Residual Bond Behavior of Steel Reinforced Recycled Aggregate Concrete After Exposure to Elevated Temperatures
    Chen, Zongping
    Zhou, Ji
    Ban, Maogen
    Wang, Xinyue
    FRONTIERS IN MATERIALS, 2020, 7
  • [4] Bond strength between steel reinforcement and RCA concrete during and after exposure to elevated temperatures
    Yusuf, M.
    Sarhat, S.
    Hajiloo, H.
    Green, M. F.
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 345
  • [5] Strength and microstructure of seawater and sea sand mortar after exposure to elevated temperatures
    Xie, Qinghai
    Xiao, Jianzhuang
    Zong, Zhongling
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 322
  • [6] Bond strength of glass fiber-reinforced polymer bars in concrete after exposure to elevated temperatures
    El-Gamal, Sherif
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2014, 33 (23) : 2151 - 2163
  • [7] Bond strength of steel bars embedded in high-performance fiber-reinforced cementitious composite before and after exposure to elevated temperatures
    Li, Xiuling
    Bao, Yi
    Xue, Na
    Chen, Genda
    FIRE SAFETY JOURNAL, 2017, 92 : 98 - 106
  • [8] Parallel wires steel-reinforced polymer and mortar for structural strengthening: Introducing and bond properties
    Raji, Ali
    Ghaleh, Reza Zamani
    Mostofinejad, Davood
    ENGINEERING STRUCTURES, 2025, 323
  • [9] Residual bond strength between steel bars and concrete after elevated temperatures
    Bingol, A. Ferhat
    Gul, Ruestem
    FIRE SAFETY JOURNAL, 2009, 44 (06) : 854 - 859
  • [10] Flexural behavior of concrete beams reinforced with high-strength steel bars after exposure to elevated temperatures
    Zhao, Jun
    Jiang, Yibo
    Li, Xiaopeng
    CONSTRUCTION AND BUILDING MATERIALS, 2023, 382