Measurement of cyclic variation in ultrasonic integrated backscatter in conscious, unsedated, clinically normal dogs

被引:0
|
作者
Fuentes, VL
Moran, CM
Schober, K
McEwan, JD
Brown, H
Sutherland, GR
McDicken, WN
机构
[1] UNIV EDINBURGH, ROYAL DICK SCH VET STUDIES, DEPT VET CLIN STUDIES, EDINBURGH EH9 1QH, MIDLOTHIAN, SCOTLAND
[2] UNIV EDINBURGH, SCH MED, DEPT PUBL HLTH SCI, MED STAT UNIT, EDINBURGH, MIDLOTHIAN, SCOTLAND
[3] UNIV EDINBURGH, ROYAL INFIRM, DEPT MED PHYS & MED ENGN, EDINBURGH EH3 9YW, MIDLOTHIAN, SCOTLAND
[4] WESTERN GEN HOSP, DEPT CARDIOL, EDINBURGH EH4 2XU, MIDLOTHIAN, SCOTLAND
关键词
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To assess the feasibility and repeatability of measuring ultrasonic integrated backscatter in unsedated conscious dogs, using a protocol previously validated in pigs with open thorax. Animals-11 clinically normal conscious unsedated German Shorthair Pointers. Procedure-A modified commercially available echocardiography system was used to record long-axis views of the heart. The radiofrequency data from 15 consecutive frames were digitized and analyzed. Regions of interest were chosen within the myocardium, and the ultrasonic integrated backscatter within each region was calculated in the time domain far each frame. Results-Cyclic variation in integrated backscatter values was observed, with maximal values at end-diastole and minimal values at end-systole. Mean +/- SD amplitude of cyclic variation was 5.81 +/- 3.86 dB over all the regions chosen. Conclusions-Results agreed with those obtained by other investigators working with dogs with open thorax and those with closed thorax while under general anesthesia. The analysis of the components of variance indicates that this isa consistent, reliable technique in conscious unsedated dogs. Clinical Relevance-integrated ultrasonic backscatter measurement provides a noninvasive means of tissue characterization. Use of this protocol reliably yields cyclic variation in integrated backscatter and could be applied clinically to dogs with myocardial disease.
引用
收藏
页码:1055 / 1059
页数:5
相关论文
共 50 条
  • [21] CYCLIC VARIATION OF INTEGRATED BACKSCATTER OF THE MYOCARDIUM PARALLELS MYOCARDIAL THICKENING
    LEUNG, DY
    GRIMM, RA
    MOREHEAD, A
    RODRIGUEZ, LL
    GRIFFIN, BP
    CIRCULATION, 1994, 90 (04) : 608 - 608
  • [22] Cardiac cyclic variation of integrated backscatter in hypertension and dialysis patients
    Akar, H
    Ceyhan, C
    Yenicerioglu, Y
    Keven, K
    Onbasili, A
    Tekten, T
    JOURNAL OF NEPHROLOGY, 2004, 17 (02) : 270 - 274
  • [23] Cyclic variation of ultrasonic integrated backscatter is related to myocardial systolic function but not to interstitial fibrosis in clinical and experimental hypertrophy
    Vezzoli, M
    Ferrero, I
    Torretta, L
    Facoetti, A
    Nano, R
    Tozzi, R
    Palladini, G
    Pandolfo, A
    Fogari, R
    Perlini, S
    JOURNAL OF HYPERTENSION, 2003, 21 : S37 - S37
  • [24] Cyclic variation of ultrasonic integrated backscatter is related to myocardial systolic function but not to interstitial fibrosis in clinical and experimental hypertrophy
    Perlini, Stefano
    Palladini, Giuseppina
    Tozzi, Rossana
    Gatti, Chiara
    Busca, Giuseppe
    Ferrari, Alberto U.
    HYPERTENSION, 2007, 50 (04) : E147 - E147
  • [25] Normal values in children for myocardial ultrasonic tissue characterization by integrated backscatter
    Shibuya, K
    Bigras, JL
    McCrindle, BW
    Newman, A
    Smallhorn, JF
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1998, 15 (04): : 353 - 361
  • [26] Ultrasonic integrated backscatter cyclic variation is related to myocardial systolic function but not to interstitial fibrosis in left-ventricular hypertrophy
    Vezzoli, M
    Ferrero, I
    Torretta, L
    Nano, R
    Tozzi, R
    Palladini, G
    Fogari, R
    Perlini, S
    EUROPEAN HEART JOURNAL, 2003, 24 : 456 - 456
  • [27] Novel ultrasonic fusion imaging method based on cyclic variation in myocardial backscatter
    J. Bai
    Y. Jiang
    X. Li
    D. Pan
    G. Hu
    P. He
    Medical and Biological Engineering and Computing, 2002, 40 : 163 - 167
  • [28] Novel ultrasonic fusion imaging method based on cyclic variation in myocardial backscatter
    Bai, J
    Jiang, Y
    Li, X
    Pan, D
    Hu, G
    He, P
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2002, 40 (02) : 163 - 167
  • [29] MYOCARDIAL ULTRASONIC BACKSCATTER - PHYSIOLOGICAL AND PHYSICAL DETERMINANTS OF THE CARDIAC CYCLE-DEPENDENT VARIATION OF INTEGRATED BACKSCATTER
    WICKLINE, SA
    THOMAS, LJ
    MILLER, JG
    SOBEL, BE
    PEREZ, JE
    CLINICAL RESEARCH, 1985, 33 (02): : A237 - A237
  • [30] Differential effects of chronic beta blockade versus sympathectomy on ultrasonic integrated backscatter cyclic variation in pressure-overload hypertrophy
    Perlini, S
    Ferrero, I
    Vezzoli, M
    Mussida, M
    Tozzi, R
    Palladini, G
    Fallarini, S
    Busca, G
    Ferrari, AU
    CIRCULATION, 2003, 108 (17) : 690 - 690