Measurement of cyclic variation in ultrasonic integrated backscatter in conscious, unsedated, clinically normal dogs

被引:0
|
作者
Fuentes, VL
Moran, CM
Schober, K
McEwan, JD
Brown, H
Sutherland, GR
McDicken, WN
机构
[1] UNIV EDINBURGH, ROYAL DICK SCH VET STUDIES, DEPT VET CLIN STUDIES, EDINBURGH EH9 1QH, MIDLOTHIAN, SCOTLAND
[2] UNIV EDINBURGH, SCH MED, DEPT PUBL HLTH SCI, MED STAT UNIT, EDINBURGH, MIDLOTHIAN, SCOTLAND
[3] UNIV EDINBURGH, ROYAL INFIRM, DEPT MED PHYS & MED ENGN, EDINBURGH EH3 9YW, MIDLOTHIAN, SCOTLAND
[4] WESTERN GEN HOSP, DEPT CARDIOL, EDINBURGH EH4 2XU, MIDLOTHIAN, SCOTLAND
关键词
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective-To assess the feasibility and repeatability of measuring ultrasonic integrated backscatter in unsedated conscious dogs, using a protocol previously validated in pigs with open thorax. Animals-11 clinically normal conscious unsedated German Shorthair Pointers. Procedure-A modified commercially available echocardiography system was used to record long-axis views of the heart. The radiofrequency data from 15 consecutive frames were digitized and analyzed. Regions of interest were chosen within the myocardium, and the ultrasonic integrated backscatter within each region was calculated in the time domain far each frame. Results-Cyclic variation in integrated backscatter values was observed, with maximal values at end-diastole and minimal values at end-systole. Mean +/- SD amplitude of cyclic variation was 5.81 +/- 3.86 dB over all the regions chosen. Conclusions-Results agreed with those obtained by other investigators working with dogs with open thorax and those with closed thorax while under general anesthesia. The analysis of the components of variance indicates that this isa consistent, reliable technique in conscious unsedated dogs. Clinical Relevance-integrated ultrasonic backscatter measurement provides a noninvasive means of tissue characterization. Use of this protocol reliably yields cyclic variation in integrated backscatter and could be applied clinically to dogs with myocardial disease.
引用
收藏
页码:1055 / 1059
页数:5
相关论文
共 50 条
  • [1] Influence of Contractility on Myocardial Ultrasonic Integrated Backscatter and Cyclic Variation in Integrated Backscatter
    毕小军
    邓又斌
    潘敏
    杨好意
    向慧娟
    常青
    黎春雷
    Current Medical Science, 2002, (03) : 233 - 234
  • [2] Influence of contractility on myocardial ultrasonic integrated backscatter and cyclic variation in integrated backscatter
    Bi Xiaojun
    Deng Youbin
    Pan Min
    Yang Haoyi
    Xiang Huijuan
    Chang Qing
    Li Chunlei
    Current Medical Science, 2002, 22 (3) : 233 - 234
  • [3] IBR5 - AN OPTIMAL MEASUREMENT OF INTEGRATED BACKSCATTER AND CYCLIC VARIATION OF INTEGRATED BACKSCATTER
    RHYNE, TL
    SAGAR, KB
    ULTRASONIC IMAGING, 1990, 12 (03) : 189 - 204
  • [4] REDUCED CYCLIC VARIATION OF ULTRASONIC INTEGRATED BACKSCATTER DURING MYOCARDIAL CONTRAST
    MELTZER, RS
    OHAD, DG
    REISNER, SA
    SUCHER, E
    KAPLINSKY, E
    MOTRO, M
    BATTLER, A
    VERED, Z
    CIRCULATION, 1993, 88 (04) : 163 - 163
  • [5] Cyclic variation of myocardial integrated backscatter ultrasonic signal in hypertensive cardiomyopathy
    Di Bello, V
    Pedrinelli, R
    Bertini, A
    Giorgi, D
    Talini, E
    Cioppi, A
    Dell'Omo, G
    Moretti, L
    Giusti, C
    EUROPEAN HEART JOURNAL, 2000, 21 : 619 - 619
  • [6] REDUCTION OF CYCLIC VARIATION OF INTEGRATED BACKSCATTER - AN ULTRASONIC CHARACTERISTIC OF DILATED CARDIOMYOPATHY
    VERED, Z
    MOHR, G
    WEAR, K
    GENTON, R
    BARZILAI, B
    MILLER, J
    SOBEL, B
    PEREZ, J
    CIRCULATION, 1987, 76 (04) : 43 - 43
  • [7] CYCLIC VARIATION IN ULTRASONIC PROPAGATION PROPERTIES - MECHANISM FOR CYCLIC VARIATION IN ULTRASONIC BACKSCATTER
    OBRIEN, PD
    OBRIEN, WD
    RHYNE, TL
    NAFKOWSKI, J
    WARLTIER, DC
    SAGAR, KB
    CLINICAL RESEARCH, 1992, 40 (03): : A750 - A750
  • [8] Blunted cyclic variation of ultrasonic integrated backscatter in asymptomatic patients with type 1 diabetes and normal ejection fraction
    Renzi, M
    Coletta, C
    Chiaramonte, F
    Sestili, A
    Aspromonte, N
    Amici, E
    Romano, P
    Malarbi, A
    Ceci, V
    EUROPEAN HEART JOURNAL, 2000, 21 : 339 - 339
  • [9] Angle dependence and reproducibility of cyclic variation of integrated backscatter in normal myocardium
    Stempfle, HU
    Buchmeier, U
    Werner, C
    Theisen, K
    Angermann, CE
    COMPUTERS IN CARDIOLOGY 1997, VOL 24, 1997, 24 : 541 - 543
  • [10] Influences of ultrasonic machine settings, transducer frequency and placement of region of interest on the measurement of integrated backscatter and cyclic variation
    Ota, T
    Craig, DM
    Kisslo, J
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (07): : 1059 - 1070