Preliminary Investigation of Active Demand Flexibility Control at Air-Handling Units Using Energy Feedback Control

被引:0
|
作者
Hurt, Rodney [1 ]
Wang, Zufen [2 ]
Wang, Gang [2 ]
Andiroglu, Esber [2 ]
Song, Li [1 ]
机构
[1] Univ Oklahoma, Dept Aerosp & Mech Engn, Norman, OK 73019 USA
[2] Univ Miami, Dept Civil Architectural & Environm Engn, Coral Gables, FL USA
来源
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Grid-interactive efficient buildings (GEBs) require quick and accurate manipulation of flexible electrical loads. Heating, ventilating, and air conditioning (HVAC) loads are particularly well suited for demand flexibility control by utilizing thermal mass in building structures. The HVAC load and its responding zone temperature (ZT) can be optimized by model predictive control (MPC) to minimize the operation cost with the indoor comfort constraint. However, due to the lack of reliable and affordable energy meters, the current HVAC demand control is implemented using ZT feedback control with the responding ZT optimized by MPC as the setpoint and the HVAC load as the response. Unfortunately, the building thermal mass makes the actual HVAC load significantly different than the optimized HVAC load, which is the on-demand setpoint, with potential demand penalty. Low-cost virtual flow meter technology makes the cooling load measurement at air handling units (AHUs) available, thus energy feedback control can be applied to actively control the cooling load of AHUs at its on-demand setpoint. The objective of the paper is to preliminarily investigate the demand flexibility control performance of the energy feedback control at AHUs. First, the energy feedback control at AHUs is introduced. Then, the performance of a single zone AHU is simulated and compared between the ZT feedback control and energy feedback control. Finally, a field experiment is conducted on a 7-ton single duct variable air volume AHU with these two different controls. Experimental results show that the cooling load with the current ZT feedback control drops to the on-demand setpoint after 25 minutes. On the other hand, the energy feedback control can reduce the cooling load to the on-demand setpoint in less than 3 minutes. Therefore, the active energy feedback control can significantly advance the current ZT feedback control by quickly and accurately controlling the cooling load at AHUs to avoid the demand penalty.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [31] Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building
    Yoon, Yeobeom
    Seo, Byeongmo
    Cho, Soolyeon
    BUILDINGS, 2023, 13 (05)
  • [33] Model predictive control of supply air temperature and outside air intake rate of a VAV air-handling unit
    Yuan, Shui
    Perez, Ronald A.
    ASHRAE Transactions 2006, Vol 112, Pt 1, 2006, 112 : 145 - 161
  • [34] Evaluation of supply air temperature control performance with different control strategies at air handling units
    Wang, Zufen
    Hashem, Marwan R.
    Song, Li
    Wang, Gang
    BUILDING AND ENVIRONMENT, 2023, 243
  • [35] Neural-based air-handling unit for indoor relative humidity and temperature control
    Zhang, Q
    Wong, YW
    Fok, SC
    Bong, TY
    ASHRAE Transactions 2005, Vol 111, Pt 1, 2005, 111 : 63 - 70
  • [36] Feedback control and acoustical energy in active noise control
    Pota, HR
    He, BR
    42ND IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-6, PROCEEDINGS, 2003, : 6381 - 6385
  • [37] Improving the nonlinear control performance of the supply fan at air handling units using a gain scheduling control strategy
    Wang, Zufen
    Hurt, Rodney
    Song, Li
    Wang, Gang
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2022, 28 (09) : 1201 - 1212
  • [38] Improving Valve Operation Using Cascade Control in Single Zone Air Handling Units
    Phalak, Kaustubh
    Wang, Gang
    Varona, Jose
    2016 ASHRAE ANNUAL CONFERENCE PAPERS, 2016,
  • [39] A Multi-Objective Approach to Robust Control of Air Handling Units for Optimized Energy Performance
    Wani, Mubashir
    Hafiz, Faizal
    Swain, Akshya
    Ukil, Abhisek
    ELECTRONICS, 2023, 12 (03)
  • [40] Optimal outside airflow control of an integrated air-handling unit system for large office buildings
    Song, L
    Liu, M
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2004, 126 (01): : 614 - 619