Preliminary Investigation of Active Demand Flexibility Control at Air-Handling Units Using Energy Feedback Control

被引:0
|
作者
Hurt, Rodney [1 ]
Wang, Zufen [2 ]
Wang, Gang [2 ]
Andiroglu, Esber [2 ]
Song, Li [1 ]
机构
[1] Univ Oklahoma, Dept Aerosp & Mech Engn, Norman, OK 73019 USA
[2] Univ Miami, Dept Civil Architectural & Environm Engn, Coral Gables, FL USA
来源
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Grid-interactive efficient buildings (GEBs) require quick and accurate manipulation of flexible electrical loads. Heating, ventilating, and air conditioning (HVAC) loads are particularly well suited for demand flexibility control by utilizing thermal mass in building structures. The HVAC load and its responding zone temperature (ZT) can be optimized by model predictive control (MPC) to minimize the operation cost with the indoor comfort constraint. However, due to the lack of reliable and affordable energy meters, the current HVAC demand control is implemented using ZT feedback control with the responding ZT optimized by MPC as the setpoint and the HVAC load as the response. Unfortunately, the building thermal mass makes the actual HVAC load significantly different than the optimized HVAC load, which is the on-demand setpoint, with potential demand penalty. Low-cost virtual flow meter technology makes the cooling load measurement at air handling units (AHUs) available, thus energy feedback control can be applied to actively control the cooling load of AHUs at its on-demand setpoint. The objective of the paper is to preliminarily investigate the demand flexibility control performance of the energy feedback control at AHUs. First, the energy feedback control at AHUs is introduced. Then, the performance of a single zone AHU is simulated and compared between the ZT feedback control and energy feedback control. Finally, a field experiment is conducted on a 7-ton single duct variable air volume AHU with these two different controls. Experimental results show that the cooling load with the current ZT feedback control drops to the on-demand setpoint after 25 minutes. On the other hand, the energy feedback control can reduce the cooling load to the on-demand setpoint in less than 3 minutes. Therefore, the active energy feedback control can significantly advance the current ZT feedback control by quickly and accurately controlling the cooling load at AHUs to avoid the demand penalty.
引用
收藏
页码:59 / 66
页数:8
相关论文
共 50 条
  • [21] Humidity and temperature nonlinear control based on almost disturbance decoupling and state observers for air-handling units
    Liu, Guangxu
    Liu, Xiaoping
    Liu, Cungen
    Sun, Yulong
    Liu, Li
    NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 2024,
  • [22] AIR-HANDLING UNIT SUPPLY AIR TEMPERATURE OPTIMAL ECONOMIZER CONTROL EXPERIMENT
    Thomas, Wesley
    Song, Li
    Shim, Gyujin
    Wang, Gang
    INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 6, PTS A AND B, 2013, : 1347 - 1358
  • [23] A damper control system for preventing reverse airflow through the exhaust air damper of variable-air-volume air-handling units
    Seem, JE
    House, JM
    Kelly, GE
    Klaassen, CJ
    HVAC&R RESEARCH, 2000, 6 (02): : 135 - 148
  • [24] Damper control system for preventing reverse airflow through the exhaust air damper of variable-air-volume air-handling units
    Seem, John E.
    House, John M.
    Kelly, George E.
    Klaassen, Curtis J.
    ASHRAE Transactions, 2000, 106 (PA
  • [25] NONLINEAR CONTROL OF AN AIR HANDLING UNIT USING FEEDBACK LINEARIZATION
    Moradi, Hamed
    Saffar-Avval, Majid
    IMECE 2009: PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, VOL 9, PTS A-C, 2010, : 891 - 897
  • [26] AN INTEGRATED OUTSIDE AIR CONTROL OF AIR HANDLING UNITS IN OFFICE BUILDINGS FOR ENERGY EFFICIENCY
    Yu, Y. B.
    Liu, M. S.
    Yu, D. H.
    Loftness, V.
    7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 1265 - 1271
  • [27] A control system that prevents air from entering an air-handling unit through the exhaust air
    Seem, JE
    House, JM
    17TH AIVC CONFERENCE - OPTIMUM VENTILATION AND AIR FLOW CONTROL IN BUILDING, PROCEEDINGS, VOLS 1 AND 2, 1996, : 561 - 569
  • [28] Demand Flexibility Evaluation for Building Energy Systems with Active Thermal Storage Using Model Predictive Control
    Li, Guowen
    Fu, Yangyang
    Pertzborn, Amanda
    O'Neill, Zheng
    Wen, Jin
    ASHRAE TRANSACTIONS 2022, VOL 128, PT 2, 2022, 128 : 650 - 658
  • [29] Experimental investigation of solar energy-aided air-handling units using a double-tube double-stage heat pipe exchanger
    Abdelrahman S.A.
    Dawood M.M.K.
    Shehata A.I.
    Nabil T.
    International Journal of Energy for a Clean Environment, 2021, 22 (06) : 35 - 53
  • [30] On a control policy that maintains indoor air quality in a variable-air-volume air-handling unit
    Norris, WR
    Sreenivas, RS
    PROCEEDINGS OF THE 1997 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, 1997, : 886 - 891