Fibrinogen-coated bismuth film electrodes for voltammetric analysis of lead and cadmium using the batch injection analysis

被引:21
|
作者
Adraoui, I.
Rhazi, M. E.
Amine, A.
机构
关键词
batch injection analysis; fibrinogen; bismuth film; surfactants; heavy metals; stripping;
D O I
10.1080/00032710600964676
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the application of fibrinogen-coated bismuth films deposited on carbon paste electrodes (Fbg-BiFEs) for the simultaneous determination of trace amounts of lead and cadmium by square-wave anodic stripping voltammetry, combined with a batch injection analysis technique (BIA-SWASV). The batch injection analysis system provides the advantages of rapid and simple electroanalysis of microliter samples. Its use in combination with Fbg-BiFEs allowed the determination of metals at trace levels in environmental samples, given that the surfactant interference observed with stripping analysis at bismuth electrodes could be minimized by use of a fibrinogen coating. The analytical characteristics, namely sensitivity, detection limits, and resistance to surfactants in the anodic stripping voltammetry of lead and cadmium, were investigated in acetate buffer. The resulting limits of detection were 0.2 mu g L-1 and 0.1 mu g L-1, for Cd and Pb respectively. Finally, the system based on Fbg-BiFEs combined with BIA-SWASV was applied to different real samples ( tap water and tea samples) for analysis of trace metals with satisfactory results.
引用
收藏
页码:349 / 367
页数:19
相关论文
共 50 条
  • [31] Voltammetric studies of cadmium- and zinc-containing metallothioneins at Nafion-coated mercury thin film electrodes
    Fu, Ying
    Xu, Maotian
    Li, Xue
    Du, Ming
    Wang, Jianxiu
    Zhou, Feimeng
    ELECTROANALYSIS, 2008, 20 (08) : 888 - 893
  • [32] Screen-printed carbon electrodes modified with a bismuth film for stripping voltammetric analysis of platinum group metals in environmental samples
    Silwana, Bongiwe
    van der Horst, Charlton
    Iwuoha, Emmanuel
    Somerset, Vernon
    ELECTROCHIMICA ACTA, 2014, 128 : 119 - 127
  • [33] Anodic Stripping Voltammetry for Simultaneous Determination of Lead and Cadmium using Bismuth-based Electrodes
    Pratiwi, Nur Hasanah
    Azis, Muhammad Yudhistira
    Setyorini, Dian Ayu
    Rahayu, Ria Sri
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (03): : 331 - 347
  • [34] Determination of lead and cadmium by anodic stripping voltammetry at bismuth film electrodes following double deposition and stripping steps
    Rutyna, Iwona
    Korolczuk, Mieczyslaw
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 136 - 141
  • [35] Anodic stripping voltammetric determination of bismuth(III) using a Tosflex-coated mercury film electrode
    Yang, HY
    Chen, WY
    Sun, IW
    TALANTA, 1999, 50 (05) : 977 - 984
  • [36] A Study of Nafion-Coated Bismuth-Film Electrode for the Determination of Zinc, Lead, and Cadmium in Blood Samples
    Liu, Benzhi
    Lu, Liyuan
    Wang, Min
    Zi, Yanqin
    ELECTROANALYSIS, 2008, 20 (21) : 2363 - 2369
  • [37] Simple Voltammetric Determination of Iron in Ethanol and Biodiesel Using a Bismuth Film Coated Glassy Carbon Electrode
    Almeida, Joseany M. S.
    Ribeiro, Ana Beatriz P.
    Toloza, Carlos A. T.
    Alves, Ismael C. B.
    Santos, Jose Ribamar N.
    De Azevedo, Lorena C. M.
    Aucelio, Ricardo Q.
    Marques, Aldalea L. B.
    ANALYTICAL LETTERS, 2022, 55 (15) : 2325 - 2346
  • [38] Bismuth film electrode for analysis of tetracycline in flow injection system
    Sattayasamitsathit, Sirilak
    Thavarungkul, Panote
    Kanatharana, Proespichaya
    ELECTROANALYSIS, 2007, 19 (04) : 502 - 505
  • [39] Stripping voltammetric analysis of zinc, cadmium, lead, and copper ions in chloride solutions
    Grilikhes, MS
    Demin, VA
    Nadezhina, LS
    RUSSIAN JOURNAL OF APPLIED CHEMISTRY, 1997, 70 (07) : 1063 - 1066