Determination of lead and cadmium by anodic stripping voltammetry at bismuth film electrodes following double deposition and stripping steps

被引:45
|
作者
Rutyna, Iwona [1 ]
Korolczuk, Mieczyslaw [1 ]
机构
[1] Marie Curie Sklodowska Univ, Fac Chem, PL-20031 Lublin, Poland
关键词
Stripping analysis; Double deposition; Lead; Cadmium; HIGH-SENSITIVITY DETERMINATION; CARBON-PASTE ELECTRODE; TRACE-METALS; IN-SITU; ELECTROCHEMICAL DETERMINATION; MICROELECTRODE ARRAYS; COMPOSITE FILM; PLATED CARBON; IONS; CD(II);
D O I
10.1016/j.snb.2014.07.091
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The double deposition and stripping steps were proposed to increase the sensitivity in anodic stripping voltammetry of lead and cadmium. Two in situ plated bismuth film electrodes at drastically different surface areas were used for the measurements. Cadmium and lead were at first deposited at the electrode with a large surface area. When the deposition step at the electrode was finished, the electrode was placed at a short distance opposite the small one. Then Cd(II) and Pb(II) stripped from the first electrode were deposited at the second electrode. Taking into account the small volume of space between the electrodes, the concentration of Pb(II) and Cd(II) between the electrodes was drastically higher than that in the bulk solution. The deposition step at the second electrode was performed from the solution with a higher concentration of the determined ions, and so the detection limit was lowered. Calibration was performed following deposition times of 300 and 120 s at the first and the second electrode, respectively. Under such conditions the detection limits of 1.8 X 10(-10) and 4.5 x 10(-11) mol L-1 for Pb(II) and Cd(II) were obtained, respectively (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [1] Determination of Ultratrace Thallium(I) by Anodic Stripping Voltammetry at Bismuth Film Electrodes Following Double Deposition and Stripping Steps
    Rutyna, Iwona
    Korolczuk, Mieczyslaw
    [J]. ELECTROANALYSIS, 2014, 26 (12) : 2639 - 2643
  • [2] Determination of As(III) by anodic stripping voltammetry following double deposition and stripping steps at two gold working electrodes
    Korolczuk, Mieczyslaw
    Ochab, Mateusz
    Rutyna, Iwona
    [J]. TALANTA, 2015, 144 : 517 - 521
  • [3] Determination of trace Se(IV) by anodic stripping voltammetry following double deposition and stripping steps
    Ochab, Mateusz
    Geca, Iwona
    Korolczuk, Mieczyslaw
    [J]. TALANTA, 2017, 165 : 364 - 368
  • [4] Anodic stripping voltammetry following double deposition and stripping steps: Application of a new approach in the course of lead ion determination
    Geca, Iwona
    Korolczuk, Mieczyslaw
    [J]. TALANTA, 2017, 171 : 321 - 326
  • [5] Anodic Stripping Voltammetry for Simultaneous Determination of Lead and Cadmium using Bismuth-based Electrodes
    Pratiwi, Nur Hasanah
    Azis, Muhammad Yudhistira
    Setyorini, Dian Ayu
    Rahayu, Ria Sri
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2022, 14 (03): : 331 - 347
  • [6] Nafion-coated bismuth film electrodes for the determination of trace lead and cadmium in herbal medicines by anodic stripping voltammetry
    Xu He
    Zeng Li-Ping
    Xing Su-Jie
    Xian Yue-Zhong
    Jin Li-Tong
    [J]. CHINESE JOURNAL OF CHEMISTRY, 2008, 26 (05) : 847 - 853
  • [7] Double Deposition and Stripping Steps for Trace Determination of Au(III) Using Anodic Stripping Voltammetry
    Rutyna, Iwona
    Ochab, Mateusz
    Korolczuk, Mieczyslaw
    [J]. ELECTROANALYSIS, 2015, 27 (10) : 2486 - 2491
  • [8] Quantitative determination of zinc in milkvetch by anodic stripping voltammetry with bismuth film electrodes
    Guo, ZY
    Feng, F
    Hou, YX
    Jaffrezic-Renault, N
    [J]. TALANTA, 2005, 65 (04) : 1052 - 1055
  • [9] Bismuth Film Anodic Stripping Voltammetry for the Determination of Lead in Kerosene: A Metrological Study
    Miguel, Eliane M.
    da Cunha, Alessandra Licursi M. C.
    Pacheco, Wagner F.
    Farias, Percio A. M.
    Aucelio, Ricardo Q.
    [J]. ELECTROANALYSIS, 2010, 22 (13) : 1505 - 1510
  • [10] A study of pencil-lead bismuth-film electrodes for the determination of trace metals by anodic stripping voltammetry
    Demetriades, D
    Economou, A
    Voulgaropoulos, A
    [J]. ANALYTICA CHIMICA ACTA, 2004, 519 (02) : 167 - 172