Distortion of Right Superior Pulmonary Vein Anatomy by Balloon Catheters as a Contributor to Phrenic Nerve Injury

被引:19
|
作者
不详
机构
[1] Department of Internal Medicine, Translational Cardiac Electrophysiology Laboratory, Division of Cardiovascular Disease, Rochester, MI
[2] Mayo Clinic/Saint Mary's Hospital, 2-416 Alfred Building, Rochester, MN 55902
关键词
ablation; atrial fibrillation; balloon catheter; phrenic nerve injury; cryoablation; INTENSITY FOCUSED ULTRASOUND; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; CRYOBALLOON; EFFICACY; COMPLICATION; SAFETY;
D O I
10.1111/j.1540-8167.2009.01495.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
RSPV Distortion by Balloon Catheter. Introduction: Cryothermal, HIFU, and laser catheter-based balloon technologies have been developed to simplify ablation for AF. Initial enthusiasm for their widespread use has been dampened by phrenic nerve (PN) injury. The interaction between PN and pulmonary vein (PV) geometry contributing to PN injury is unclear. Methods and Results: After right thoracotomy, the PN course along the epicardial right atrial surface was mapped directly in 10 dogs. The location of the PN and its relationship with the right superior (RS) PV, and potential RSPV surface distortions after balloon inflation were established by electroanatomic mapping. In 5 dogs, the PN was captured within the RSPV, but could not be stimulated in the remaining 5 dogs. The distance between the RSPV and the PN was significantly shorter in the captured group than in the noncaptured group (6.3 +/- 3.1 mm vs 10.2 +/- 3.2 mm, P < 0.001). Importantly, 96% of the captured sites within the RSPV were observed at a distance > 5 mm into the PV. The inflated balloon surface anteriorly extended 5.6 +/- 3.7 mm outside the PV diameter, with distortion of anatomy narrowing the distance from the balloon surface to the PN to 4.8 +/- 2.3 mm. (Distance of the original RSPV-to-PN: 9.4 +/- 2.7 mm, P < 0.001.) Conclusion: PN injury with balloon technologies may stem fromanatomic distortion of the PV orifice/PN relationship, through increasing contact or shortening the relative distance between the ablation site and the PN, even without displacement of the balloon into the PV. These data are important in the refinement of these technologies to improve procedural safety. (J Cardiovasc Electrophysiol, Vol. 20, pp. 1151-1157, October 2009)
引用
收藏
页码:1151 / 1157
页数:7
相关论文
共 50 条
  • [41] Electrical Isolation of the Superior Vena Cava Using Upstream Phrenic Pacing to Avoid Phrenic Nerve Injury
    Kimura, Takehiro
    Takatsuki, Seiji
    Fukumoto, Kotaro
    Nishiyama, Nobuhiro
    Sato, Yuriko
    Aizawa, Yoshiyasu
    Fukuda, Yukiko
    Sato, Toshiaki
    Miyoshi, Shunichiro
    Fukuda, Keiichi
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (09): : 1053 - 1060
  • [42] Regression of phrenic nerve injury after balloon cryocatheter ablation of atrial fibrillation
    Kuniss, M.
    Kurzidim, K.
    Schmitt, J.
    Zaltsberg, S.
    Sperzel, J.
    Hamm, C.
    Pitschner, H. F.
    EUROPEAN HEART JOURNAL, 2006, 27 : 728 - 728
  • [43] Isolation of the Right Superior Pulmonary Vein Requiring Superior Limbus Ablation From the Right Atrium
    van Zyl, Martin
    Deshmukh, Abhishek J.
    Asirvatham, Samuel J.
    DeSimone, Christopher, V
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2023, 9 (04) : 603 - 606
  • [44] RIGHT PHRENIC-NERVE INJURY IN ORTHOTOPIC LIVER-TRANSPLANTATION
    MCALISTER, VC
    GRANT, DR
    ROY, A
    BROWN, WF
    HUTTON, LC
    LEASA, DJ
    GHENT, CN
    VEITCH, JE
    WALL, WJ
    EDMOND
    TRANSPLANTATION, 1993, 55 (04) : 826 - 830
  • [45] Comparison of phrenic nerve injury and its effect on the extrapulmonary vein structures with cryoballoon and hot-balloon ablation systems: considering the lesion created on the superior vena cava as a surrogate marker
    Yuichi Hori
    Shiro Nakahara
    Hideyuki Aoki
    Hirotsugu Sato
    Reiko Fukuda
    Zhensheng Hua
    Yuri Koshikawa
    Yukiko Mizutani
    Hidehiko Nakamura
    Itaru Hisauchi
    Yuji Itabashi
    Tetsuya Ishikawa
    Sayuki Kobayashi
    Isao Taguchi
    Heart and Vessels, 2023, 38 : 711 - 720
  • [46] Comparison of phrenic nerve injury and its effect on the extrapulmonary vein structures with cryoballoon and hot-balloon ablation systems: considering the lesion created on the superior vena cava as a surrogate marker
    Hori, Yuichi
    Nakahara, Shiro
    Aoki, Hideyuki
    Sato, Hirotsugu
    Fukuda, Reiko
    Hua, Zhensheng
    Koshikawa, Yuri
    Mizutani, Yukiko
    Nakamura, Hidehiko
    Hisauchi, Itaru
    Itabashi, Yuji
    Ishikawa, Tetsuya
    Kobayashi, Sayuki
    Taguchi, Isao
    HEART AND VESSELS, 2023, 38 (05) : 711 - 720
  • [47] ABNORMAL DRAINAGE OF THE SUPERIOR VENA-CAVA INTO THE RIGHT SUPERIOR PULMONARY VEIN
    OBERHANSLI, I
    FLIEDLI, B
    FAIDUTTI, B
    HERZ KREISLAUF, 1982, 14 (12): : 668 - 668
  • [48] The Incidence of Phrenic Nerve Injury During Pulmonary Vein Isolation Using the Second-Generation 28 mm Cryoballoon
    Metzner, Andreas
    Rausch, Peter
    Lemes, Christine
    Reissmann, Bruno
    Bardyszewski, Alexander
    Tilz, Roland
    Rillig, Andreas
    Mathew, Shibu
    Deiss, Sebastian
    Kamioka, Masashi
    Toennis, Tobias
    Lin, Tina
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Wissner, Erik
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (05) : 466 - 470
  • [49] Clinical feasibility of pulmonary vein orifice pacing for the prediction of phrenic nerve injury during cryoballoon ablation of atrial fibrillation
    Sano, Makoto
    Urushida, Tsuyoshi
    Matsukura, Gaku
    Sakakibara, Tomoaki
    Suwa, Kenichiro
    Naruse, Yoshihisa
    Ohtani, Hayato
    Saotome, Masao
    Maekawa, Yuichiro
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (08) : 1200 - 1206
  • [50] Phrenic nerve injury during pulmonary vein isolation by radiofrequency. An infrequent, disabling but mostly avoidable complication.
    Deceuninck, O.
    Xhaet, O.
    Dormal, F.
    Purnode, P.
    Blommaert, D.
    ACTA CARDIOLOGICA, 2018, 73 (05) : 482 - 483