Distortion of Right Superior Pulmonary Vein Anatomy by Balloon Catheters as a Contributor to Phrenic Nerve Injury

被引:19
|
作者
不详
机构
[1] Department of Internal Medicine, Translational Cardiac Electrophysiology Laboratory, Division of Cardiovascular Disease, Rochester, MI
[2] Mayo Clinic/Saint Mary's Hospital, 2-416 Alfred Building, Rochester, MN 55902
关键词
ablation; atrial fibrillation; balloon catheter; phrenic nerve injury; cryoablation; INTENSITY FOCUSED ULTRASOUND; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; CRYOBALLOON; EFFICACY; COMPLICATION; SAFETY;
D O I
10.1111/j.1540-8167.2009.01495.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
RSPV Distortion by Balloon Catheter. Introduction: Cryothermal, HIFU, and laser catheter-based balloon technologies have been developed to simplify ablation for AF. Initial enthusiasm for their widespread use has been dampened by phrenic nerve (PN) injury. The interaction between PN and pulmonary vein (PV) geometry contributing to PN injury is unclear. Methods and Results: After right thoracotomy, the PN course along the epicardial right atrial surface was mapped directly in 10 dogs. The location of the PN and its relationship with the right superior (RS) PV, and potential RSPV surface distortions after balloon inflation were established by electroanatomic mapping. In 5 dogs, the PN was captured within the RSPV, but could not be stimulated in the remaining 5 dogs. The distance between the RSPV and the PN was significantly shorter in the captured group than in the noncaptured group (6.3 +/- 3.1 mm vs 10.2 +/- 3.2 mm, P < 0.001). Importantly, 96% of the captured sites within the RSPV were observed at a distance > 5 mm into the PV. The inflated balloon surface anteriorly extended 5.6 +/- 3.7 mm outside the PV diameter, with distortion of anatomy narrowing the distance from the balloon surface to the PN to 4.8 +/- 2.3 mm. (Distance of the original RSPV-to-PN: 9.4 +/- 2.7 mm, P < 0.001.) Conclusion: PN injury with balloon technologies may stem fromanatomic distortion of the PV orifice/PN relationship, through increasing contact or shortening the relative distance between the ablation site and the PN, even without displacement of the balloon into the PV. These data are important in the refinement of these technologies to improve procedural safety. (J Cardiovasc Electrophysiol, Vol. 20, pp. 1151-1157, October 2009)
引用
收藏
页码:1151 / 1157
页数:7
相关论文
共 50 条
  • [21] First report of phrenic nerve injury during pulmonary vein isolation using the Ablation Frontiers pulmonary vein ablation catheter
    Syed Y. Ahsan
    Andrew S. Flett
    Pier D. Lambiase
    Oliver R. Segal
    Journal of Interventional Cardiac Electrophysiology, 2010, 29 : 187 - 190
  • [22] First report of phrenic nerve injury during pulmonary vein isolation using the Ablation Frontiers pulmonary vein ablation catheter
    Ahsan, Syed Y.
    Flett, Andrew S.
    Lambiase, Pier D.
    Segal, Oliver R.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 29 (03) : 187 - 190
  • [23] Right phrenic nerve palsy as a complication of indwelling central venous catheters
    Rigg, A
    Hughes, P
    Lopez, A
    Filshie, J
    Cunningham, D
    Green, M
    THORAX, 1997, 52 (09) : 831 - 833
  • [24] Predictors of Phrenic Nerve Injury During Pulmonary Vein Isolation for Curing Atrial Fibrillation With Balloon-Based Visually Guided Laser Ablation
    Tachibana, Shinichi
    Okishige, Kaoru
    Sudo, Koji
    Shigeta, Takatoshi
    Sagawa, Yuichiro
    Nakamura, Rena
    Kurabayashi, Manabu
    Yamauchi, Yasuteru
    Goya, Masahiko
    Sasano, Tetsuo
    CIRCULATION JOURNAL, 2021, 85 (03) : 275 - 282
  • [25] Phrenic nerve injury during right inferior pulmonary vein ablation with the second-generation cryoballoon: clinical, procedural, and anatomical characteristics
    Abugattas, Juan-Pablo
    de Asmundis, Carlo
    Iacopino, Saverio
    Salghetti, Francesca
    Takarada, Ken
    Coutino, Hugo-Enrique
    Stroker, Erwin
    De Regibus, Valentina
    de Greef, Yves
    Brugada, Pedro
    Sieira, Juan
    Chierchia, Gian-Battista
    EUROPACE, 2018, 20 (10): : E156 - E163
  • [26] Electroanatomical mapping to assess phrenic nerve proximity to superior vena cava (SVC) and pulmonary vein (PV) ostia
    Lowe, MD
    Peterson, LA
    Monahan, KH
    Asirvatham, SJ
    Packer, DL
    HEART, 2004, 90 : A10 - A10
  • [27] Double potentials in the right superior pulmonary vein
    Lee, PC
    Tai, CT
    Hsieh, MH
    Tsai, CF
    Chen, SA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2000, 23 (10): : 1561 - 1563
  • [28] Unexpected Electrical Isolation of the Superior Vena Cava During Radiofrequency Hot Balloon Ablation in the Right Superior Pulmonary Vein
    Yamasaki, Hiro
    Adachi, Toru
    Komatsu, Yuki
    Kuroki, Kenji
    Sekiguchi, Yukio
    Nogami, Akihiko
    Aonuma, Kazutaka
    CIRCULATION JOURNAL, 2017, 81 (05) : 763 - 765
  • [29] Prevalence and clinical outcome of phrenic nerve injury during superior vena cava isolation and circumferential pulmonary vein antrum isolation using radiofrequency energy
    Miyazaki, Shinsuke
    Usui, Eisuke
    Kusa, Shigeki
    Taniguchi, Hiroshi
    Ichihara, Noboru
    Takagi, Takamitsu
    Iwasawa, Jin
    Kuroi, Akio
    Nakamura, Hiroaki
    Hachiya, Hitoshi
    Hirao, Kenzo
    Iesaka, Yoshito
    AMERICAN HEART JOURNAL, 2014, 168 (06) : 846 - 853
  • [30] Novel Technique to Prevent Phrenic Nerve Injury During Pulmonary Vein Isolation Using Preprocedural Imaging
    Roka, Attila
    Heist, E. Kevin
    Refaat, Marwan
    Ruskin, Jeremy
    Mansour, Moussa
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (10) : 1057 - 1062