Distortion of Right Superior Pulmonary Vein Anatomy by Balloon Catheters as a Contributor to Phrenic Nerve Injury

被引:19
|
作者
不详
机构
[1] Department of Internal Medicine, Translational Cardiac Electrophysiology Laboratory, Division of Cardiovascular Disease, Rochester, MI
[2] Mayo Clinic/Saint Mary's Hospital, 2-416 Alfred Building, Rochester, MN 55902
关键词
ablation; atrial fibrillation; balloon catheter; phrenic nerve injury; cryoablation; INTENSITY FOCUSED ULTRASOUND; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; CRYOBALLOON; EFFICACY; COMPLICATION; SAFETY;
D O I
10.1111/j.1540-8167.2009.01495.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
RSPV Distortion by Balloon Catheter. Introduction: Cryothermal, HIFU, and laser catheter-based balloon technologies have been developed to simplify ablation for AF. Initial enthusiasm for their widespread use has been dampened by phrenic nerve (PN) injury. The interaction between PN and pulmonary vein (PV) geometry contributing to PN injury is unclear. Methods and Results: After right thoracotomy, the PN course along the epicardial right atrial surface was mapped directly in 10 dogs. The location of the PN and its relationship with the right superior (RS) PV, and potential RSPV surface distortions after balloon inflation were established by electroanatomic mapping. In 5 dogs, the PN was captured within the RSPV, but could not be stimulated in the remaining 5 dogs. The distance between the RSPV and the PN was significantly shorter in the captured group than in the noncaptured group (6.3 +/- 3.1 mm vs 10.2 +/- 3.2 mm, P < 0.001). Importantly, 96% of the captured sites within the RSPV were observed at a distance > 5 mm into the PV. The inflated balloon surface anteriorly extended 5.6 +/- 3.7 mm outside the PV diameter, with distortion of anatomy narrowing the distance from the balloon surface to the PN to 4.8 +/- 2.3 mm. (Distance of the original RSPV-to-PN: 9.4 +/- 2.7 mm, P < 0.001.) Conclusion: PN injury with balloon technologies may stem fromanatomic distortion of the PV orifice/PN relationship, through increasing contact or shortening the relative distance between the ablation site and the PN, even without displacement of the balloon into the PV. These data are important in the refinement of these technologies to improve procedural safety. (J Cardiovasc Electrophysiol, Vol. 20, pp. 1151-1157, October 2009)
引用
收藏
页码:1151 / 1157
页数:7
相关论文
共 50 条
  • [1] Distortion of Right Superior Pulmonar Vein Anatomy by Balloon Catheters as a Contributor to Phrenic Nerve Injury
    Okumura, Yasuo
    Henz, Benhur D.
    Johnson, Susan B.
    Bunch, T. J.
    Packer, Douglas L.
    CIRCULATION, 2008, 118 (18) : S587 - S587
  • [2] Right phrenic nerve injury following electrical disconnection of the right superior pulmonary vein
    Lee, BK
    Choi, KJ
    Kim, J
    Rhee, KS
    Nam, GB
    Kim, YH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (10): : 1444 - 1446
  • [3] Effect of cryoballoon inflation at the right superior pulmonary vein orifice on phrenic nerve location
    Iso, Kazuki
    Nagashima, Koichi
    Okumura, Yasuo
    Watanabe, Ichiro
    Nakai, Toshiko
    Ohkubo, Kimie
    Sonoda, Kazumasa
    Kogawa, Rikitake
    Sasaki, Naoko
    Takahashi, Keiko
    Kurokawa, Sayaka
    Nikaido, Mizuki
    Hirayama, Atsushi
    HEART RHYTHM, 2016, 13 (01) : 28 - 36
  • [4] Increased Right Superior Pulmonary Vein Ovality is Associated With Phrenic Nerve Injury in Patients Undergoing Cryoablation for Atrial Fibrillation
    Vaishnav, Aditi S.
    Coleman, Kristie M.
    Makker, Parth
    Saleh, Moussa
    Bhasin, Kabir
    Bernstein, Neil
    Skipitaris, Nicholas T.
    Mountantonakis, Stavros E.
    CIRCULATION, 2020, 142
  • [5] Left Phrenic Nerve Injury during Cryoballoon Ablation of the Left Superior Pulmonary Vein
    Andrie, Rene P.
    Schrickel, Jan W.
    Nickenig, Georg
    Lickfett, Lars
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (11): : e334 - e336
  • [6] Fluoroscopic position of the second-generation cryoballoon during ablation in the right superior pulmonary vein as a predictor of phrenic nerve injury
    Saitoh, Yukio
    Stroker, Erwin
    Irfan, Ghazala
    Mugnai, Giacomo
    Ciconte, Giuseppe
    Hunuk, Burak
    Velagic, Vedran
    Overeinder, Ingrid
    Tanaka, Kaoru
    Brugada, Pedro
    de Asmundis, Carlo
    Chierchia, Gian-Battista
    EUROPACE, 2016, 18 (08): : 1179 - 1186
  • [7] Phrenic nerve and cardiac vein anatomy characterization
    Lahm, RP
    Weinhaus, TJ
    Hill, AJ
    JOURNAL OF CARDIAC FAILURE, 2005, 11 (06) : S116 - S116
  • [8] Balloon Catheters for Pulmonary Vein Isolation
    Schmidt, Boris
    Chun, Kyoung Ryul Julian
    Metzner, Andreas
    Ouyang, Feifan
    Kuck, Karl-Heinz
    HERZ, 2008, 33 (08) : 580 - 584
  • [9] How to Pace Phrenic Nerve in Congenital Persistent Left Superior Caval Vein and Atresia of Right Superior Caval Vein?
    Santoro, Francesco
    Metzner, Andreas
    Ouyang, Feifan
    Kuck, Karl-Heinz
    Rillig, Andreas
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (02) : 282 - 283
  • [10] Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by balloon cryoablation
    Ghosh, Justin
    Sepahpour, Ali
    Chan, Kim H.
    Singarayar, Suresh
    McGuire, Mark A.
    HEART RHYTHM, 2013, 10 (05) : 646 - 652