摘要
To control the quality of Chrysosplenium alternifolium L., a simple, fast and reliable method of high-performance liquid chromatography coupled with a photodiode array detector (HPLC-PDA) was developed and validated for simultaneous quantitative determination of four bioactive polymethoxylated flavonoids, namely chrysosplenosides B and D, and chrysosplenols B and D. Separation of the four analytes was accomplished on a C18 Hypersil ODS column (5 mu m, 125 mm x 4 mm, i.d.) with an acetonitrile 10-100% (v/v) elution gradient, recorded at 345 nm. The equilibration of the methanol extracts and standard solution to 30% (v/v) of water was found to be necessary when minimizing viscosity differences between injections and the mobile phase, and thereby when minimizing distortions of analyte peaks and maximizing the resolution of critical bands of chrysosplenosides B and D. The correlation coefficients of all the calibration curves showed excellent linearity (r=0.9999) over the wide test range. The relative standard deviation of the method was less than 3.53 and 4.41% for intra- and inter-day assays, and the average recoveries were between 95.3 and 103.5%. High sensitivity was demonstrated with detection limits between 0.012 and 0.029 mu g/ml (0.24-0.58 ng). C. alternifolium was found to be a valuable source of the flavonoids with the total content ranging from 2.456 to 4.314% of dry weight, depending on harvest time and cultivation area. The total flavonoids were also determined using the pharmacopeial UV-spectrophotometric method and a notable underestimation was found in comparison to the developed HPLC method. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:771 / 777
页数:7
相关论文
共 50 条
  • [31] Simultaneous determination of ginsenosides by high-performance liquid chromatography with tandem mass spectrometry detection
    I. A. Rodin
    A. N. Stavrianidi
    A. V. Braun
    O. A. Shpigun
    E. I. Berizovskaya
    Journal of Analytical Chemistry, 2014, 69 : 1252 - 1258
  • [32] Simultaneous determination of quinolones for veterinary use by high-performance liquid chromatography with electrochemical detection
    Rodriguez Caceres, M. I.
    Guiberteau Cabanillas, A.
    Galeano Diaz, T.
    Martinez Canas, M. A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (3-4): : 398 - 402
  • [34] SIMULTANEOUS DETERMINATION OF DESFERRIOXAMINE AND FERRIOXAMINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH AMPEROMETRIC DETECTION
    GLENNON, JD
    SENIOR, AT
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 527 (02): : 481 - 489
  • [35] Simultaneous determination of methylparaben, propylparaben and thimerosal by high-performance liquid chromatography and electrochemical detection
    Kang, SH
    Kim, H
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (9-10) : 1359 - 1364
  • [36] Simultaneous determination of twelve tea catechins by high-performance liquid chromatography with electrochemical detection
    Sano, M
    Tabata, M
    Suzuki, M
    Degawa, M
    Miyase, T
    Maeda-Yamamoto, M
    ANALYST, 2001, 126 (06) : 816 - 820
  • [37] Simultaneous determination of ginsenosides by high-performance liquid chromatography with tandem mass spectrometry detection
    Rodin, I. A.
    Stavrianidi, A. N.
    Braun, A. V.
    Shpigun, O. A.
    Berizovskaya, E. I.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 69 (13) : 1252 - 1258
  • [38] SIMULTANEOUS DETERMINATION OF THIOLS AND DISULFIDES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION
    OKA, TT
    UCHIYAMA, S
    SAITO, Y
    IMAI, K
    ANALYTICA CHIMICA ACTA, 1988, 205 (1-2) : 29 - 41
  • [39] Simultaneous determination of fentanyl and midazolam using high-performance liquid chromatography with ultraviolet detection
    Portier, EJG
    de Blok, K
    Butter, JJ
    van Boxtel, CJ
    JOURNAL OF CHROMATOGRAPHY B, 1999, 723 (1-2): : 313 - 318
  • [40] Simultaneous determination of atazanavir, efavirenz and lopinavir by high-performance liquid chromatography with Uv detection
    Barassi, A.
    Pateri, F.
    Musazzi, L.
    d'Eril, G. Melzi
    CLINICAL CHEMISTRY, 2009, 55 (06) : A258 - A258