Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition

被引:452
|
作者
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
Ropers, Dieter [1 ]
Schepis, Tiziano [1 ]
Pflederer, Tobias [1 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Daniel, Werner G. [1 ]
Uder, Michael [2 ]
Lell, Michael M. [2 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
关键词
Computed tomography; Coronary CT angiography; Dual-source CT; Radiation exposure; IMAGE QUALITY; CT ANGIOGRAPHY; RADIATION-EXPOSURE; AMERICAN-COLLEGE; GUIDELINES; MANAGEMENT; REDUCTION; COMMITTEE; ANGINA; UPDATE;
D O I
10.1093/eurheartj/ehp470
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv. In 50 consecutive patients (body weight < 100 kg, sinus rhythm < 60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 x 128 x 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 +/- 20 ms. Mean dose-length product was 62 +/- 5 mGy cm, the effective dose was 0.87 +/- 0.07 mSv (0.78-0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were 'uninterpretable'. In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 50 条
  • [41] Non-Electrocardiogram-Triggered 70-kVp High-Pitch Computed Tomography Angiography of the Whole Aorta With Iterative Reconstruction: Initial Results
    Zhang, Long Jiang
    Li, Xie
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Tang, Chun Xiang
    Zhou, Chang Sheng
    Lu, Guang Ming
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (01) : 109 - 117
  • [42] Low Dose High-Pitch Spiral Acquisition 128-Slice Dual-Source Computed Tomography for the Evaluation of Coronary Artery Bypass Graft Patency
    Goetti, Robert
    Leschka, Sebastian
    Baumueller, Stephan
    Plass, Andre
    Wieser, Monika
    Desbiolles, Lotus
    Stolzmann, Paul
    Falk, Volkmar
    Marincek, Borut
    Alkadhi, Hatem
    Feuchtner, Gudrun
    INVESTIGATIVE RADIOLOGY, 2010, 45 (06) : 324 - 330
  • [43] 128-slice dual-source CT coronary angiography with prospectively electrocardiography-triggered high-pitch spiral mode: radiation dose, image quality, and diagnostic acceptability
    Matsubara, Kosuke
    Sakuda, Keita
    Nunome, Haruka
    Takata, Tadanori
    Koshida, Kichiro
    Gabata, Toshifumi
    ACTA RADIOLOGICA, 2016, 57 (01) : 25 - 32
  • [44] Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose &lt;0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction
    Schuhbaeck, Annika
    Achenbach, Stephan
    Layritz, Christian
    Eisentopf, Jasmin
    Hecker, Franziska
    Pflederer, Tobias
    Gauss, Soeren
    Rixe, Johannes
    Kalender, Willi
    Daniel, Werner G.
    Lell, Michael
    Ropers, Dieter
    EUROPEAN RADIOLOGY, 2013, 23 (03) : 597 - 606
  • [45] Saving Dose in Triple-Rule-Out Computed Tomography Examination Using a High-Pitch Dual Spiral Technique
    Sommer, Wieland H.
    Schenzle, Jan C.
    Becker, Christoph R.
    Nikolaou, Konstantin
    Graser, Anno
    Michalski, Gisela
    Neumaier, Klement
    Reiser, Maximilian F.
    Johnson, Thorsten R. C.
    INVESTIGATIVE RADIOLOGY, 2010, 45 (02) : 64 - 71
  • [46] Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography
    Zhang, Long Jiang
    Wang, Yining
    Schoepf, U. Joseph
    Meinel, Felix G.
    Bayer, Richard R., II
    Qi, Li
    Cao, Jian
    Zhou, Chang Sheng
    Zhao, Yan E.
    Li, Xie
    Bin Gong, Jian
    Jin, Zhengyu
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2016, 26 (03) : 797 - 806
  • [47] Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: Comparison of image quality and patient radiation exposure
    Smettei, Osama A.
    Sayed, Sawsan
    Al Habib, Abdullah M.
    Alharbi, Fahad
    Abazid, Rami M.
    JOURNAL OF THE SAUDI HEART ASSOCIATION, 2018, 30 (03) : 165 - 171
  • [48] Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography
    Long Jiang Zhang
    Yining Wang
    U. Joseph Schoepf
    Felix G. Meinel
    Richard R. Bayer
    Li Qi
    Jian Cao
    Chang Sheng Zhou
    Yan E Zhao
    Xie Li
    Jian Bin Gong
    Zhengyu Jin
    Guang Ming Lu
    European Radiology, 2016, 26 : 797 - 806
  • [49] Computed tomography pulmonary angiography using high-pitch dual-source scanner technology
    Al Hassan, Donya A.
    Waheed, Khawaja B.
    El Sirafy, Mohamed N.
    Khattab, Mohamad A.
    Al-Hammadi, Hassan I.
    Ibrahim, Motassem F.
    Ibrahim, Motassem F.
    Arulanantham, Zechariah J.
    SAUDI MEDICAL JOURNAL, 2019, 40 (03) : 230 - 237
  • [50] Comparison Between Prospectively Electrocardiogram-Gated High-Pitch Mode and Retrospectively Electrocardiogram- Gated Mode for Dual-Source CT Coronary Angiography
    Koplay, Mustafa
    Celik, Mahmut
    Avci, Ahmet
    Erdogana, Hasan
    Demir, Kenan
    Sivri, Mesut
    Nayman, Alaaddin
    POLISH JOURNAL OF RADIOLOGY, 2015, 80 : 561 - 568