Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition

被引:452
|
作者
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
Ropers, Dieter [1 ]
Schepis, Tiziano [1 ]
Pflederer, Tobias [1 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Daniel, Werner G. [1 ]
Uder, Michael [2 ]
Lell, Michael M. [2 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
关键词
Computed tomography; Coronary CT angiography; Dual-source CT; Radiation exposure; IMAGE QUALITY; CT ANGIOGRAPHY; RADIATION-EXPOSURE; AMERICAN-COLLEGE; GUIDELINES; MANAGEMENT; REDUCTION; COMMITTEE; ANGINA; UPDATE;
D O I
10.1093/eurheartj/ehp470
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv. In 50 consecutive patients (body weight < 100 kg, sinus rhythm < 60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 x 128 x 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 +/- 20 ms. Mean dose-length product was 62 +/- 5 mGy cm, the effective dose was 0.87 +/- 0.07 mSv (0.78-0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were 'uninterpretable'. In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 50 条
  • [31] Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction
    Wei-Hua Yin
    Bin Lu
    Zhi-Hui Hou
    Nan Li
    Lei Han
    Yong-Jian Wu
    Hong-Xia Niu
    Justin R. Silverman
    Carlo Nicola De Cecco
    U. Joseph Schoepf
    European Radiology, 2013, 23 : 2927 - 2933
  • [32] Image quality and radiation exposure of low-dose protocols for coronary CT angiography: comparison of prospectively triggered axial scanning and high-pitch spiral CT
    Seltmann, M.
    Achenbach, S.
    Goroll, T.
    Marwan, M.
    Pflederer, T.
    Ropers, D.
    Lell, M.
    Anders, K.
    Uder, M.
    Daniel, W. G.
    EUROPEAN HEART JOURNAL, 2010, 31 : 293 - 293
  • [33] Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction
    Yin, Wei-Hua
    Lu, Bin
    Hou, Zhi-Hui
    Li, Nan
    Han, Lei
    Wu, Yong-Jian
    Niu, Hong-Xia
    Silverman, Justin R.
    De Cecco, Carlo Nicola
    Schoepf, U. Joseph
    EUROPEAN RADIOLOGY, 2013, 23 (11) : 2927 - 2933
  • [34] High-Pitch Spiral Computed Tomography Effect on Image Quality and Radiation Dose in Pediatric Chest Computed Tomography
    Lell, Michael M.
    May, Matthias
    Deak, Paul
    Alibek, Sedat
    Kuefner, Michael
    Kuettner, Axel
    Koehler, Henrik
    Achenbach, Stephan
    Uder, Michael
    Radkow, Tanja
    INVESTIGATIVE RADIOLOGY, 2011, 46 (02) : 116 - 123
  • [35] Image Quality and Radiation Exposure Comparison of a Double High-Pitch Acquisition for Coronary Computed Tomography Angiography Versus Standard Retrospective Spiral Acquisition in Patients With Atrial Fibrillation
    Elias dos Prazeres, Carlos Eduardo
    Magalhaes, Tiago Augusto
    de Castro Carneiro, Adriano Camargo
    Cury, Roberto Caldeira
    Moreira, Valeria de Melo
    Silva Matsumoto Bello, Juliana Hiromi
    Rochitte, Carlos Eduardo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2018, 42 (01) : 45 - 53
  • [36] Low-Concentration Contrast Medium for 128-Slice Dual-Source CT Coronary Angiography at a Very Low Radiation Dose Using Prospectively ECG-Triggered High-Pitch Spiral Acquisition
    Zheng, Minwen
    Wu, Yongjie
    Wei, Mengqi
    Liu, Ying
    Zhao, Hongliang
    Li, Jian
    ACADEMIC RADIOLOGY, 2015, 22 (02) : 195 - 202
  • [37] Image quality and radiation dose of a prospectively electrocardiography-triggered high-pitch data acquisition strategy for coronary CT angiography: The multicenter, randomized PROTECTION IV study
    Deseive, Simon
    Pugliese, Francesca
    Meave, Aloha
    Alexanderson, Erick
    Martinoff, Stefan
    Hadamitzky, Martin
    Massberg, Steffen
    Hausleiter, Joerg
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (04) : 278 - 285
  • [38] Advanced Adaptive Axial-Sequential Prospectively Electrocardiogram-Triggered Dual-Source Coronary Computed Tomographic Angiography in a Patient With Atrial Fibrillation
    Sidhu, Manavjot S.
    Venkatesh, Vikram
    Hoffmann, Udo
    Ghoshhajra, Brian B.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (06) : 747 - 748
  • [39] High-Pitch Computed Tomography Coronary Angiography-A New Dose-Saving Algorithm: Estimation of Radiation Exposure
    Ketelsen, Dominik
    Buchgeister, Markus
    Korn, Andreas
    Fenchel, Michael
    Schmidt, Bernhard
    Flohr, Thomas G.
    Thomas, Christoph
    Schabel, Christoph
    Tsiflikas, Ilias
    Syha, Roland
    Claussen, Claus D.
    Heuschmid, Andmartin
    RADIOLOGY RESEARCH AND PRACTICE, 2012, 2012
  • [40] Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose <0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction
    Annika Schuhbaeck
    Stephan Achenbach
    Christian Layritz
    Jasmin Eisentopf
    Franziska Hecker
    Tobias Pflederer
    Soeren Gauss
    Johannes Rixe
    Willi Kalender
    Werner G. Daniel
    Michael Lell
    Dieter Ropers
    European Radiology, 2013, 23 : 597 - 606