Development of three-dimensional seismic isolation technology for next generation nuclear power plant applications

被引:0
|
作者
Takahashi, K. [1 ]
Inoue, K. [1 ]
Morishita, M. [1 ]
Fujita, T. [1 ]
机构
[1] Japan Atom Power Co, Tokyo, Japan
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic isolation technology plays an important role in the area of architect engineering, especially in Japan where earthquake comes so often. This technology also makes the nuclear power plant rationalized. The horizontal base isolation with laminated rubber bearings has already been proven its effectiveness. These days, seismic isolation technology is expected to mitigate even the vertical load, which affects the structural design of primary components. Seismic isolation system has possibility to improve the economical situation for the nuclear power plant. From these points of view, a research project has been proceeded to realize practical three dimensional seismic isolation systems from 2000 to 2005 under the sponsorship of the Ministry of Economy, Trade and Industry of the Japanese government. The isolation system is developed for the supposed "Fast Breeder Reactor (abbreviated FBR)" of the next generation. Two types of seismic isolation systems are developed in the R&D project. One is a three-dimensional base isolation for a reactor building (abbreviated 3D SIS) and the other is a vertical isolation for main components with horizontal base isolation of the reactor building (abbreviated V.+2D SIS). At first step of the R&D, requirements and targets of development for the seismic isolation system were identified. Seismic condition for R&D was discussed based on the real seismic response. Vertical natural frequency and damping ratio required to the system were introduced from the response to the seismic movement. As for 3D SIS, several system concepts were proposed to satisfy the requirements and targets. Through discussions and tests on performance, reliability, applicability, maintainability, "Rolling seal type air spring system with hydraulic anti-rocking devices" was decided to be developed. Verification shaking tests with the 1/7 scale model of the system and analysis for applicability to the real plant are conducted. The result shows that the system is able to support the reactor building, to suppress the rocking motion and to mitigate the vertical seismic load. As for V.+2D SIS, coned disk spring device was selected at the beginning of R&D. Performance tests of the elements, which include common deck movement, were conducted and the system applicability to the plant is confirmed. Verification tests were conducted with 1/8 scale model of the system and the result proves the applicability to the real plant.
引用
收藏
页码:325 / 332
页数:8
相关论文
共 50 条
  • [41] Applications of three-dimensional printing technology in urological practice
    Youssef, Ramy F.
    Spradling, Kyle
    Yoon, Renai
    Dolan, Benjamin
    Chamberlin, Joshua
    Okhunov, Zhamshid
    Clayman, Ralph
    Landman, Jaime
    BJU INTERNATIONAL, 2015, 116 (05) : 697 - 702
  • [42] The advantages and applications of three-dimensional Integral Imaging technology
    Zhang, Wenge
    Wang, Junfu
    Jiang, Xiaoyu
    Wang, Yifei
    THREE-DIMENSIONAL IMAGE ACQUISITION AND DISPLAY TECHNOLOGY AND APPLICATIONS, 2018, 10845
  • [43] Development of an innovative three-dimensional vibration isolation bearing
    Cao, Yingri
    Peng, Pan
    Wang, Haishen
    Sun, Jiangbo
    Xiao, Genqi
    Zuo, Zhengfa
    ENGINEERING STRUCTURES, 2023, 295
  • [44] Three-dimensional finite element modelling of thermal and chlorine discharges of a maritime nuclear power plant
    Marcos, F
    Janin, JM
    Teisson, C
    ENVIRONMENTAL AND COASTAL HYDRAULICS: PROTECTING THE AQUATIC HABITAT, PROCEEDINGS OF THEME B, VOLS 1 & 2, 1997, 27 : 329 - 334
  • [45] Lightning Surge Analysis of a PWR Nuclear Power Plant Using the Three-Dimensional FDTD Method
    Tatematsu, A.
    Motoyama, H.
    Tanigawa, A.
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [46] Development of three-dimensional reinforced membrane technology for high performance balloon and inflatable applications
    Lachenmeier, KS
    Murai, K
    NEXT GENERATION IN SCIENTIFIC BALLOONING, 2004, 33 (10): : 1732 - 1735
  • [47] STUDY ON SEISMIC ISOLATION AND HI-FREQUENCY VIBRATION ISOLATION TECHNOLOGY FOR EQUIPMENT IN NUCLEAR POWER PLANT USING AERO FLOATING TECHNIQUE
    Takito, Kiyotaka
    Furuya, Osamu
    Kurabayashi, Hiroshi
    Sanpei, Kunio
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING (ICONE2020), VOL 3, 2020,
  • [48] Three-dimensional periodic materials as seismic base isolator for nuclear infrastructure
    Witarto, Witarto
    Wang, S. J.
    Yang, C. Y.
    Wang, Jiaji
    Mo, Y. L.
    Chang, K. C.
    Tang, Yu
    AIP ADVANCES, 2019, 9 (04)
  • [49] Towards next generation virtual power plant: Technology review and frameworks
    Bhuiyan, Erphan A.
    Hossain, Md. Zahid
    Muyeen, S. M.
    Fahim, Shahriar Rahman
    Sarker, Subrata K.
    Das, Sajal K.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 150
  • [50] Three-Dimensional RF MEMS Switch for Power Applications
    Choi, Joo-Young
    Ruan, Jinyu
    Coccetti, Fabio
    Lucyszyn, Stepan
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (04) : 1031 - 1039