Development of three-dimensional seismic isolation technology for next generation nuclear power plant applications

被引:0
|
作者
Takahashi, K. [1 ]
Inoue, K. [1 ]
Morishita, M. [1 ]
Fujita, T. [1 ]
机构
[1] Japan Atom Power Co, Tokyo, Japan
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Seismic isolation technology plays an important role in the area of architect engineering, especially in Japan where earthquake comes so often. This technology also makes the nuclear power plant rationalized. The horizontal base isolation with laminated rubber bearings has already been proven its effectiveness. These days, seismic isolation technology is expected to mitigate even the vertical load, which affects the structural design of primary components. Seismic isolation system has possibility to improve the economical situation for the nuclear power plant. From these points of view, a research project has been proceeded to realize practical three dimensional seismic isolation systems from 2000 to 2005 under the sponsorship of the Ministry of Economy, Trade and Industry of the Japanese government. The isolation system is developed for the supposed "Fast Breeder Reactor (abbreviated FBR)" of the next generation. Two types of seismic isolation systems are developed in the R&D project. One is a three-dimensional base isolation for a reactor building (abbreviated 3D SIS) and the other is a vertical isolation for main components with horizontal base isolation of the reactor building (abbreviated V.+2D SIS). At first step of the R&D, requirements and targets of development for the seismic isolation system were identified. Seismic condition for R&D was discussed based on the real seismic response. Vertical natural frequency and damping ratio required to the system were introduced from the response to the seismic movement. As for 3D SIS, several system concepts were proposed to satisfy the requirements and targets. Through discussions and tests on performance, reliability, applicability, maintainability, "Rolling seal type air spring system with hydraulic anti-rocking devices" was decided to be developed. Verification shaking tests with the 1/7 scale model of the system and analysis for applicability to the real plant are conducted. The result shows that the system is able to support the reactor building, to suppress the rocking motion and to mitigate the vertical seismic load. As for V.+2D SIS, coned disk spring device was selected at the beginning of R&D. Performance tests of the elements, which include common deck movement, were conducted and the system applicability to the plant is confirmed. Verification tests were conducted with 1/8 scale model of the system and the result proves the applicability to the real plant.
引用
收藏
页码:325 / 332
页数:8
相关论文
共 50 条
  • [21] Study on seismic safety evaluation of crossover pipeline connecting containment and turbine building in three-dimensional isolated nuclear power plant
    Kong, Derui
    Liu, Wenguang
    Yang, Jie
    Wang, Kai
    He, Wenfu
    NUCLEAR ENGINEERING AND DESIGN, 2023, 412
  • [22] Research and application on three-dimensional seismic and vibration isolation for building
    魏陆顺
    周福霖
    谭平
    任珉
    Journal of Harbin Institute of Technology(New series), 2011, (01) : 62 - 66
  • [23] POWER CONVERSION SYSTEM EVALUATION FOR THE NEXT GENERATION NUCLEAR PLANT
    Johnson, Gregory A.
    NUCLEAR TECHNOLOGY, 2011, 175 (02) : 371 - 387
  • [24] Three-dimensional nuclear analysis of the final optics of a laser driven fusion power plant
    Sawan, M. E.
    Ibrahim, A.
    Bohm, T. D.
    Wilson, P. P. H.
    FUSION ENGINEERING AND DESIGN, 2008, 83 (10-12) : 1879 - 1883
  • [25] Theoretical and experimental study on three-dimensional base-isolated nuclear power plant
    Wang, T. (wangtao2004@gmail.com), 1600, Chinese Society of Civil Engineering (45):
  • [26] Seismic analysis of nuclear power plants by using three-dimensional finite element models: a review
    Onitsuka, Shohei
    Iijima, Tadashi
    Yamada, Tomonori
    Yoshimura, Shinobu
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2019, 56 (01) : 1 - 16
  • [27] The development of decommissioning technology for nuclear power plant
    Ogawa, N
    Saishu, S
    Ishikura, T
    HIGH-POWER LASERS IN CIVIL ENGINEERING AND ARCHITECTURE, 2000, 3887 : 78 - 93
  • [28] Development of Nuclear Power Plant Technology in Russia
    Kraemer, Juergen
    Richter, Roland
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2008, 53 (8-9): : 520 - +
  • [29] Safety assessment of the seismic resistance of nuclear power plant technology
    Kralik, Juraj
    DYNAMICS OF CIVIL ENGINEERING AND TRANSPORT STRUCTURES AND WIND ENGINEERING (DYN-WIND'2017), 2017, 107
  • [30] Concentrated Thermal Photovoltaic Power Generation Improvement Through the Use of Three-Dimensional Technology
    Mafimidiwo, Olufunmilayo Alice
    Saha, Akshay Kumar
    2019 SOUTHERN AFRICAN UNIVERSITIES POWER ENGINEERING CONFERENCE/ROBOTICS AND MECHATRONICS/PATTERN RECOGNITION ASSOCIATION OF SOUTH AFRICA (SAUPEC/ROBMECH/PRASA), 2019, : 634 - 639