Increased oxyphil cell ratio, parathyroid gland volume and weight correlate with the localisation of parathyroid adenoma on Technetium-99m MIBI scintigraphy scan

被引:0
|
作者
Durmus, E. T. [1 ]
Kefeli, M. [2 ]
Baycelebi, D. [2 ]
Atmaca, A. [1 ]
Colak, R. [1 ]
Polat, C. [3 ]
Mete, O. [4 ,5 ,6 ]
机构
[1] Ondokuz Mayis Univ, Dept Endocrinol & Metab, Samsun, Turkey
[2] Ondokuz Mayis Univ, Dept Pathol, Samsun, Turkey
[3] Ondokuz Mayis Univ, Dept Gen Surg, Samsun, Turkey
[4] Univ Hlth Network, Dept Pathol, Lab Med Program, Toronto, ON, Canada
[5] Univ Toronto, Dept Lab Med & Pathobiol, Toronto, ON, Canada
[6] Princess Margaret Canc Ctr, Endocrine Oncol Site, Toronto, ON, Canada
关键词
D O I
暂无
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
PS-22-013
引用
收藏
页码:S224 / S224
页数:1
相关论文
共 50 条
  • [41] Does an additional thyroid study improve the localisation of a parathyroid adenoma using washout Tc-99m MIBI?
    Halim, Mohamed
    Kilburn-Toppin, Fleur
    Buscombe, John
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [42] Technetium-99m sestamibi parathyroid localization is accurate enough for scan-directed unilateral neck exploration
    Borley, NR
    Collins, REC
    ODoherty, M
    Coakley, A
    BRITISH JOURNAL OF SURGERY, 1996, 83 (07) : 989 - 991
  • [43] Successful Removal of an Intrathyroidal Parathyroid Adenoma Located by Technetium Tc 99m Sestamibi Scan and Ultrasound
    Grisel, Jedidiah J.
    Al-Ghawi, Hayma
    Heubi, Christine H.
    Steward, David L.
    THYROID, 2009, 19 (04) : 423 - 425
  • [44] The efficacy of technetium-99m-MIBI scan and intraoperative methylene blue staining for the localization of abnormal parathyroid glands
    Hiroyuki Takei
    Yuichi Iino
    Keigo Endo
    Jun Horiguchi
    Michio Maemura
    Yukio Koibuchi
    Yoshio Horii
    Takao Yokoe
    Tsunehiro Ishida
    Tetsunari Oyama
    Yasuo Morishita
    Surgery Today, 1999, 29 : 307 - 312
  • [45] The efficacy of technetium-99m-MIBI scan and intraoperative methylene blue staining for the localization of abnormal parathyroid glands
    Takei, H
    Iino, Y
    Endo, K
    Horiguchi, J
    Maemura, M
    Koibuchi, Y
    Horii, Y
    Yokoe, T
    Ishida, T
    Oyama, T
    Morishita, Y
    SURGERY TODAY-THE JAPANESE JOURNAL OF SURGERY, 1999, 29 (04): : 307 - 312
  • [46] Detecting Synchronous Parathyroid Adenoma and False-Positive Findings on Technetium-99m MIBI Single Photon-Emission Computed Tomography/Computed Tomography
    Lee, Ji Young
    Song, Hee-Sung
    Choi, Jae Hyuck
    Hyun, Chang Lim
    Lee, Sang Ah
    Choi, Joon-Hyouk
    Lee, Seokjae
    DIAGNOSTICS, 2019, 9 (02):
  • [47] Single Photon Emission Computed Tomography (SPECT) Should be Routinely Performed for the Detection of Parathyroid Abnormalities Utilizing Technetium-99m Sestamibi Parathyroid Scintigraphy
    Thomas, Damita L.
    Bartel, Twyla
    Menda, Yusuf
    Howe, James
    Graham, Michael M.
    Juweid, Malik E.
    CLINICAL NUCLEAR MEDICINE, 2009, 34 (10) : 651 - 655
  • [48] TECHNIQUE AND 1ST RESULTS OF THE SUBTRACTION SCINTIGRAPHY OF THE PARATHYROID USING TL-201 AND TECHNETIUM-99M
    KRAUS, W
    WAGNER, PK
    HAHN, K
    ROTHMUND, M
    NUC COMPACT-EUROPEAN-AMERICAN COMMUNICATIONS IN NUCLEAR MEDICINE, 1984, 15 (04): : 216 - &
  • [49] SUCCESSFUL LOCALIZATION OF PARATHYROID ADENOMATA BY TL-201 AND TECHNETIUM-99M SUBTRACTION SCINTIGRAPHY - DESCRIPTION OF AN IMPROVED TECHNIQUE
    FOGELMAN, I
    MCKILLOP, JH
    BESSENT, RG
    BOYLE, IT
    GRAY, HW
    GUNN, I
    HUTCHISON, JSF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1984, 9 (12): : 545 - 547
  • [50] Successful Detection and Removal of a Functional Parathyroid Adenoma in a Pony Using Technetium Tc 99m Sestamibi Scintigraphy
    Tomlinson, J. E.
    Johnson, A. L.
    Ross, M. W.
    Engiles, J. B.
    Levine, D. G.
    Wisner, W. A.
    Sweeney, R. W.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2014, 28 (02) : 687 - 692